Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
YORK R Series ceiling cassette: 4-way discharge, up to 20 SEER, recessed in the ceiling
The 4-way cassette is recessed into the ceiling: only a square panel shows. At 24,000 and 30,000 BTU/h it is rated 20 SEER, the only R Series form at that level. Six sizes, from 18,000 to 48,000 BTU/h, with a built-in condensate pump.
The only R Series form that reaches 20 SEER, at 24,000 and 30,000 BTU/h.
YORK 2020 catalogue, p. 18; AHRI 210/240 ratings.
Six cassettes, 18,000 to 48,000 BTU/h, complete system.
Select a size: the indoor unit, the R Series outdoor unit that goes with it, and what the installation needs.
- Rated cooling
- 17,000 BTU/hrange 5,400 to 18,700
- Heating at 8.3 °C
- 18,400 BTU/hrange 4,700 to 22,200
- SEER · EER · HSPF
- 16 · 10.05 · 9
- Heats
- down to −18 °C
- Indoor unit
- 26.5 × 9.5 × 23.5 in.44 lb · max. airflow 588 CFM
- Panel
- PNLR0326.5 × 2 × 26.5 in.
- Indoor sound
- 47 → 37 dB(A)highest → lowest speed
- Outdoor unit
- 38 × 28 × 16 in.106 lb · 56 dB(A)
- Circuits (separate)
- 17 A · 25 Aoutdoor MCA · MOCP; indoor MCA 1 A
- Liquid · vapour lines
- 1/4 · 1/2 in.1 in. drain
- Max. length · lift
- 164 ft · 49.2 ft
- Factory charge
- 49.38 oz
- Rated cooling
- 23,800 BTU/hrange 8,200 to 29,000
- Heating at 8.3 °C
- 27,200 BTU/hrange 8,200 to 32,400
- SEER · EER · HSPF
- 20 · 10.65 · 10
- Heats
- down to −18 °C
- Indoor unit
- 37.5 × 9.5 × 31 in.60 lb · max. airflow 767 CFM
- Panel
- PNLR0437.5 × 2.5 × 37.5 in.
- Indoor sound
- 47 → 38 dB(A)highest → lowest speed
- Outdoor unit
- 39 × 31 × 17 in.152 lb · 57 dB(A)
- Circuits (separate)
- 24 A · 40 Aoutdoor MCA · MOCP; indoor MCA 1 A
- Liquid · vapour lines
- 3/8 · 5/8 in.1 in. drain
- Max. length · lift
- 164 ft · 49.2 ft
- Factory charge
- 77.6 oz
- Rated cooling
- 28,200 BTU/hrange 8,800 to 31,400
- Heating at 8.3 °C
- 31,200 BTU/hrange 8,200 to 33,600
- SEER · EER · HSPF
- 20 · 10 · 9
- Heats
- down to −18 °C
- Indoor unit
- 37.5 × 9.5 × 31 in.71 lb · max. airflow 885 CFM
- Panel
- PNLR0437.5 × 2.5 × 37.5 in.
- Indoor sound
- 49 → 40 dB(A)highest → lowest speed
- Outdoor unit
- 39 × 31 × 17 in.159 lb · 58 dB(A)
- Circuits (separate)
- 24 A · 40 Aoutdoor MCA · MOCP; indoor MCA 1.5 A
- Liquid · vapour lines
- 3/8 · 5/8 in.1 in. drain
- Max. length · lift
- 164 ft · 49.2 ft
- Factory charge
- 84.65 oz
- Rated cooling
- 34,000 BTU/hrange 10,800 to 39,000
- Heating at 8.3 °C
- 41,000 BTU/hrange 9,800 to 49,500
- SEER · EER · HSPF
- 16 · 10.4 · 9
- Heats
- down to −18 °C
- Indoor unit
- 37.5 × 9.5 × 31 in.71 lb · max. airflow 1,097 CFM
- Panel
- PNLR0437.5 × 2.5 × 37.5 in.
- Indoor sound
- 51 → 43 dB(A)highest → lowest speed
- Outdoor unit
- 43.5 × 43 × 17 in.205 lb · 63 dB(A)
- Circuits (separate)
- 29 A · 45 Aoutdoor MCA · MOCP; indoor MCA 1.5 A
- Liquid · vapour lines
- 3/8 · 5/8 in.1 in. drain
- Max. length · lift
- 164 ft · 49.2 ft
- Factory charge
- 123.45 oz
- Rated cooling
- 39,500 BTU/hrange 11,000 to 41,000
- Heating at 8.3 °C
- 44,000 BTU/hrange 12,000 to 51,000
- SEER · EER · HSPF
- 16 · 8.95 · 9
- Heats
- down to −18 °C
- Indoor unit
- 39 × 12.5 × 38 in.71 lb · max. airflow 1,097 CFM
- Panel
- PNLR04size confirmed in the quote
- Indoor sound
- 51 → 43 dB(A)highest → lowest speed
- Outdoor unit
- 37.7 × 53 × 16 in.210 lb · 61 dB(A)
- Circuits (separate)
- 31 A · 50 Aoutdoor MCA · MOCP; indoor MCA 1.5 A
- Liquid · vapour lines
- 3/8 · 5/8 in.1 in. drain
- Max. length · lift
- 164 ft · 49.2 ft
- Factory charge
- 130.51 oz
- Rated cooling
- 48,000 BTU/hrange 20,400 to 50,500
- Heating at 8.3 °C
- 54,500 BTU/hrange 17,500 to 61,500
- SEER · EER · HSPF
- 16 · 8.2 · 9
- Heats
- down to −18 °C
- Indoor unit
- 40 × 11.5 × 35.8 in.95 lb · max. airflow 1,357 CFM
- Panel
- PNLR0544 × 3 × 44 in.
- Indoor sound
- 53 → 41 dB(A)highest → lowest speed
- Outdoor unit
- 38 × 53 × 16 in.232 lb · 59 dB(A)
- Circuits (separate)
- 45 A · 70 Aoutdoor MCA · MOCP; indoor MCA 2 A
- Liquid · vapour lines
- 3/8 · 5/8 in.1 in. drain
- Max. length · lift
- 229 ft · 49.2 ft
- Factory charge
- 141.09 oz
System SEER, EER and HSPF ratings under AHRI 210/240, heating rated at 8.3 °C (47 °F), as printed by YORK. Dimensions in inches: width × height × depth; net weights. The min. to max. ranges are those of the R Series outdoor unit in the 2020 catalogue. YORK requires separate power for the indoor and outdoor units.
The cassette versus the ducted and floor-ceiling units.
On the same R Series outdoor unit, the indoor form changes efficiency, airflow and sound. Size for size:
| Item | 4-way cassette | Ducted | |
|---|---|---|---|
| SEER | 16 | 16 | 16 |
| EER | 10.05 | 11 | 11 |
| HSPF | 9 | 9.5 | 9.5 |
| Rated heating at 8.3 °C | 18,400 BTU/h | 18,800 BTU/h | 19,100 BTU/h |
| Max. airflow | 588 CFM | 588 CFM | 588 CFM |
| Indoor sound at lowest | 37 dB(A) | 28 dB(A) | 32 dB(A) |
| Indoor unit weight | 44 lb | 73 lb | 86 lb |
| Item | 4-way cassette | Ducted | |
|---|---|---|---|
| SEER | 20 | 16 | 16 |
| EER | 10.65 | 10.65 | 10.65 |
| HSPF | 10 | 10 | 10 |
| Rated heating at 8.3 °C | 27,200 BTU/h | 27,200 BTU/h | 27,200 BTU/h |
| Max. airflow | 767 CFM | 826 CFM | 708 CFM |
| Indoor sound at lowest | 38 dB(A) | 40 dB(A) | 40 dB(A) |
| Indoor unit weight | 60 lb | 75 lb | 88 lb |
| Item | 4-way cassette | Ducted | |
|---|---|---|---|
| SEER | 20 | 16 | 17 |
| EER | 10 | 8.55 | 9.85 |
| HSPF | 9 | 9 | 9 |
| Rated heating at 8.3 °C | 31,200 BTU/h | 31,200 BTU/h | 31,200 BTU/h |
| Max. airflow | 885 CFM | 826 CFM | 885 CFM |
| Indoor sound at lowest | 40 dB(A) | 40 dB(A) | 38 dB(A) |
| Indoor unit weight | 71 lb | 75 lb | 106 lb |
| Item | 4-way cassette | Ducted | |
|---|---|---|---|
| SEER | 16 | 16 | 16 |
| EER | 10.4 | 10.35 | 10.35 |
| HSPF | 9 | 9 | 9 |
| Rated heating at 8.3 °C | 41,000 BTU/h | 41,000 BTU/h | 41,000 BTU/h |
| Max. airflow | 1,097 CFM | 1,180 CFM | 1,121 CFM |
| Indoor sound at lowest | 43 dB(A) | 45 dB(A) | 46 dB(A) |
| Indoor unit weight | 71 lb | 101 lb | 106 lb |
| Item | 4-way cassette | Ducted | |
|---|---|---|---|
| SEER | 16 | 16 | 16 |
| EER | 8.95 | 9.5 | 9.4 |
| HSPF | 9 | 9 | 9 |
| Rated heating at 8.3 °C | 44,000 BTU/h | 44,000 BTU/h | 44,000 BTU/h |
| Max. airflow | 1,097 CFM | 1,180 CFM | 1,121 CFM |
| Indoor sound at lowest | 43 dB(A) | 44 dB(A) | 47 dB(A) |
| Indoor unit weight | 71 lb | 101 lb | 110 lb |
| Item | 4-way cassette | Ducted | |
|---|---|---|---|
| SEER | 16 | 16 | 16 |
| EER | 8.2 | 9.05 | 8.3 |
| HSPF | 9 | 9 | 9 |
| Rated heating at 8.3 °C | 54,500 BTU/h | 54,500 BTU/h | 54,500 BTU/h |
| Max. airflow | 1,357 CFM | 1,475 CFM | 1,121 CFM |
| Indoor sound at lowest | 41 dB(A) | 41 dB(A) | 43 dB(A) |
| Indoor unit weight | 95 lb | 124 lb | 130 lb |
In green, the best value in the row. Same outdoor unit for all three forms. See also: Ducted ·
YORK designs the cassette; AirGreen fits it into your ceiling.
AirGreen picks the size with you, checks the space above the ceiling and the drain route, then installs the cassette and the outdoor unit.
What YORK brings
- 4-way dischargeWith a swing louver and a cleanable filter, according to YORK.
- Built-in condensate pumpThe cassette lifts its own water.
- 26.5 to 44 in. panelThe only visible part, by size.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the installation space, the electrical service, and the route for the refrigerant lines and the drain.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: a cassette installed in the ceiling by AirGreen, with only a discreet panel showing.
All 6 YORK cassettes, right below.
One listing per size, with the indoor unit, the outdoor unit and the AHRI number.
What shows in the ceiling: a square panel, three sizes.
Everything else is hidden. The panel is ordered with the cassette, by size.
- The cassette body sits above the ceiling: from 26.5 × 9.5 × 23.5 in. (18,000 BTU/h) to 40 × 11.5 × 35.8 in. (48,000 BTU/h), as printed by YORK; the 42,000 BTU/h is the tallest, at 39 × 12.5 × 38 in.
- For the 42,000 BTU/h, the catalogue names the PNLR04 but prints a 41 in. size: we confirm the panel when ordering.
- The ceiling cut-out is not published in the YORK documents we read: we confirm it on site.
What YORK builds into the cassette.
“Internal condensate drain pump”: the cassette lifts its own condensate water to a 1 in. drain.
Air leaves from all four sides of the panel, with a swing louver, to spread it through the room.
“Cleanable air filter”, according to YORK.
Supplied with the cassette. DWCR or DWCR2 wired wall control as an option.
What to know about the cassette before you sign.
- Below −18 °C, the unit is outside its published heating range: we plan backup heat from the quote.
What people ask us about the YORK cassette.
Which YORK cassette is the most efficient?
The 24,000 and 30,000 BTU/h ones: 20 SEER, the only R Series units at that rating. The four other sizes are rated 16.
What kind of ceiling does it need?
A ceiling with enough space above it to hold the cassette body; only the square panel, 26.5 to 44 in. depending on size, stays visible. We confirm the space and access at the visit.
Where does the condensate water go?
A built-in pump lifts it to a 1 in. drain; we plan the drain route at the visit.
How cold does the cassette heat?
Down to −18 °C (0 °F), per the range YORK publishes for the R Series. In Montreal it gets colder on at least 14 days a year: we plan backup heat.
Does the R Series cassette qualify for LogisVert?
No: none of the 6 AHRI numbers on our listings is on
Your YORK cassette, in the ceiling, installed by AirGreen.
At the free visit, we check the space above the ceiling, the drain route and the two electrical circuits, and choose the size.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): R Series, outdoor unit (p. 17), cassette (p. 18), ducted (p. 19),floor-ceiling (p. 20), controls (pp. 40 to 43); copy in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
- Environment and Climate Change Canada,
1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026. - airgreen.ca product pages: model and AHRI numbers of the systems we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.