5-Zone Heat Pump ARCOAIRE D5CMHA | 48,000 BTU - R454B

In stock
SKU: D5CMHAH48FAK
48,000BTU/h · 5 heads
−30 °Cheats down to
$5,400LogisVert, indicative
ENERGY STAR® cold climateOptional Wi-FiR-454BUp to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit D5CMHAH48FAKPossible indoor models D5FSHAH09XAK, D5FSHAH12XAK, D5FSHAH24XAKAHRI 215357152· ENERGY STAR 3556880
In short

The Arcoaire D5CMHA 48 000 multi-zone heat pump heats and cools 5 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 45,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $5,400 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

5 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215357152
45,000BTU/h at −8 °C
−30 °Cstill heating
5heads
2.6COP at −8 °C
$5,400LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

D5CMHAH48FAK

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
234
48,000BTU
234Here
55,000BTU
2345

Arcoaire D5CMHA 48 000 · 5 zones

45,000 BTU/h
at −8 °C
$5,400
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 97 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling23.0
Scale 1 – 30
HSPF2 · seasonal heating11.3
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C2.0
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

45,000 BTU/h÷ 1,000 ×$120=$5,400

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215357152). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone5 wall units
On the wall1 outdoor unit5 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$5,400 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

24,600Still 24,600 BTU/h at −30 °CAccording to NEEP, its certified maximum capacity at −30 °C (−22 °F) is 24,600 BTU/h, 51% of its nominal 48,000 BTU size.
13,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when the load drops.
$5,400LogisVert grantAmount for the owner of an existing home, according to Hydro-Québec’s list of October 19, 2026.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTU · 4 tonsSheet
SEER2 (seasonal cooling efficiency)23.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)11.3AHRI
Heating
Capacity at −8 °C45,000 BTU/h · COP 2.6Sheet
Capacity at −15 °C47,000 BTU/h · COP 2.0Sheet
Capacity at −30 °C (max.)24,600 BTU/h · COP 1.27Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product5 ZonesSheet
Maximum zones5 ZonesSheet
Possible indoor modelsD5FSHAH09XAK, D5FSHAH12XAK, D5FSHAH24XAKSheet
Installation
Electrical
Voltage220 VSheet
RefrigerantR-454BSheet
Wi-FiEn OptionSheet
Certifications and warranty
AHRI215357152AHRI
ENERGY STARYes · cold climate · ID 3556880Sheet
LogisVert grant (indicative)$5,400Sheet
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Five rooms on a single condenser, without building ducts

A home heated with baseboards has no air ducts, and building them would mean opening ceilings, giving up closets and redoing finishes. The 5-Zone Heat Pump ARCOAIRE D5CMHA | 48,000 BTU - R454B gets around that by placing a head directly in each of the five main rooms. Its 4-ton D5CMHAH48FAK condenser serves 5 zones (up to 5 at most) and is built with the D5FSHAH09XAK, D5FSHAH12XAK and D5FSHAH24XAK wall-mounted heat pump heads. Its inverter compressor distributes its capacity among the heads that are calling.

Its ratings are 23.0 SEER2, 12.0 EER2 and 11.3 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 3556880. The certificate still lists its capacity at -30 °C, and our product sheet shows an indicative LogisVert amount of $5,400.

Who it is for: the home without ducts

This system is aimed first at homes in Montreal, Laval and Longueuil that have always been heated with electric baseboards: two-storey houses, cottages, large bungalows with a finished basement. Without ducts, the only way to heat and cool each room with a heat pump is to put a head in it. With five zones, the open area, the primary bedroom, two other bedrooms and an office or basement each get their own set point, from a single outdoor unit.

Multi-zone or central heat pump: how to decide

If the house already has ducts in good condition, a central heat pump is often the simplest solution: one indoor unit, air distributed through the existing registers. Without ducts, the comparison changes. Multi-zone avoids ductwork and gives an independent set point per room from the start, something a central system offers only with motorized dampers. On the other hand, each room served carries a head on the wall, and each head needs its maintenance. We present both options during the visit when the house lends itself to it, with their respective advantages.

Distributing five heads

Each head's code indicates its size, from the D5FSHAH09XAK to the D5FSHAH24XAK, the largest on the list. A typical distribution puts the D5FSHAH24XAK in the open ground-floor area, a D5FSHAH12XAK in the primary bedroom and D5FSHAH09XAK heads in the secondary bedrooms and the office. The real size of the rooms, their windows and the insulation decide the final choice. The total of the five heads must stay within the combinations the manufacturer allows; it is one of the most important checks in the on-site assessment at this number of zones.

Five zones on 4 tons: the sharing

Five heads share the capacity of a 4-ton condenser. This sharing works because the rooms almost never all call at full demand at the same time: the bedrooms work at night, the office by day, the open area in the evening. The condenser meters the refrigerant sent to each head according to its demand and adjusts its speed to the total. The sizing must nonetheless hold up in the most demanding scenario, a January morning when the whole house wakes up and calls for heat at once. An unoccupied bedroom kept at a reduced set point, rather than turned off, also helps the whole system stay balanced.

A condenser at its maximum

With five heads, the D5CMHAH48FAK uses all its ports. There will be no sixth zone on this condenser: every room to be served must be planned now. A utility room, a bathroom or an entrance normally keeps its baseboard, and that is perfectly fine.

The published points for winter

The certificate lists 45,000 BTU/h at -8 °C and 47,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.

  • COP of 2.60 at the -8 °C point (17 °F)
  • COP of 2.00 at the -15 °C point (5 °F)
  • Maximum capacity at -30 °C: 24,600 BTU/h, COP of 1.27
  • Heating certified down to -30 °C

At both cold points, the published value stays close to the nominal 48,000 BTU size. For a well-insulated home, this lets the heat pump carry most of the heating through the usual cold; near -30 °C, the published capacity drops and the baseboards, kept as backup, take over. These figures come from certificate AHRI 215357152, published by NEEP.

The ratings explained

The 11.3 HSPF2 measures seasonal heating efficiency, the most useful rating for a Quebec home. The 23.0 SEER2 measures seasonal cooling efficiency, and the 12.0 EER2 the efficiency on the hottest days. COP is read at a specific temperature: 2.60 at -8 °C means the heat pump delivers as heat more than two and a half times the electricity it consumes, where a baseboard delivers exactly what it consumes.

Summer, humidity and a shared mode

In summer, the compressor speeds up when several zones call for cooling, then slows down and holds the set points at low speed; these long cycles remove moisture from the air, and each head's dehumidification mode takes over on muggy days. The five heads work in the same mode at any given time, heating or cooling, each at its own temperature: in spring and fall, you choose the mode of the season and adjust the set points. The new-generation R-454B refrigerant has a global warming potential markedly lower than the fluids it replaces.

Indicative LogisVert amount: $5,400

Our product sheet shows an indicative LogisVert amount of $5,400 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.

Planning five circuits

Facade, lines, drains and electrical

Five heads means five refrigerant line sets, five communication cables and five drains. Without a plan, the facade gets covered in runs; with a plan, it shows only one or two. During the in-home assessment, we choose the walls where the lines can come down together under a finishing cover, the possible interior routes through the attic or closets, and the outlet of each drain: by gravity when the wall allows it, through a condensate pump for a basement head or one on an interior wall. The condenser goes on a solid stand or a wall bracket, above the snow line and out of the path of snow falling from the roof. It is connected to a properly sized dedicated circuit, after checking the capacity of the electrical panel. Since R-454B is mildly flammable, each connection follows its rules, followed by the leak test, the vacuum, a check of all five zones and programming the remotes with you.

Maintaining five heads

Five filters to rinse every two weeks in season: it takes a few minutes per room, and doing it on the same day for the whole house turns it into a habit. Keep the condenser clear of snow and leaves, without covering it in winter. An annual HVAC maintenance visit cleans the coils and blower wheels of all five heads, checks the drains and condensate pumps, and tightens the electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.

AirGreen, for the life of the installation

A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.

Request your free estimate for the 5-Zone Heat Pump ARCOAIRE D5CMHA | 48,000 BTU - R454B. We assess the five rooms, compare with a central solution when relevant and confirm your grant eligibility before signing.

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 45,000 BTU/h at −8 °C, 47,000 at −15 °C and 24,600 at −30 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 5 heads.

How much is the LogisVert grant?

$5,400. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3556880.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 24,600 BTU/h with a COP of 1.27.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $5,400Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.