AirGreenYORK
YORK · R Series ceiling cassette YORK at AirGreenSold and installed by AirGreen in Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full YORK range
AirGreen × YORKSold and installed by AirGreen4-way cassetteUp to 20 SEERBuilt-in condensate pump18,000 to 48,000 BTU/hMontreal · Laval · Longueuil · South Shore · North Shore
01 · Model by model

Six cassettes, 18,000 to 48,000 BTU/h, complete system.

Select a size: the indoor unit, the R Series outdoor unit that goes with it, and what the installation needs.

Size
DHR24NKB21S + DHR24CSB21S4-way cassette · 24,000 BTU/h · AHRI 8578437
See the product page →
Rated cooling
23,800 BTU/hrange 8,200 to 29,000
Heating at 8.3 °C
27,200 BTU/hrange 8,200 to 32,400
SEER · EER · HSPF
20 · 10.65 · 10
Heats
down to −18 °C
Indoor unit
37.5 × 9.5 × 31 in.60 lb · max. airflow 767 CFM
Panel
PNLR0437.5 × 2.5 × 37.5 in.
Indoor sound
47 → 38 dB(A)highest → lowest speed
Outdoor unit
39 × 31 × 17 in.152 lb · 57 dB(A)
Circuits (separate)
24 A · 40 Aoutdoor MCA · MOCP; indoor MCA 1 A
Liquid · vapour lines
3/8 · 5/8 in.1 in. drain
Max. length · lift
164 ft · 49.2 ft
Factory charge
77.6 oz

System SEER, EER and HSPF ratings under AHRI 210/240, heating rated at 8.3 °C (47 °F), as printed by YORK. Dimensions in inches: width × height × depth; net weights. The min. to max. ranges are those of the R Series outdoor unit in the 2020 catalogue. YORK requires separate power for the indoor and outdoor units.

02 · Three forms, one outdoor unit

The cassette versus the ducted and floor-ceiling units.

On the same R Series outdoor unit, the indoor form changes efficiency, airflow and sound. Size for size:

Size
The three R Series forms at 24,000 BTU/h
Item4-way cassetteDuctedFloor-ceiling
SEER201616
EER10.6510.6510.65
HSPF101010
Rated heating at 8.3 °C27,200 BTU/h27,200 BTU/h27,200 BTU/h
Max. airflow767 CFM826 CFM708 CFM
Indoor sound at lowest38 dB(A)40 dB(A)40 dB(A)
Indoor unit weight60 lb75 lb88 lb

In green, the best value in the row. Same outdoor unit for all three forms. See also: Ducted · Floor-ceiling.

AirGreen × YORK

YORK designs the cassette; AirGreen fits it into your ceiling.

AirGreen picks the size with you, checks the space above the ceiling and the drain route, then installs the cassette and the outdoor unit.

YORK

What YORK brings

  • 4-way dischargeWith a swing louver and a cleanable filter, according to YORK.
  • Built-in condensate pumpThe cassette lifts its own water.
  • 26.5 to 44 in. panelThe only visible part, by size.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free visitWe measure the installation space, the electrical service, and the route for the refrigerant lines and the drain.
  • Clear quoteThe exact model, what is included and the price, in writing.
  • RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.

The result: a cassette installed in the ceiling by AirGreen, with only a discreet panel showing.

The YORK shop · Cassettes

All 6 YORK cassettes, right below.

One listing per size, with the indoor unit, the outdoor unit and the AHRI number.

YORK
03 · In the ceiling

What shows in the ceiling: a square panel, three sizes.

Everything else is hidden. The panel is ordered with the cassette, by size.

PNLR0326.5 in. squarefor 18,000 BTU/hPNLR0437.5 in. squarefor 24,000 · 30,000 · 36,000 BTU/hPNLR0544 in. squarefor 48,000 BTU/h
  • The cassette body sits above the ceiling: from 26.5 × 9.5 × 23.5 in. (18,000 BTU/h) to 40 × 11.5 × 35.8 in. (48,000 BTU/h), as printed by YORK; the 42,000 BTU/h is the tallest, at 39 × 12.5 × 38 in.
  • For the 42,000 BTU/h, the catalogue names the PNLR04 but prints a 41 in. size: we confirm the panel when ordering.
  • The ceiling cut-out is not published in the YORK documents we read: we confirm it on site.
04 · Features

What YORK builds into the cassette.

Built-in condensate pump

“Internal condensate drain pump”: the cassette lifts its own condensate water to a 1 in. drain.

4-way discharge

Air leaves from all four sides of the panel, with a swing louver, to spread it through the room.

Cleanable filter

“Cleanable air filter”, according to YORK.

DRCR remote

Supplied with the cassette. DWCR or DWCR2 wired wall control as an option.

05 · Before you choose

What to know about the cassette before you sign.

−18 °Climit of the R Series heating range (0 °F), higher than that of the P and X wall units (−20 °C).
14 daysa year, at least, when the low drops below that limit at Montréal–Trudeau (14.26 days below −20 °C, 1981-2010 normals).
2electrical circuits: YORK requires separate power for the indoor unit and the outdoor unit.
0/6AHRI numbers of our cassettes on the October 26, 2026 LogisVert list or at ENERGY STAR.
  • Below −18 °C, the unit is outside its published heating range: we plan backup heat from the quote.
Frequently asked questions

What people ask us about the YORK cassette.

Which YORK cassette is the most efficient?

The 24,000 and 30,000 BTU/h ones: 20 SEER, the only R Series units at that rating. The four other sizes are rated 16.

What kind of ceiling does it need?

A ceiling with enough space above it to hold the cassette body; only the square panel, 26.5 to 44 in. depending on size, stays visible. We confirm the space and access at the visit.

Where does the condensate water go?

A built-in pump lifts it to a 1 in. drain; we plan the drain route at the visit.

How cold does the cassette heat?

Down to −18 °C (0 °F), per the range YORK publishes for the R Series. In Montreal it gets colder on at least 14 days a year: we plan backup heat.

Does the R Series cassette qualify for LogisVert?

No: none of the 6 AHRI numbers on our listings is on Hydro-Québec’s October 26, 2026 list. So we promise no amount.

Sources and dates checked

  1. YORK, Mini-Split Systems catalogue PUBL-7782v6 (November 2020): R Series, outdoor unit (p. 17), cassette (p. 18), ducted (p. 19), floor-ceiling (p. 20), controls (pp. 40 to 43); copy in our documents, re-read October 26, 2026.
  2. Hydro-Québec, LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.
  3. ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
  4. Environment and Climate Change Canada, 1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026.
  5. airgreen.ca product pages: model and AHRI numbers of the systems we carry, read October 26, 2026.

Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.