ArcoAire DLCMRA heat pump | 2-Zones | 36,000 BTU compressor

In stock
SKU: DLCMRAH36DAK-99
36,000BTU/h · 2 heads
−30 °Cheats down to
Wi-Fi includedR-410AUp to 4 heads
Areas
Talk to a technician · 514 316-2973
Outdoor unit DLCMRAH36DAKPossible indoor models DLFEHAH09XAK, DLFEHAH12XAK, DLFEHAH18XAK, DLFEHAH24XAKAHRI 201835526
In short

The ArcoAire DLCMRA 36 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 23,600 BTU/h at −8 °C, heats down to −30 °C. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Compared with the 141 multi-zone systems of 36,000 BTU we sell. Figures come from the manufacturer’s data and the AHRI certification.

AHRI 201835526
+Heats down to −30 °CRank 13 (tied) of 141. Class median: −25 °C.
!Good to know: COP 1.80 at −15 °CRank 107 of 118; class median: 1.90.
23,600BTU/h at −8 °C
−30 °Cstill heating
2 → 4heads, on the same unit
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

DLCMRAH36DAK

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones
18,000BTU
2
27,000BTU
23
36,000BTU
Here34
48,000BTU
2345

ArcoAire DLCMRA 36 000 · 2 zones

23,600 BTU/h
at −8 °C

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 72 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling21.4
Scale 1 – 30Median: 21
Rank 68 (tied) of 141 in its class.
HSPF2 · seasonal heating8.6
Scale 1 – 15Median: 10
Rank 109 (tied) of 141 in its class.
EER2 · cooling in peak heat10.5
Scale 1 – 20Median: 12
Rank 121 (tied) of 138 in its class.
COP at −15 °C1.8
Scale 0 – 4Median: 1.9
Rank 107 (tied) of 118 in its class.
09 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 141 multi-zone systems of 36,000 BTU we sell. Weaknesses too, said plainly.

10 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

11 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVertPer the listDepends on each model

We compare both options on your floor plan during the estimate.

12 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

31.88 in
DLCMRAH36DAKDepth 17.91 in
41.22 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 30 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 1/2 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 30 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up.
13 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

34
43
62
28
61
20 dB(A)3040506070
34 Reference head, lowest speed43 Reference head, highest speed28 Class indoor median62 Outdoor unit61 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
14 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTU · 3 tonsSheet
SEER2 (seasonal cooling efficiency)21.4AHRI
EER2 (instant cooling efficiency)10.5AHRI
HSPF2 (seasonal heating efficiency, region IV)8.6AHRI
Dehumidification3.38 pints/hSheet
Heating
Capacity at −8 °C23,600 BTU/hSheet
Capacity at −15 °C26,200 BTU/h · COP 1.8Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product2 Zones (Dual Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsDLFEHAH09XAK, DLFEHAH12XAK, DLFEHAH18XAK, DLFEHAH24XAKSheet
Combinations offered10 · 9 + 9 … 24 + 24Sheet
Indoor dimensions (W × D × H)32 × 7.75 × 11.81 inSheet
Vertical louversManualSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)34 – 43 dB(A)Sheet
Installation
Outdoor unit (W × D × H)41.22 x 17.91 x 31.88 inSheet
Line sizes1/4 - 1/2 inSheet
Outdoor sound62 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)30 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-410ASheet
Wi-FiIncludedSheet
Certifications and warranty
AHRI201835526AHRI
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 0 yrsSheet
AirGreen extended warrantyPossibleSheet
15 · Official brochures

The manufacturer’s documentation, as PDF.

16 · Description

Everything we have written about this system.

ArcoAire DLCMRA Heat Pump | 2-Zones | 36,000 BTU Compressor

An Innovative Solution for Lasting Comfort

At AirGreen, your well-being and satisfaction are at the heart of our concerns. Recognized specialists in the HVAC (Heating, Ventilation, and Air Conditioning) field in Montreal, Laval, Longueuil, the North Shore, and the South Shore, we are proud to introduce the ArcoAire DLCMRA wall-mounted 2-zone heat pump, a cutting-edge solution for optimal temperature regulation in your home.

Exceptional Features

The ArcoAire DLCMRA heat pump stands out for its unparalleled performance and advanced technology. Equipped with a 36,000 BTU compressor, it provides an equivalent cooling capacity, ensuring pleasant coolness even on the hottest days. Its ability to deliver efficient heating down to -30°C guarantees uninterrupted comfort throughout the year, regardless of weather conditions.

Flexibility and Adaptability

Designed to meet the specific needs of each household, this dual-zone heat pump can be expanded up to four zones, thus offering complete customization of your comfort experience. The compact exterior dimensions allow for discreet installation adaptable to any space.

Economic and Ecological Benefits

Despite the lack of federal subsidies, the ArcoAire DLCMRA heat pump is eligible for a provincial subsidy of $1,180, a significant advantage to lighten your initial investment. Although not Energy Star® certified, its 21.4 SEER efficiency rating reflects remarkable energy efficiency, significantly reducing your carbon footprint and electricity bills.

Comfort and Control at Your Fingertips

WiFi integration allows you to manage your heating and cooling system remotely, via your smartphone or tablet, for a welcoming home upon your return, without energy waste. The reduced sound pressure level at 62.0 dB(A) ensures a peaceful and quiet atmosphere, for increased well-being.

Installation and Warranty

Installation of the wall-mounted 2-zone heat pump by our expert technicians ensures efficient and standard-compliant service. With a 10-year warranty on the compressor and parts, and an optional all-inclusive additional warranty, you enjoy total peace of mind.

Why Choose AirGreen?

Our commitment to excellence and our HVAC expertise allow us to offer tailor-made solutions, suited to your needs and budget. Our customer-centric approach guarantees a hassle-free experience, from initial consultation to installation and after-sales service.

In Conclusion

The ArcoAire DLCMRA wall-mounted 2-zone heat pump represents the ideal investment for those seeking an efficient, economical, and environmentally friendly heating and cooling solution. At AirGreen, we are at your disposal to make your comfort a lasting reality.

17 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 23,600 BTU/h at −8 °C, 26,200 at −15 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 2 heads.

Can I mix head sizes?

Yes. The “Zones” menu offers 10 combinations, from 9 + 9 to 24 + 24 (in thousands of BTU). Each head is sized for its room.

Down to what temperature does it heat?

Down to −30 °C.

Is it noisy?

Indoors, the reference head goes down to 34 dB(A). Outdoors, 62 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts; labour is not included by the manufacturer. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.