YORK wall-mounted heat pumps: P, X or Z Series, depending on the room and the coldest night
The P and X Series heat down to −20 °C; the Z Series, down to −30 °C. Across the three: 16 to 28 SEER, six sizes from 9,000 to 36,000 BTU/h and four models on 115 V. Compare them size for size, then choose by room.
How cold each series heats, per the range YORK publishes.
Heating ranges: YORK 2020 catalogue. Climate: ECCC, station 7025250.
P, X and Z: three YORK wall units, each for a different kind of room.
YORK names them after their top rating: “P SERIES 18 SEER”, “X SERIES 23 SEER”, “Z SERIES 28 SEER”. Ratings then vary by size.
The most sizes: the only YORK wall unit in our catalogue at 30,000 and 36,000 BTU/h.
Sizes9,000 to 36,000 BTU/hSEER16 to 18Heatsdown to −20 °C115 V9,000 and 12,000Efficiency on 115 V: 22 to 23 SEER, versus 16 for the P.
Sizes9,000 to 24,000 BTU/hSEER20 to 23Heatsdown to −20 °C115 V9,000 and 12,000Deep cold: heats down to −30 °C, built-in
P, X and Z at the same size, row by row.
Same nominal size, same voltage: what changes from one series to the next, from efficiency to the outdoor unit’s weight.
| Item | P Series | X Series | Z Series |
|---|---|---|---|
| Models | DHP09NWB21SDHP09CSB21S | DHX09NWB21SDHX09CSB21S | DHZ09NWB21SDHZ09CSB21S |
| SEER · EER · HSPF | 16 · 10 · 9 | 23 · 14.29 · 10.5 | 28 · 15 · 10.5 |
| Rated heating at 8.3 °C | 9,500 BTU/hmax. 12,000 | 11,000 BTU/hmax. 12,000 | 9,000 BTU/hmax. 13,645 |
| Rated cooling | 9,000 BTU/h | 9,000 BTU/h | 9,000 BTU/h |
| Heats down to | −20 °C | −20 °C | −30 °C |
| Indoor sound, lowest speed | 28 dB(A) | 29 dB(A) | 22 dB(A) |
| Outdoor sound | 52 dB(A) | 53 dB(A) | 53 dB(A) |
| Outdoor unit (W × H × D) | 30.5 × 21 × 12.5 in.65 lb | 33 × 21 × 13 in.78 lb | 35 × 24 × 15 in.99 lb |
| MCA · MOCP | 9 A · 15 A | 9 A · 15 A | 12 A · 15 A |
| Refrigerant vapour line (liquid 1/4 in.) | 3/8 in. | 3/8 in. | 1/2 in. |
| Max. line length | 49.2 ft | 49.2 ft | 49.2 ft |
| CS532AH adapter | CS532AH adapter | Built in | |
| Remote | DRCPX | DRCPX | DRCZ |
| Item | P Series | X Series | Z Series |
|---|---|---|---|
| Models | DHP12NWB21SDHP12CSB21S | DHX12NWB21SDHX12CSB21S | DHZ12NWB21SDHZ12CSB21S |
| SEER · EER · HSPF | 16 · 9.25 · 9 | 22 · 12.5 · 10.1 | 23 · 12.7 · 10.5 |
| Rated heating at 8.3 °C | 13,000 BTU/hmax. 14,000 | 13,000 BTU/hmax. 14,000 | 13,000 BTU/hmax. 18,766 |
| Rated cooling | 12,000 BTU/h | 12,000 BTU/h | 12,000 BTU/h |
| Heats down to | −20 °C | −20 °C | −30 °C |
| Indoor sound, lowest speed | 29 dB(A) | 29 dB(A) | 23 dB(A) |
| Outdoor sound | 53 dB(A) | 54 dB(A) | 55 dB(A) |
| Outdoor unit (W × H × D) | 30.5 × 21 × 12.5 in.70 lb | 33 × 21 × 13 in.confirmed in the quote | 35 × 24 × 15 in.97 lb |
| MCA · MOCP | 9 A · 15 A | 9 A · 15 A | 13 A · 20 A |
| Refrigerant vapour line (liquid 1/4 in.) | 3/8 in. | 1/2 in. | 1/2 in. |
| Max. line length | 65 ft | 65.5 ft | 65.5 ft |
| CS532AH adapter | CS532AH adapter | Built in | |
| Remote | DRCPX | DRCPX | DRCZ |
| Item | P Series | X Series | Z Series |
|---|---|---|---|
| Models | DHP18NWB21SDHP18CSB21S | DHX18NWB21SDHX18CSB21S | DHZ18NWB21SDHZ18CSB21S |
| SEER · EER · HSPF | 16 · 9 · 9 | 20 · 12.5 · 10 | 21 · 12.5 · 10.5 |
| Rated heating at 8.3 °C | 19,000 BTU/hmax. 23,498 | 19,800 BTU/hmax. 23,498 | 19,000 BTU/hmax. 24,566 |
| Rated cooling | 18,000 BTU/h | 18,000 BTU/h | 18,000 BTU/h |
| Heats down to | −20 °C | −20 °C | −30 °C |
| Indoor sound, lowest speed | 35 dB(A) | 35 dB(A) | 26 dB(A) |
| Outdoor sound | 56 dB(A) | 55 dB(A) | 59 dB(A) |
| Outdoor unit (W × H × D) | 38 × 28 × 16 in.96 lb | 38 × 28 × 16 in.114 lb | 39 × 31 × 17 in.141 lb |
| MCA · MOCP | 16 A · 25 A | 16 A · 25 A | 19 A · 30 A |
| Refrigerant vapour line (liquid 1/4 in.) | 1/2 in. | 5/8 in. | 5/8 in. |
| Max. line length | 82 ft | 82 ft | 82 ft |
| CS532AH adapter | CS532AH adapter | Built in | |
| Remote | DRCPX | DRCPX | DRCZ |
| Item | P Series | X Series |
|---|---|---|
| Models | DHP24NWB21SDHP24CSB21S | DHX24NWB21SDHX24CSB21S |
| SEER · EER · HSPF | 16 · 9.75 · 9 | 20 · 12.5 · 10 |
| Rated heating at 8.3 °C | 23,000 BTU/hmax. 26,000 | 23,000 BTU/hmax. 30,708 |
| Rated cooling | 22,000 BTU/h | 22,000 BTU/h |
| Heats down to | −20 °C | −20 °C |
| Indoor sound, lowest speed | 36 dB(A) | 36 dB(A) |
| Outdoor sound | 59 dB(A) | 59 dB(A) |
| Outdoor unit (W × H × D) | 38 × 28 × 16 in.confirmed in the quote | 39 × 31 × 17 in.142 lb |
| MCA · MOCP | 16 A · 25 A | 20 A · 30 A |
| Refrigerant vapour line (liquid 1/4 in.) | 5/8 in. | 5/8 in. |
| Max. line length | 82 ft | 82 ft |
| CS532AH adapter | CS532AH adapter | |
| Remote | DRCPX | DRCPX |
No Z Series at 24,000 BTU/h. At this size the P and the X have the same rated capacities and the same 42 × 13 × 10 in. indoor cabinet; the X is rated 20 SEER versus 16.
In green, the best value in the row. On 115 V, only the P and the X exist (9,000 and 12,000 BTU/h); at 30,000 and 36,000 BTU/h, only the P. Source: YORK 2020 catalogue, AHRI 210/240 ratings.
YORK designs the wall unit; AirGreen mounts it on the right wall.
AirGreen picks the series and size with you, finds the spot for the indoor and outdoor units, then installs everything.
What YORK brings
- Three wall seriesP, X and Z, from 16 to 28 SEER and 9,000 to 36,000 BTU/h depending on the series.
- ETL listingMini-splits Intertek ETL listed for Canada and the USA, according to YORK.
- YORK accessoriesPhotocatalytic and active carbon filters, wall brackets rated for 176 and 300 lb.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the insulation, the electrical service and the refrigerant line route.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: the right series, at the right size, mounted on the right wall by AirGreen.
All 17 YORK wall units, right below.
Filter by series or size; each listing gives the model numbers and the AHRI number.
Your room, the series that fits it.
Five situations we often see, and what YORK’s figures say for each. The exact size is chosen at the visit.
They are the only two YORK wall sizes in our catalogue above 24,000 BTU/h: 28,400 and 34,600 BTU/h of rated heating at 8.3 °C, and up to 98.5 ft of line set.
See the P Series →On 115 V, the X is rated 23 and 22 SEER, the P 16. The required circuit runs from 12 to 20 A (MCA) depending on the model: we check it at the visit, along with the electrical panel.
See the X Series →At its lowest speed, the 9,000 BTU/h Z indoor unit goes down to 22 dB(A), versus 28 (P) and 29 (X) on 208/230 V. Sound pressure levels published by YORK.
See the Z Series →The Z’s heating range goes down to −30 °C, the P’s and X’s to −20 °C. YORK claims “80%” of heating capacity at −30 °C (−22 °F) for the Z, without stating the reference capacity.
See the Z Series →The Z has
What all three series share.
Standard features YORK’s catalogue ticks for the P, the X and the Z, plus a few options.
iFeel function: according to YORK, the room temperature is measured at the remote, where you are, rather than at the indoor unit.
P · X · ZIntelligent Preheating: according to YORK, in heating the indoor fan waits until the coil is warm before it blows.
P · X · ZIntelligent Defrosting is a standard feature of all three series; for the X, YORK adds that it defrosts only when needed.
P · X · ZSoft Start and Auto Restart are among the standard features of all three wall series.
P · X · ZPhotocatalytic and active carbon filters, offered by YORK for the P, X and Z Series.
P · X · ZYORK mini-splits are Intertek ETL listed (Canada and USA) to ANSI/UL 1995 and CAN/CSA C22.2 No. 236-11, and AHRI certified, according to YORK.
Full rangeWhat the installer checks before drilling the wall.
The limits shared by all three series, then the line length allowed for each size.
| Size | P | X | Z |
|---|---|---|---|
| 9,000 BTU/h | 49.2 ft | 49.2 ft | 49.2 ft |
| 12,000 BTU/h | 65 ft | 65.5 ft | 65.5 ft |
| 18,000 BTU/h | 82 ft | 82 ft | 82 ft |
| 24,000 BTU/h | 82 ft | 82 ft | — |
| 30,000 and 36,000 BTU/h | 98.5 ft | — | — |
1/4 in. liquid line on every model. The catalogue refers to YORK’s submittals for exact port sizes; we confirm them before the installation.
The catalogue’s terms, in plain words.
Seasonal cooling efficiency under the pre-2023 edition of AHRI 210/240, used in YORK’s 2020 catalogue. It does not compare directly with the SEER2 of central systems.
Cooling efficiency at a single test point, 35 °C (95 °F) outdoors.
Seasonal heating efficiency, on the same basis as SEER. The higher, the less heating costs.
A-weighted sound pressure level. The catalogue gives the indoor unit’s at each speed, and the outdoor unit’s.
Minimum circuit ampacity and maximum overcurrent protection: the two values that size the electrical circuit.
The outdoor temperatures within which YORK publishes heating operation: down to −20 °C for the P and the X, −30 °C for the Z.
LogisVert and ENERGY STAR: none of the YORK wall units we carry.
None of the 17 AHRI numbers on our YORK wall-unit listings is on
What people ask us about YORK wall units.
Which YORK wall unit heats in the deepest cold?
The Z Series: its heating range goes down to −30 °C, versus −20 °C for the P and X Series. Below those temperatures the unit is outside the range YORK publishes; we take that into account when choosing backup heat at the visit.
Does a YORK wall unit qualify for LogisVert?
Not ours: none of the 17 AHRI numbers on our YORK wall-unit listings is on
Can a YORK wall unit run on a 115 V circuit?
Yes, at 9,000 and 12,000 BTU/h, in the P and X Series. The required circuit runs from 12 to 20 A (MCA) depending on the model; we check it against your electrical panel at the visit.
How do I control a YORK wall unit from my phone?
The Z Series has
Why does this page use SEER, and the central systems page SEER2?
YORK’s wall unit catalogue gives SEER, EER and HSPF ratings under the pre-2023 edition of AHRI 210/240; central systems are rated in SEER2 and HSPF2 under the 2023 edition, as listed by ENERGY STAR. The two scales do not compare directly.
What size wall unit for my room?
We choose it at the free visit, from the room’s area, insulation, windows and use. YORK sizes run from 9,000 to 18,000 BTU/h in the Z Series, up to 24,000 in the X Series and up to 36,000 in the P Series.
Your YORK wall unit, chosen for the room and mounted by AirGreen.
At the free visit, we measure the room, choose the series and size, and check the line-set route and the electrical circuit.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): P, X and Z Series (pp. 9 to 16), features (p. 8), controls and accessories (pp. 40 to 44), listing and warranty (pp. 3 and 4); copy in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
- Environment and Climate Change Canada,
1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026. - airgreen.ca product pages: model and AHRI numbers of the units we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.