AirGreen lexiconWall-mounted heat pumps

Wall heat pumps and refrigerant: three 12,000 BTU/h models, from factory to recovery

17 min
Comparison · Wall heat pumps · Refrigerant

What circulates inside the unit, and what the law provides for it

A 12,000 BTU/h wall heat pump arrives with a little under one kilogram of refrigerant in its outdoor unit. More is added when the line set is long, and it is recovered before any repair of the circuit and when the unit is removed. Here are three models sold by AirGreen, from the brands named in the earlier version of this article, in alphabetical order: the charge each manufacturer publishes, what Québec's Regulation respecting halocarbons provides at each stage, then the same certified figures as in our other comparisons.

3 models · 12,000 BTU/hFactory charge and maximum chargeA2L refrigerants: R-32 and R-454BAlphabetical order, no ranking
BOSCH Climate 5000 Regular R-454B 12,000 BTU (AirGreen image)
BOSCH

Climate 5000 Regular R-454B

Factory charge: 0.92 kg of R-454B

BMS500-AAU012-1AHWXD / BMS500-AAS012-1CSXRD · AHRI 215223298

See the product page
FUJITSU AIRSTAGE ALTAIR 700 (KMAS) 12,000 BTU (AirGreen image)
FUJITSU AIRSTAGE

ALTAIR 700 (KMAS)

Factory charge: 0.85 kg of R-32

ASUH12KMAS / AOUH12KMAS1 · AHRI 214390708

See the product page
GREE VIREO R32 12,000 BTU (AirGreen image)
GREE

VIREO R32

Factory charge: 0.80 kg of R-32

VIR12HP230V1R32AH / VIR12HP230V1R32AO · AHRI 214813257

Also sold under other names: GREE CLIVIA, GREE CROSSOVER, GREE ENVO, KINGHOME CLIVIA, TOSOT CLIVIA and TOSOT PULAR (NEEP series “Clivia” and “Pular”: same certified values at −15 and −30 °C, small differences at 8.3 and −8.3 °C)

See the product page

This article was rebuilt on November 17, 2026. It presented “truly committed brands” for a “greener Québec”, with no published figures to support it. It now sets side by side what is published and can be checked, for models AirGreen sells in the brands it named: BOSCH, FUJITSU AIRSTAGE and GREE.

Estimated operating cost

What the electricity costs, in dollars, winter and summer

The refrigerant does not show on the bill; the certified efficiency does. Here is AirGreen's estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included, with the method used on all our comparison pages. Electric baseboards serve as the reference. The cards detail BOSCH and FUJITSU AIRSTAGE, first in alphabetical order; the table below gives all three with the same settings.

All three, with the same settings

How this amount is calculated
  1. Heat to supply over the winter. A zone with a heat loss of 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down when the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one used by Hydro-Québec's calculators. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The refrigerant, from factory to removal

Four stages, one quantity to follow

In Québec, a heat pump is a “refrigeration or air-conditioning appliance” under the Regulation respecting halocarbons, and R-32 is listed in its schedule. R-454B is a blend that contains R-32, and the regulation applies to halocarbons used alone or in a mixture. Choose a stage: on the left, what the regulation provides; on the right, what each sheet publishes for that stage.

What the sheets say, and what we keep

  • The FUJITSU AIRSTAGE brochure calls R-32 an “environmentally friendly” refrigerant and announces a GWP reduction compared with R-410A. The page keeps only the GWP values and their source: 675 for R-32, 466 for R-454B, 2,088 for R-410A (IPCC, AR4).
  • The BOSCH and GREE sheets give the charge in ounces; FUJITSU AIRSTAGE in pounds, ounces and grams. The page converts to kilograms (1 oz = 28.35 g).
  • The charge at the maximum length is an AirGreen calculation: factory charge, plus the published amount per foot for each foot beyond the pre-charged length. None of the three sheets publishes this total.
  • GWP says nothing about the unit's electricity use; that is in the “Cost per season” section.

Sources: Regulation respecting halocarbons (chapter Q-2, r. 29), s. 1, 3, 10, 14, 43 and 44, LégisQuébec (French text); BOSCH, sheet BTC 769208307 C (01.2026); FUJITSU AIRSTAGE, brochure FG8150D (rev. 4/2025) and submittal 12KMAS1 (version 20250409A); GREE, submittal GREE_VIR12HP_230V_R32_AH_AO_SUB_07302025.

Overview

All three, efficiency and refrigerant on one line

Alphabetical order to start. Sort by efficiency, cold or refrigerant charge: sorting arranges, it does not rank.

SEER2, HSPF2, −15 °C and coldest point: AHRI certificates read through NEEP. Advertised range and charge: each manufacturer's document. The coldest point is not measured at the same temperature for all: read each capacity with its temperature.

Extreme cold

The same refrigerant in extreme cold: what each sheet publishes below −15 °C

The same refrigerant does all the work, down to the bottom of the advertised range. At −15 °C, all three are certified at the same temperature. Colder, NEEP publishes a last point at −25 °C for BOSCH and at −30 °C for GREE; FUJITSU AIRSTAGE advertises its heating range down to −15 °C. BOSCH also publishes its own table at −15, −20 and −25 °C. Between two published values, the page shows the range, with no made-up figure in between.

A filled shape: NEEP-certified value. A hollow shape: manufacturer's value, not certified. When both exist at the same temperature, the certificate prevails in comparisons.

Features

What each document names, beyond the refrigerant

Wi-Fi, wall control, heated base pan, coil protection: what each sheet says. A dotted pill marks a silent document, not a missing feature.

Quiet

What the three sheets say about sound

Five speeds with figures for BOSCH, four for FUJITSU AIRSTAGE, a minimum and a maximum for GREE. Each sheet publishes it its own way.

dB

How to read these figures. The A-weighted decibel follows the ear's sensitivity; the lower the figure, the quieter the unit. Each dot is a published fan speed.

Why this is not a ranking. None of the three sheets states the distance or the test room. Only the GREE sheet writes “sound pressure level”; BOSCH writes “noise level” and FUJITSU AIRSTAGE “niveaux sonores” (sound levels). Figures taken in different ways do not compare directly.

Each manufacturer measures its own way: these figures place a unit within its own range, they do not decide between the three.
Installation

Line-set length: what it changes on the wall and in refrigerant

The longer the line set, the more refrigerant must be added, and the more there will be to recover one day. Two checks come first: the free width of the planned wall, and the distance to the outdoor unit compared with what each manufacturer allows.

Is your wall wide enough?

38 in

Scale diagram of each indoor unit's published width. Each installation manual also requires clearances on the sides and to the ceiling: check them before drilling.

Piping length

25 ft

Pre-charged and maximum lengths published by each manufacturer. Beyond the pre-charged length, the installer adds refrigerant according to the manual.

Spec sheets

Three sheets, from the refrigerant to the weight of each unit

The three sheets have the same rows in the same order, including the refrigerant charge. Choose a model.

MeasureBOSCH Climate 5000 Regular R-454BSource
Certificate and directories
AHRI certificate · NEEP recordAHRI 215223298 · NEEP 392006NEEP directory, viewed November 17, 2026
Company registered on the certificateBosch Thermotechnology Corp“manufacturer” field of the NEEP record
ENERGY STAR and ENERGY STAR cold climateYes; cold climate: yesNEEP 392006 (ENERGY STAR fields)
Refrigerant, from factory to recovery
Refrigerant and safety classR-454B · A2L classNEEP; class: ASHRAE 34
100-year GWP466IPCC, Fourth Assessment Report (AR4)
Factory charge32.45 oz (0.92 kg)sheet BTC 769208307 C: 32.45 oz (0.92 kg), 24.6 ft pre-charged, 0.16 oz/ft, 82 ft maximum
Pre-charged length and amount added per foot24.6 ft; 0.16 oz/ft beyondsheet BTC 769208307 C: 32.45 oz (0.92 kg), 24.6 ft pre-charged, 0.16 oz/ft, 82 ft maximum
Total charge at the maximum length41.63 oz (1.18 kg) at 82 ftAirGreen calculation: factory charge + (maximum length − pre-charged length) × amount per foot
Seasonal ratings, same test conditions
SEER225.5NEEP 392006
EER213NEEP 392006
HSPF2 Region IV / V10.6 / 8.0NEEP 392006
Certified heating
8.3 °C: min. / rated / max. capacity4,500 / 12,000 / 15,400 BTU/hNEEP 392006, 47 °F
−8.3 °C: min. / rated / max. capacity4,500 / 10,100 / 10,100 BTU/hNEEP 392006, 17 °F
−15 °C: min. / rated / max. capacity3,600 / 8,400 / 8,400 BTU/hNEEP 392006, 5 °F
COP at −15 °C, min. / rated / max.1.99 / 2.30 / 2.30NEEP 392006, 5 °F
Coldest point published by NEEP
Test temperature−25 °C (−13 °F)NEEP 392006
Min. / max. capacity at the coldest point900 / 5,300 BTU/hNEEP 392006
COP at the coldest point, min. / max.0.73 / 1.60NEEP 392006
Certified cooling
Min. / rated / max. capacity at 35 °C2,900 / 12,000 / 14,500 BTU/hNEEP 392006, 95 °F
Published sound
Indoor fan: sound per speed5 speeds: Turbo 46 · High 38 · Medium 33 · Low 18 · Silent 18 dB(A)BOSCH, submittal sheet BTC 769208307 C (01.2026)
Outdoor-unit fan: published soundMaximum: 56 dB(A)BOSCH, submittal sheet BTC 769208307 C (01.2026)
Installation and electrical
Advertised heating / cooling range−25 to 24 °C / −25 to 50 °CBOSCH, submittal sheet BTC 769208307 C (01.2026)
Heated base panYes, 150 WNEEP 392006 (pan heater field)
Maximum piping length82 ftBOSCH, submittal sheet BTC 769208307 C (01.2026)
Pre-charged length24.6 ft (32.45 oz charge), add 0.16 oz/ftBOSCH, submittal sheet BTC 769208307 C (01.2026)
Maximum height difference49.2 ftBOSCH, submittal sheet BTC 769208307 C (01.2026)
Liquid – gas diameters1/4 – 3/8 inBOSCH, submittal sheet BTC 769208307 C (01.2026)
Indoor unit W × H × D, weight31.42 × 11.85 × 9.21 in, 22.93 lb (10.4 kg)BOSCH, submittal sheet BTC 769208307 C (01.2026)
Outdoor unit W × H × D, weight30.12 × 21.85 × 11.93 in, 62.17 lb (28.2 kg)BOSCH, submittal sheet BTC 769208307 C (01.2026)
Electrical protectionMCA 12 A (outdoor), max. fuse 15 ABOSCH, submittal sheet BTC 769208307 C (01.2026)
Dehumidification2.32 pints/h (about 1.1 L/h)BOSCH, submittal sheet BTC 769208307 C (01.2026)
Questions

What people ask us about refrigerant

Is a wall heat pump covered by the Regulation respecting halocarbons?

Yes. The regulation defines a “refrigeration or air-conditioning appliance” and includes the heat pump in it (s. 3). R-32 is listed in Schedule I, and the regulation applies to halocarbons used alone or in a mixture (s. 1), which also covers R-454B, a blend that contains R-32.

Who may install the unit or add refrigerant?

Only a person holding the environmental qualification attestation provided for in section 44, issued notably by the Commission de la construction du Québec, may install, maintain, repair or dismantle the unit, or charge, transfer or drain its refrigerant (s. 43).

What happens to the refrigerant when the unit is replaced?

Before components that contain it are dismantled, it must be recovered with the appropriate equipment, into a container designed for that purpose (s. 10). Anyone who holds a unit in order to recover or dispose of it must recover the refrigerant, or have it recovered, as soon as possible (s. 14).

R-32 or R-454B: which one to choose?

The page does not decide. Both are classified A2L by the ASHRAE 34 standard. Their 100-year GWP differs (675 and 466, IPCC AR4), and the published charge also differs from one model to the next; comfort and the bill depend on the certified efficiency and the installation.

Why does the page not use the words “eco-friendly” or “green”?

Because they cannot be measured. The page sticks to what is published and can be checked: the type of refrigerant, its GWP, the quantity charged, the certified efficiency and what the law provides.

Does the GREE VIREO R32 exist under other names?

It belongs to a platform of seven 12,000 BTU R-32 wall units: GREE CLIVIA, GREE CROSSOVER, GREE ENVO, GREE VIREO, KINGHOME CLIVIA, TOSOT CLIVIA and TOSOT PULAR. Their certified values are the same at −15 and −30 °C; the differences are at 8.3 °C and −8.3 °C. For example, at 8.3 °C, the maximum capacity is 14,600 BTU/h for the VIREO and 15,690 for the ENVO. The “Clivia platform” page shows them value by value; it does not say they are the same unit.

Do these models qualify for a rebate?

It depends on the program's official list on the day of the application and on your situation. Check the current Hydro-Québec (LogisVert) or Rénoclimat list before signing.

All three are offered by AirGreen.

Tell us the planned distance between the room and the outdoor unit, and whether it replaces an existing unit: the quote takes it into account.

Sources and documents

Where each number comes from

NEEP, record 392006 (BOSCH Climate 5000 Regular R-454B 12,000 BTU)AHRI 215223298 · viewed November 17, 2026 NEEP, record 397907 (FUJITSU AIRSTAGE ALTAIR 700, 12KMAS1)AHRI 214390708 · viewed November 17, 2026 NEEP, record 392684 (GREE VIREO R32 12,000 BTU)AHRI 214813257 · NEEP series “Clivia” · viewed November 17, 2026 NEEP, record 393215 (GREE ENVO R32 12,000 BTU)Same “Clivia” series · compared with the VIREO R32 · viewed November 17, 2026 BOSCH, 12K Regular wall submittal sheetBTC 769208307 C, 01.2026 · charge, piping, sound, heating table · viewed November 17, 2026 FUJITSU AIRSTAGE, ALTAIR 700 brochure (KMAS, French)FG8150D, rev. 4/2025 · piping, sound, ranges, accessories · viewed November 17, 2026
FUJITSU AIRSTAGE, submittal 12KMAS1Version 20250409A, copy hosted by a distributor · R32 charge of 1 lb 14 oz (850 g), 0.22 oz/ft added · read November 17, 2026
GREE, VIREO R32 12,000 submittalGREE_VIR12HP_230V_R32_AH_AO_SUB_07302025 · charge, piping, sound, features · viewed November 17, 2026 Regulation respecting halocarbons (chapter Q-2, r. 29)LégisQuébec, up to date as of July 1, 2026 · s. 1, 3, 10, 14, 43, 44 and Schedule I · viewed November 17, 2026 Commission de la construction du Québec, “Qualification environnementale : halocarbures”Attestation and recognized training · viewed November 17, 2026 Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design · viewed November 17, 2026
IPCC, Fourth Assessment Report (AR4) and ASHRAE 34 standard100-year GWP: R-32 675, R-454B 466, R-410A 2,088 · A2L safety class