PTAC Heat Pump DURASTAR | 9,000 BTU - R32
Is it the right size for this room?
Durastar publishes a 350 to 400 sq ft range for this unit. Choose your room's area.
It's the right size.
For a 350 to 450 sq ft room, this is the range Durastar publishes for this unit: 9,200 BTU/h of cooling, 7,800 BTU/h of heat-pump heating and a heater of up to 3,500 W when the cold calls for it.
Application range published by Durastar for each capacity in the lineup. Our estimator confirms the exact area on site.
What it does, in numbers
$16.02
Cooling, all summer
Less than a 60 W light bulb
Bulbs left on day and night for a year. Cooling: 5 h a day for 40 days, the assumption used by Hydro-Québec's air-conditioning calculator. Same calculation for every line: wattage × hours × 11.142 ¢/kWh.
≈$276
Heating, all winter
≈ $23 less than baseboard heaters
Typical 375 sq ft room with one exterior wall, in Montréal: 2,679 kWh of heat per winter (Environment Canada 1991–2020 climate normals). The heat pump is counted only at 8 °C and warmer, where Durastar rates its output; below that, the heater, at the price of a baseboard. If it keeps heating in colder weather, the bill goes down.
≈ $292 for the year, before tax. Winter is 95% of it. If your home stays in the first tier of Rate D in summer (7.065 ¢/kWh), cooling drops to $10.16.
Capacities and currents: Durastar PTAC/PTHP R-32 submittal, form V1.1_0324 (March 2024). Power draw: 719 W in cooling (9,200 BTU/h ÷ EER 12.8), 600 W in heat-pump mode, 3,500 W on the 3.5 kW heater. Hydro-Québec Rate D in effect since April 1, 2026: 11.142 ¢/kWh second tier, before tax.
What you should know about this one
Published, verifiable facts, not brochure claims.
9,200What it really delivers in cooling
The name says 9,000 BTU: that's the unit's size class. Durastar publishes 9,200 BTU/h at 230 V, a little more than its size class, and 9,100 at 208 V, the supply in many buildings.
3,500 WThe heater that takes over
The "35" in DRPTHP09Y32351A means a 3.5 kW heater: 3,500 W (10,900 BTU/h) at 230 V, 2,897 W at 208 V, on the 6-20P plug of the LCDI cord supplied. It heats when the heat pump can no longer keep up.
3.8The COP published at 8 °C
Durastar publishes a heat-pump COP of 3.8: 7,800 BTU/h of heat at 230 V. Each kWh you pay for gives back 3.8 in heat, against 1 for the heater or a baseboard.
4 °CBelow 4 °C, the heater takes over
Durastar's manual states it is normal for the heat pump not to run below 40 °F (4 °C) outside: the heater then heats the room. The two never run at the same time.
52 dBThe noise at low speed
52 dB(A) at low speed, 52.5 at high speed, as published by Durastar. In a bedroom, that's the number that decides the complaints: the unit runs at night, two metres from the bed.
1Pints of water it removes per hour
The dehumidification Durastar publishes in cooling mode: 1 pint per hour. It's what keeps a room comfortable in summer without it turning clammy.
61 cfmFresh air through the vent
With the vent open, Durastar publishes 61 cfm of outside air at high speed. Close it to keep all the heat or the cool air in the room.
0 °CRoom freeze protection
In an unoccupied room, Durastar provides automatic freeze protection at 32 °F (0 °C): the fan and the heater restart on their own.
It fits the standard wall sleeve
Durastar designs this PTAC for the standard 42 × 16 in wall sleeve; the sleeve and grille are sold separately. Our estimator checks the ones in place before ordering.
What it needs on site
In a replacement, we check the outlet and the breaker first: they set the heater size you can use. Our estimator confirms the sleeve, the outlet and the slope before ordering.
Complete spec sheetData and cited sources
- Model
- DRPTHP09Y32351A
- Cooling capacity (208/230 V)
- 9,100 / 9,200 BTU/h
- Heating capacity, heat pump (208/230 V)
- 7,500 / 7,800 BTU/h
- Electric heater
- 3.5 kW (2,897 / 3,500 W at 208/230 V)
- EER
- 12.8
- COP (heat pump, 8 °C)
- 3.8
- Current — cooling (208/230 V)
- 4 / 3.7 A
- Current — heat-pump heating (208/230 V)
- 3.6 / 3.4 A
- Power — cooling (208/230 V)
- 710 / 720 W
- Power — heat pump (230 V)
- 600 W
- Airflow (low/high)
- 343 / 424 cfm
- Sound level (low/high)
- 52 / 52.5 dB(A)
- Dehumidification
- 1 pints/h
- Published cooling area
- 350 to 400 sq ft
- Dimensions
- 42 × 21 × 16 in (W × D × H)
- Net weight
- 104.7 lb
- Refrigerant
- R-32 · 22.6 oz
- Heat pump → heater
- below 40 °F (4 °C) outside
- Power supply
- 208/230 V · 1 ph · 60 Hz
- Spec sheet (French)
- Spec sheet (English)
All values: Durastar PTAC/PTHP R-32 submittal, form V1.1_0324 (March 2024). Operating cost: cooling at 719 W for 200 h per summer; heating estimated for a typical 375 sq ft room (2,679 kWh of heat per winter, heat pump counted at 8 °C and warmer); at Hydro-Québec's Rate D second tier (11.142 ¢/kWh), in effect since April 1, 2026.
The neighbouring models
Talk to an HVAC technician before you choose
We check the existing sleeve, the outlet and the heater size, and give you an installed price. For a building, we order the same series for every room.
Une chambre occupée à l'année ne se calcule pas comme une chambre d'été
Dans une résidence intermédiaire de Chambly, les chambres ne se libèrent pas : la même personne y vit toute l'année, et depuis que le travail à distance s'y est installé, certaines sont occupées du lever au coucher. Une chambre habitée en continu accumule la chaleur des appareils et des occupants d'une façon qu'un calcul de surface ne montre pas. La Thermopompe PTAC DURASTAR | 9 000 BTU - R32 se dimensionne sur cette charge réelle, chambre par chambre.
DuraStar ne publie pas de certificat AHRI pour cet appareil ; les valeurs ci-dessous sont celles de sa fiche technique. Ce monobloc n'est pas admissible aux programmes d'aide d'Hydro-Québec, ce qui explique le 0 $ de la fiche.
Le 9 000 BTU en chiffres publiés
- Capacité nominale : 9 000 BTU/h
- Réfrigérant : R-32
- Alimentation : 220 V, sur circuit dédié
- Niveau sonore intérieur : 52,0 et 52,5 dB(A)
- Caisson : 42 x 21 x 16 po, modèle DRPTHP09Y32351A
La charge réelle d'une chambre habitée jour et nuit
Notre règle de départ retient environ 18 000 BTU/h par 1 000 pieds carrés, ajustée selon l'isolation, la fenestration, la hauteur des plafonds et l'ouverture entre les pièces. Elle donne un ordre de grandeur, pas une réponse : une chambre d'angle avec un poste de travail à la fenêtre sort du calcul de base. Nous relevons donc l'exposition et les équipements avant de confirmer ce format plutôt que la Thermopompe PTAC DURASTAR | 12000 BTU - R32.
Chambly en octobre : mettre les chambres en ordre avant le froid
La grille, la neige et le dégagement extérieur
La grille extérieure se pose au-dessus de la ligne de neige ; sur un bâtiment de plain-pied, le repère est le banc que laisse le déneigement des allées. Le manchon mural garde sa pente vers l'extérieur et son pourtour calfeutré serré : c'est ce joint qui décide du confort de novembre.
Le circuit et la prise de chaque chambre
Chaque appareil demande 220 V sur un circuit dédié, avec la prise à portée du cordon. Dans une résidence où les chambres se suivent sur un même panneau, le calcul de charge se fait sur l'aile complète avant de chiffrer, et une mise à niveau du panneau figure au devis avant la signature.
La saison froide, jour après jour
- Un délai de trois minutes au redémarrage protège le compresseur.
- De la vapeur blanche à la grille en mode chauffage signale un dégivrage, qui se termine seul.
- Un sifflement bref accompagne le changement de cycle.
Une odeur de brûlé, un disjoncteur qui saute, un code d'erreur récurrent ou de l'eau côté chambre commandent l'arrêt et un appel au service. Le filtre se nettoie aux deux semaines et un entretien CVAC annuel reprend serpentins, écoulement et raccords ; notre service de nettoyage traite l'aile en une visite.
AirGreen, pour une résidence occupée à l'année
Entreprise familiale de Montréal depuis plus de quinze ans, AirGreen dessert Montréal, Laval, Longueuil, la Rive-Nord et la Rive-Sud, avec une assurance responsabilité de 5 000 000 $. Nos options de financement permettent d'équiper une aile avant l'hiver plutôt qu'au fil des plaintes.
Planifiez votre estimation gratuite pour la Thermopompe PTAC DURASTAR | 9 000 BTU - R32. Nous relevons l'exposition et les équipements de chaque chambre, vérifions la charge du panneau d'aile et vous remettons une soumission écrite.
Garantie : 10 ans sur le compresseur, 10 ans sur les pièces et 6 ans sur la main-d’œuvre, directement du distributeur.
