4-Zone Heat Pump ARCOAIRE D5CMHA | 36,000 BTU - R454B
The Arcoaire D5CMHA 36 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 38,000 BTU/h at −8 °C, heats down to −30 °C and qualifies for a $4,560 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 4 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 100 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
What is particular about this machine.
Only facts published by ENERGY STAR, NEEP or the manufacturer.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
The whole family, each at their own temperature
In a two-storey family home, nobody wants the same temperature at the same time: the children sleep warm, the parents prefer a cool bedroom, and the open ground-floor area has to stay comfortable from breakfast to dinner. The 4-Zone Heat Pump ARCOAIRE D5CMHA | 36,000 BTU - R454B gives each of these rooms its own head. Its 3-ton D5CMHAH36EAK condenser serves 4 zones (up to 4 at most) and is built with the D5FSHAH09XAK, D5FSHAH12XAK and D5FSHAH18XAK wall-mounted heat pump heads.
Its ratings are 23.1 SEER2, 13.1 EER2 and 10.7 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 3620813. The certificate still lists its capacity at -30 °C, and our product sheet shows an indicative LogisVert amount of $4,560.
Two floors, four zones: the typical layout
The most frequent layout has one zone on the ground floor, where the living room, dining room and kitchen form one large room, and three zones upstairs: the primary bedroom and two children's bedrooms. This 3-ton size suits homes where that open area is generous or heavily glazed, or where the house predates current insulation standards. In a recent home with more compact rooms, the on-site assessment may instead point to a smaller condenser; we measure before deciding.
Why the upper floor and the ground floor are not set the same way
Warm air rises. In winter, part of the ground floor's heat reaches the upper floor through the stairwell, and the bedrooms often need less than expected. In summer, it is the reverse: the heat from the roof and the heat rising from below add up, and the bedrooms become the most demanding zone. With one head per room, each floor follows its own logic instead of enduring the other's. In practice, we recommend a steady set point on the ground floor and bedroom set points adjusted to the season, rather than large daily swings.
Baseboards and heat pump: who does what
The electric baseboards stay in place, but their role changes. For the heat pump to take on most of the heating, each baseboard thermostat is set a few degrees below the set point of the head in the same room: the head heats first, and the baseboard only turns on if the heat pump can no longer keep up, during deep cold. It is a simple adjustment that we make with you at commissioning. Rooms without a head, such as the bathroom, keep their usual heating.
Choosing the four heads
Each head's code indicates its size, from the D5FSHAH09XAK to the D5FSHAH18XAK, the largest on the list. A common combination: the D5FSHAH18XAK in the open area, a D5FSHAH12XAK in the primary bedroom and a D5FSHAH09XAK in each child's bedroom. The total must stay within the combinations the manufacturer allows for this condenser. A head too large for a small bedroom does not make it more comfortable: it reaches the set point too quickly, cycles more and leaves the air more humid.
Four ports out of four
With four zones, the D5CMHAH36EAK is at its maximum: no fifth head can be added. If a finished basement is part of your plans, it has to be planned now, either by including it among the four zones or by choosing another configuration. It is one of the questions we ask during the visit.
January cold, according to the certificate
The certificate lists 38,000 BTU/h at -8 °C and 36,000 BTU/h at -15 °C. The two points are measured separately; we report each one as published.
- COP of 2.12 at the -8 °C point
- COP of 2.00 at the -15 °C point
- Maximum capacity at -30 °C: 22,400 BTU/h, COP of 1.47
- Heating certified down to -30 °C
At -8 °C (17 °F), the published value exceeds the nominal 36,000 BTU size, and at -15 °C (5 °F) it matches it. For a home in the Montreal area, that covers the usual cold with all four zones running; near -30 °C, capacity drops and the baseboards take over as planned. These figures come from certificate AHRI 215357147, published by NEEP.
Cooling: the upper floor first
On July evenings, the bedrooms give the system the most work. The inverter compressor speeds up when the three upstairs heads call at the same time, then drops back to low speed to hold the set points all night. These long cycles remove moisture from the air, and the dehumidification mode takes over on muggy days. The four heads work in the same mode at any given time, heating or cooling, each at its own temperature. The new-generation R-454B refrigerant has a global warming potential markedly lower than the fluids it replaces.
The ratings, one by one
The 23.1 SEER2 measures cooling efficiency over a full season. The 13.1 EER2 measures it in the hottest condition, that of bedrooms under the roof in a heat wave. The 10.7 HSPF2 sums up heating, the season that weighs most on the bill in Quebec. Finally, COP gives the efficiency at a specific temperature: at 2.12, each kilowatt-hour consumed at -8 °C delivers a little more than double in heat.
Indicative LogisVert amount: $4,560
Our product sheet shows an indicative LogisVert amount of $4,560 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
An installation designed for a lived-in home
The job
After the in-home assessment, we draw the route for the four refrigerant line sets, the four communication cables and the four drains. The lines from the three bedrooms usually come down the same exterior wall, grouped under a finishing cover, so that only one run shows on the facade. The drains flow by gravity or, when the route requires it, through a condensate pump. The condenser goes on a stand or a wall bracket, above the snow line and out of the path of snow falling from the roof, and it is connected to a dedicated circuit after checking the electrical panel. Commissioning includes the leak test, the vacuum, a check of all four zones, programming the remotes and setting the baseboard thermostats with you.
Maintenance
Rinse the four filters every two weeks in season; allow a few minutes per room, the time to open the front panel, remove the filter, rinse it and let it dry. Keep the condenser clear of snow and leaves, and do not cover it in winter. An annual HVAC maintenance visit cleans the coils and blower wheels, checks the drains and tightens the electrical connections. In winter, white vapour during defrost and a short pause in heating are normal. Our cleaning service takes over when you prefer to hand off the annual visit.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the 4-Zone Heat Pump ARCOAIRE D5CMHA | 36,000 BTU - R454B. We assess every room in the house, choose the four heads and confirm your grant eligibility before signing.
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 38,000 BTU/h at −8 °C, 36,000 at −15 °C and 22,400 at −30 °C.
How many heads can I connect?
Up to 4 on this outdoor unit. This product is configured for 4 heads.
How much is the LogisVert grant?
$4,560. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 3620813.
Down to what temperature does it heat?
Down to −30 °C. At −30 °C, it still delivers 22,400 BTU/h with a COP of 1.47.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.