SENVILLE R454B 2-Zone Heat Pump | 36000 BTU

Only 1 left
SKU: SENA-36HF-MOA
36,000BTU/h · 2 heads
−30 °Cheats down to
$4,560LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientWi-Fi includedR-454BUp to 5 heads
Zones
Talk to a technician · 514 316-2973
Outdoor unit SENA-36HF-MOAAHRI 215735317· ENERGY STAR 3630064
In short

The Senville R454B 36 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 38,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $4,560 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Compared with the 141 multi-zone systems of 36,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 385664AHRI 215735317LogisVert · October 1, 2026
+38,000 BTU/h at −8 °CRank 9 (tied) of 138. Class median: 27,400 BTU/h.
+$4,560 LogisVert grantRank 5 (tied) of 100. Class median: $3,480.
+HSPF2 10.7Rank 13 (tied) of 141. Class median: 10.0.
!Good to know: 65 dB(A) outdoorsRank 127 of 141; class median: 61 dB(A).
38,000BTU/h certified at −8 °C
−30 °Cstill heating
2 → 5heads, on the same unit
2.12COP at −8 °C
$4,560LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

SENA-36HF-MOA

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads and modulates from 10,000 to 38,000 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
23
27,000BTU
234
36,000BTU
Here345
48,000BTU
2345

Senville R454B 36 000 · 2 zones

38,000 BTU/h
at −8 °C
$4,560
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 100 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
10,000 → 44,000 BTU/h
-8 °C
8,000 → 38,000 BTU/h
-15 °C
7,200 → 36,000 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling23.0
Scale 1 – 30Median: 21
Rank 18 (tied) of 141 in its class.
HSPF2 · seasonal heating10.7
Scale 1 – 15Median: 10
Rank 13 (tied) of 141 in its class.
EER2 · cooling in peak heat13.0
Scale 1 – 20Median: 12
Rank 15 (tied) of 138 in its class.
COP at −15 °C2.0
Scale 0 – 4Median: 1.9
Rank 28 (tied) of 118 in its class.
ENERGY STAR Most EfficientCold climate · ID 3630064 · ENERGY STAR database
09 · LogisVert grant

A grant you can calculate, not guess.

38,000 BTU/h÷ 1,000 ×$120=$4,560

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215735317). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 141 multi-zone systems of 36,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

11 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

12 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,560 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

13 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

38.39 in
SENA-36HF-MOADepth 16.34 in
38.58 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
40 A max. breaker
MCA 37 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 1/2 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 37 A, 40 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
14 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

65
61
20 dB(A)3040506070
65 Outdoor unit61 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
15 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
10,000BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−30 °CColdest certified pointNEEP still lists 22,400 BTU/h at a COP of 1.47 at −22 °F.
150 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
16 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTUSheet
Certified cooling at 35 °C36,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)23.0AHRI
EER2 (instant cooling efficiency)13.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.7AHRI
HSPF2, region V (coldest)8.5NEEP
Heating
Capacity at +8.3 °C36,000 BTU/h · COP 4NEEP
Capacity at −8 °C38,000 BTU/h · COP 2.12NEEP
Capacity at −15 °C36,000 BTU/h · COP 2.0NEEP
Capacity at -30 °C (max.)22,400 BTU/h · COP 1.47Sheet
Modulation range10,000 – 38,000 BTU/hNEEP
Heats down to−30 °CSheet
Zones and heads
Zones on this product2 Zones (Dual Zone)Sheet
Maximum zones5 ZonesSheet
Combinations offered2 · 18 + 18 … 12 + 24Sheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)3038 CFMSheet
Installation
Outdoor unit (W × D × H)38.58 x 16.34 x 38.39 inSheet
Line sizes1/4 - 1/2 inSheet
Outdoor sound65 dB(A)Sheet
Base pan heater150 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)37 ASheet
MOP (maximum overcurrent protection)40 ASheet
RefrigerantR-454BSheet
Wi-FiIncludedSheet
Certifications and warranty
AHRI215735317AHRI
ENERGY STARYes · cold climate · ID 3630064ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$4,560LogisVert
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
17 · Description

Everything we have written about this system.

Two zones, a single outdoor compressor, and capacity designed for a true Québec winter

A 36,000 BTU 2-zone heat pump meets a very different need from a single-zone wall-mounted heat pump. It can heat and cool two distinct areas of a property from a single outdoor unit, while giving each zone its own indoor unit and temperature control.

The SENVILLE SENA-36HF-MOA R454B is particularly interesting in this category because it combines a nominal capacity of 36,000 BTU, an efficiency rating of 23 SEER2, ENERGY STAR certification, heating operation down to -30 °C, included Wi-Fi, and a multi-zone architecture that can be configured according to the building's needs. Senville documentation presents the SENA-36HF/D system as a 36,000 BTU ductless heat pump designed for multi-zone applications and ENERGY STAR certified.

For the 2-zone configuration, the manufacturer's page illustrates, among other options, an 18,000 BTU + 18,000 BTU pairing, with two indoor units powered by a single outdoor unit.

At AirGreen, this type of system is particularly relevant in Greater Montréal when a homeowner wants to replace two old air conditioners, heat two floors without installing ductwork, or better control two large zones with different heating and cooling loads.

The configuration shown includes, among other things:

  • Outdoor unit: SENA-36HF-MOA
  • Nominal cooling capacity: 36,000 BTU
  • AHRI: 215735317
  • ENERGY STAR reference: 3630064
  • SEER2: 23.0
  • EER2: 13.0
  • HSPF2 Region 4: 10.7
  • Refrigerant: R-454B
  • Heating down to -30 °C
  • Wi-Fi included
  • Power supply: 208/230 V
  • MCA: 37 A
  • MOP: 40 A
  • Outdoor sound level: 65 dB
  • Maximum outdoor airflow: approximately 3,038 CFM
  • Specified piping: 1/4 in – 1/2 in
  • Additional warranty available
  • Indicated provincial financial assistance: up to $4,560, subject to applicable eligibility conditions.

Why the 2-zone format may make more sense than two independent heat pumps

In many properties in Montréal, Laval, Longueuil, the North Shore, and the South Shore, installing two independent outdoor units is not always desirable.

Outdoor space may be limited. A condominium association may impose certain restrictions. A side façade may already contain an electrical meter, a gas line, a basement window, or a narrow passage.

A multi-zone heat pump can then connect two indoor units to a single outdoor unit.

This notably simplifies:

  • the use of the outdoor space;
  • the appearance of the installation;
  • the number of visible mechanical units;
  • certain portions of the electrical connection;
  • managing two separate spaces with a single outdoor platform.

However, it is important to understand that a multi-zone system is not simply “two heat pumps combined in one box.” The two indoor units share the available capacity of the same outdoor compressor.

This is precisely where sizing becomes important.

36,000 BTU outdoors does not necessarily mean a constant 18,000 BTU in each room

Senville documentation indicates a nominal heating capacity of 36,000 BTU/h, with a modulating range from 10,000 to 44,000 BTU/h. In cooling mode, the stated range extends from 9,000 to 43,000 BTU/h.

This modulation is one of the important features of an inverter system.

Consider a configuration with two 18,000 BTU indoor units. This does not mean that each one constantly receives exactly 18,000 BTU.

If a single zone requires a great deal of heating while the second is already close to its setpoint, the compressor can adjust its output. Conversely, when both zones simultaneously require substantial capacity, the outdoor unit must distribute what it can produce between the two indoor units.

This distinction is essential for a successful installation.

At AirGreen, we therefore seek to understand not only the total area, but also the load of each zone.

A very common layout: open ground floor and upper floor with bedrooms

In a South Shore home, for example, the ground floor may include the living room, dining room, and kitchen in one large open area, while the upper floor contains several bedrooms accessible from a hallway.

Installing an identical indoor unit on each floor may seem simple, but the needs may differ.

The ground floor may experience greater solar gains in the afternoon. The upper floor may accumulate heat in the summer. An open stairwell can allow warm air to rise and alter the balance between the two zones.

We must then take into account:

  • the location of each indoor unit;
  • natural air circulation;
  • door layout;
  • sun exposure;
  • attic insulation;
  • the area actually open to the unit;
  • the heat loss from each floor.

It is often this design work that determines whether a 2-zone heat pump will be comfortable in every room.

A 23 SEER2 rating that puts summer efficiency first

The technical documentation confirms a rating of 23 SEER2 and an EER2 of 13 for the SENA-36HF-MOA. It also indicates an HSPF2 of 10.7 for Region 4 and 8.5 for Region 5.

SEER2 represents seasonal cooling efficiency according to a standardized testing methodology.

For a homeowner who uses air conditioning extensively in Montreal or Laval, a SEER2 rating of 23 is therefore highly relevant.

However, we advise against selecting a heat pump based solely on its SEER2 rating.

An extremely efficient system on paper can lose some of its advantage if:

  • the indoor units are poorly positioned;
  • the refrigerant lines are improperly installed;
  • the system is oversized;
  • the filters are neglected;
  • a unit blows directly toward a staircase rather than toward the occupied area;
  • the drains are poorly designed;
  • the refrigerant is not managed properly during commissioning.

A heat pump’s efficiency is therefore the result of two elements: the equipment and the installation.

38,000 BTU at -8 °C: a particularly interesting figure for Montreal

The available data for this configuration indicate a heating capacity of approximately 38,000 BTU/h at -8 °C, with a COP of 2.12.

At -15 °C, the listed capacity is still approximately 36,000 BTU/h.

This data is particularly relevant in Quebec, since a heat pump is not evaluated only during the mild temperatures of fall. Its performance at -8 °C and -15 °C provides a much more useful indication of what it can deliver during a significant portion of the heating season.

A system capable of maintaining a large portion of its rated capacity at these temperatures can further reduce reliance on backup heating, provided it has been properly sized for the building.

At -30 °C, capacity decreases: this must be taken into account

The SENVILLE is advertised as continuing to provide heating down to -30 °C, which is also confirmed in the manufacturer’s documentation.

At this extreme temperature, the data provided for the configuration indicate:

  • heating capacity: approximately 22,400 BTU/h
  • COP: approximately 1.47

This figure deserves more attention than the simple statement “heating down to -30 °C.”

A 36,000 BTU heat pump therefore does not necessarily produce 36,000 BTU when the outdoor temperature reaches -30 °C.

If a home loses, for example, 35,000 BTU/h at this temperature and the heat pump provides approximately 22,400, the difference must be supplied by another heating source.

Depending on the property, this may include:

  • electric baseboard heaters;
  • an existing furnace;
  • convector heaters;
  • another backup system.

At AirGreen, we prefer to explain this reality when selecting the system rather than creating the impression that a minimum operating temperature automatically represents full rated capacity.

COP of 2.12 at -8°C: what this means in simple terms

A COP of 2.12 means that, at the corresponding temperature condition, the heat pump can provide approximately 2.12 units of heat for each unit of electricity consumed by the heat-pumping process.

At -30°C, the indicated COP drops to 1,47.

This is normal: the lower the outdoor temperature drops, the more difficult it becomes to extract heat from outside and transfer it indoors.

Actual performance may also vary depending on:

  • defrost cycles;
  • the requested indoor temperature;
  • the number of active zones;
  • the length of the lines;
  • compressor modulation;
  • outdoor conditions;
  • the condition of the filters and coils.

A true cold-climate heat pump

The configuration is listed as COLD CLIMATE: Yes, and Senville’s documentation also presents the system as optimized for cold climates, with heating maintained down to -22°F, or -30°C.

This clearly distinguishes it from a model that can operate only down to -15°C or -20°C.

For a property in Longueuil, Terrebonne, Laval, Boucherville, Repentigny, or Montréal, this operating range corresponds much better to the use we expect from a heat pump used as the primary heating source for a large part of the winter.

An ENERGY STAR certification and a specific AHRI number

The SENA-36HF-MOA is listed as ENERGY STAR, with reference 3630064 and AHRI number 215735317.

The brochure also explicitly mentions the system’s ENERGY STAR certification and AHRI certification.

The AHRI number is important because it identifies a certified combination rather than merely a product family.

When we prepare an installation involving financial assistance, we must ensure that the installed equipment matches the eligible pairing.

Up to $4,560 in indicated provincial grants

The AirGreen sheet indicates a $4,560 provincial grant for this configuration.

This amount can make comparison with less efficient systems particularly worthwhile.

However, a grant amount should never be considered automatically guaranteed. Programs may impose conditions related in particular to:

  • the building;
  • the system type;
  • the AHRI number;
  • the certification;
  • the installation date;
  • the contractor;
  • the required documentation;
  • the criteria in effect at the time of the application.

We therefore always recommend confirming actual eligibility before calculating a project’s net cost.

An outdoor unit weighing more than 200 lb: the location must be properly prepared

The outdoor unit measures 38.58 in × 16.34 in × 38.39 in and weighs approximately 211.86 lb. The manufacturer also specifies a maximum outdoor airflow of 3,037.2 CFM and a sound level of 65 dB.

This is therefore not a small outdoor unit.

For an installation in Montreal or Longueuil, where side passages can be narrow, we must measure the location before delivery.

On the North Shore or South Shore, space is often more generous, but other constraints arise: snow accumulation, terrain slope, terrace, bedroom windows, or neighboring properties.

A proper outdoor installation must include:

  • a stable base;
  • sufficient height above the snow;
  • adequate clearance around the heat exchanger;
  • access for maintenance;
  • a logical route for both piping sets;
  • proper drain management;
  • a location that avoids unnecessarily directing noise toward a bedroom or neighboring terrace.

65 dB outdoors: how to interpret the sound level

The manufacturer specifies 65 dB for the outdoor unit.

This value must be considered when choosing the location.

A unit installed against a bedroom wall, beneath a window, or in a narrow passage between two buildings may be perceived differently from a unit placed in an open area.

Reflective surfaces can also affect how sound is perceived.

At AirGreen, choosing the outdoor location is therefore part of the design, not just a matter of aesthetics.

MCA 37 A and maximum protection of 40 A

The technical data sheet states:

  • power supply: 208/230 V, single-phase, 60 Hz
  • voltage range: 187 to 253 V
  • MCA: 37 A
  • maximum protection: 40 A.

This information must be verified before installation.

In an older Montreal home equipped with a 100 A panel, for example, we do not assume that a new heat pump circuit can simply be added without analysis.

The available capacity at the electrical panel, existing loads, and the project’s electrical requirements must be verified.

R-454B: another generation of refrigerant

The system uses R-454B.

The documentation indicates a charge of 134.04 oz and specifies that the unit is precharged for up to 125 ft of refrigerant line.

This substantial precharge is particularly relevant for a multi-zone heat pump, since two indoor units may require separate piping runs.

However, “precharged for 125 ft” should not be interpreted as authorization to install any length or configuration without respecting the manufacturer’s specified limits.

Each branch must be properly designed, with the appropriate diameters and a compliant installation.

Why piping matters even more on a two-zone system

The configuration specifies 1/4 in – 1/2 in piping.

On a two-zone system, we must manage two separate refrigerant lines from the outdoor unit.

In a duplex, a two-story house, or a property with one indoor unit at the front and the other at the back, the lengths can become substantial.

A clean installation notably requires:

  1. a well-planned route before drilling;
  2. an appropriate slope for gravity drains;
  3. mechanical protection for the lines;
  4. properly executed refrigerant connections;
  5. a proper vacuum before commissioning;
  6. a leak-tightness check;
  7. an exterior finish that remains accessible for servicing.

An error on a single branch can affect the comfort of one zone and complicate future troubleshooting.

Two zones do not mean simultaneous heating and cooling

This is a common question with multi-zone heat pumps.

Indoor units connected to the same outdoor unit generally need to operate in a compatible mode. In other words, you should not expect to heat one zone significantly while the other is simultaneously providing cooling.

In a typical residence, this is generally not a problem.

However, in a property with very different orientations, a large sun-exposed sunroom, and a cold north-facing room, this point can become important during the shoulder seasons.

We take this into account before recommending a multi-zone configuration.

Wi-Fi included and Alexa integration

The SENA-36HF-MOA includes smart control features.

The documentation indicates app control, Alexa compatibility, and the ability to schedule the system and manage comfort remotely.

The manufacturer also lists an Alexa USB kit, wireless remote controls, and communication wiring among the included components.

In a two-zone installation, this feature is more useful than in multiple single-zone systems, because the homeowner can manage the two spaces separately without having to go to each unit.

Automatic vertical and horizontal louvers

The AirGreen configuration indicates:

  • vertical louvers: automatic
  • horizontal louvers: automatic

This allows the airflow to be directed more effectively in a large room.

However, the unit’s location remains crucial. Even with motorized oscillation, a unit installed too close to a wall, directly in front of a staircase, or in a poorly chosen corner will not distribute air as effectively as a unit positioned after analyzing the room.

Integrated diagnostics and leak detection

Senville documentation mentions an integrated diagnostic and leak-detection system, with monitoring capable of alerting the user to a problem, particularly one related to refrigerant.

These functions can speed up the identification of certain anomalies, but they do not replace a technical diagnosis.

An error code often helps identify a group of problems; it does not necessarily indicate which part needs to be replaced.

At AirGreen, we use diagnostic information as a starting point, then verify the system’s actual conditions.

“Up to 1,800 sq. ft.”: a marketing indication, not a sizing method

Senville documentation indicates that the system can cover up to 1,800 sq. ft.

We recommend treating this figure with caution.

A recently built 1,800 sq. ft. home on the South Shore and a century-old 1,800 sq. ft. home in Montreal can have completely different heat losses.

Even the distribution of the 1,800 sq. ft. changes the result.

An open bungalow does not perform the same way as a three-story house with several enclosed bedrooms.

We therefore use area as one piece of data among several others, never as the sole sizing criterion.

AirGreen Installation: how to turn a good specification sheet into true comfort in two zones

The choice of the two indoor units is just as important as that of the outdoor compressor

The system documentation indicates that it can support 2 to 5 zones, depending on the configuration.

In the application discussed here, we are referring to a two-zone configuration.

The manufacturer offers, among other options, an 18,000 + 18,000 BTU combination, but the right combination must be adapted to the building.

Two zones of similar area do not always require the same indoor unit.

A large open room with a cathedral ceiling may have a higher load than a floor of comparable area with several well-insulated bedrooms.

The distribution must therefore be decided before ordering.

The mistake we want to avoid: choosing the heads based solely on square footage

Suppose that two zones are each 800 sq. ft.

It would be tempting to conclude that they require the same capacity.

But the first may have:

  • large patio doors;
  • a 12-foot ceiling;
  • a southwest-facing orientation;
  • an open kitchen;
  • more air infiltration.

The second may include rooms with small windows and standard-height ceilings.

The number of square feet is the same, but the load is not.

That is why we assess the building’s actual conditions before choosing the distribution of the indoor units.

The drains can be more complicated than the refrigerant lines

On a wall-mounted heat pump, each indoor unit produces condensation in cooling mode.

With two zones, we therefore have two drains to manage.

When a natural slope toward the outside is available, drainage remains relatively simple. When the unit must be installed on an interior wall or in a configuration where gravity is insufficient, a condensate pump may be required.

At AirGreen, we try to account for this aspect during the estimate because poor drainage can lead to:

  • water leaks;
  • pump noise;
  • marks on the wall;
  • additional maintenance;
  • system shutdowns if a safety device is triggered.

Warranty

This system is covered for 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor, with the option of additional coverage.

Professional installation is required to maintain full warranty coverage and the expected performance.

Simple maintenance, but two indoor units to monitor

One of the advantages of a ductless heat pump is the absence of a central network to maintain.

However, this does not mean “zero maintenance.”

Each indoor unit has its own filters and heat exchanger.

To maintain good performance, we particularly recommend:

  • to clean the filters regularly;
  • to monitor dust buildup in the blower wheels;
  • to keep the air inlets and outlets clear;
  • to check the drains;
  • to avoid blocking the outdoor unit with objects or vegetation;
  • to keep the outdoor unit clear of snow;
  • to have the indoor units thoroughly cleaned when dirt buildup warrants it.

In a two-zone system, a very dirty unit may operate less efficiently than the other and give the impression that the system is distributing its capacity poorly.

When this SENVILLE 36,000 BTU 2-zone system is an excellent candidate

The SENVILLE SENA-36HF-MOA R454B is particularly worth considering when a homeowner wants to:

  • heat and cool two large zones with a single outdoor unit;
  • get a heat pump that operates down to -30 °C;
  • take advantage of a 23 SEER2 rating;
  • maintain strong heating capacity at -8 °C and -15 °C;
  • benefit from an ENERGY STAR system;
  • get the included Wi-Fi control;
  • reduce the number of outdoor units;
  • take advantage, if eligible, of financial assistance of up to 4 560 $.

It is particularly well suited to projects where the two zones can operate in a complementary manner and where the placement of the indoor units allows for good air distribution.

When we would consider another configuration

We might recommend a different approach if:

  • the two zones have extremely different needs;
  • they frequently need to operate in opposite modes;
  • a single indoor unit cannot properly distribute air throughout a divided zone;
  • the actual total load exceeds what the system can provide during extreme cold;
  • the distance or line-set configuration makes the installation excessively complicated;
  • two independent outdoor units would provide greater flexibility for the project.

The best system is therefore not necessarily the one with the highest BTU rating. It is the one whose design matches the building.

Why have AirGreen install this 2-zone heat pump

At AirGreen Climatisation & Chauffage, we do not reduce a multi-zone installation to choosing a location for two wall-mounted units.

We analyze the entire project:

  • capacity of each zone;
  • solar exposure;
  • air circulation;
  • ceiling height;
  • indoor unit placement;
  • line-set length;
  • drainage;
  • electrical supply;
  • outdoor location;
  • snow management;
  • noise level;
  • future accessibility for servicing.

This approach is especially important with a 36,000 BTU 2-zone heat pump, since both spaces depend on the same outdoor unit.

A well-designed configuration lets you take advantage of inverter modulation, heating down to -30 °C, 23 SEER2, and individual zone control. Conversely, poor placement of the indoor units can reduce comfort despite very appealing technical specifications.

Get an AirGreen quote for the SENVILLE 2-Zone R454B 36,000 BTU

Are you considering a SENVILLE 2-zone 36,000 BTU heat pump for a house, condo, duplex, or business?

Contact AirGreen for an assessment of your project. We can verify the required capacity for each zone, the location of the units, the line-set routing, drainage, electrical supply, and eligibility for applicable financial assistance programs.

We install and service multi-zone heat pumps in Montreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie, with particular attention to sizing and commissioning quality.

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.

18 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 38,000 BTU/h at −8 °C, 36,000 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 2 heads.

Can I mix head sizes?

Yes. The “Zones” menu offers 2 combinations, from 18 + 18 to 12 + 24 (in thousands of BTU). Each head is sized for its room.

How much is the LogisVert grant?

$4,560 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3630064. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −30 °C.

Is it noisy?

Outdoors, 65 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,560AHRI 215735317 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 385664 (AHRI 215735317): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 3630064.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.