YORK · R Series ducted YORK at AirGreenSold and installed by AirGreen in Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full YORK range
AirGreen × YORKSold and installed by AirGreenR Series ductedMedium static pressureDWCR control supplied18,000 to 48,000 BTU/hMontreal · Laval · Longueuil · South Shore · North Shore
01 · Model by model

Six ducted units, 18,000 to 48,000 BTU/h, complete system.

Select a size: the indoor unit, the R Series outdoor unit that goes with it, and what the installation needs.

Size
DHR24NDB21S + DHR24CSB21SDucted · 24,000 BTU/h · AHRI 8578433
See the product page →
Rated cooling
23,800 BTU/hrange 8,200 to 29,000
Heating at 8.3 °C
27,200 BTU/hrange 8,200 to 32,400
SEER · EER · HSPF
16 · 10.65 · 10
Heats
down to −18 °C
Indoor unit
50 × 21 × 11 in.75 lb · max. airflow 826 CFM
Static pressure
0-0.3 in. W.G.2020 edition: 0-0.8
Indoor sound
47 → 40 dB(A)highest → lowest speed
Outdoor unit
39 × 31 × 17 in.152 lb · 57 dB(A)
Circuits (separate)
24 A · 40 Aoutdoor MCA · MOCP; indoor MCA 2 A
Liquid · vapour lines
3/8 · 5/8 in.1 in. drain
Max. length · lift
164 ft · 49.2 ft
Factory charge
77.6 oz

System SEER, EER and HSPF ratings under AHRI 210/240, heating rated at 8.3 °C (47 °F), as printed by YORK. Dimensions in inches: indoor unit width × depth × height; outdoor unit width × height × depth; net weights. The min. to max. ranges are those of the R Series outdoor unit in the 2020 catalogue. YORK’s per-form documents can give slightly different ranges: we confirm the system’s range in the quote. YORK requires separate power for the indoor and outdoor units.

02 · Three forms, one outdoor unit

The ducted unit versus the cassette and floor-ceiling units.

On the same R Series outdoor unit, the indoor form changes efficiency, airflow and sound. Size for size:

Size
The three R Series forms at 24,000 BTU/h
ItemDucted4-way cassetteFloor-ceiling
SEER162016
EER10.6510.6510.65
HSPF101010
Rated heating at 8.3 °C27,200 BTU/h27,200 BTU/h27,200 BTU/h
Max. airflow826 CFM767 CFM708 CFM
Indoor sound at lowest40 dB(A)38 dB(A)40 dB(A)
Indoor unit weight75 lb60 lb88 lb

In green, the best value in the row. Same outdoor unit for all three forms. See also: 4-way cassette · Floor-ceiling.

AirGreen × YORK

YORK designs the ducted unit; AirGreen lays out the ducts.

AirGreen measures the duct route and grille resistance, checks that the duct system stays within YORK’s static pressure range, then installs everything.

YORK

What YORK brings

  • Medium static pressure0.12 to 0.5 in. W.G. depending on size (later edition).
  • DWCR wall controlSupplied with the unit.
  • Built-in condensate pumpTo a 1 in. drain, according to YORK.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free visitWe measure the installation space, the electrical service, and the route for the refrigerant lines and the drain.
  • Clear quoteThe exact model, what is included and the price, in writing.
  • RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.

The result: an invisible unit, discreet grilles, installed by AirGreen.

The YORK shop · Ducted

All 6 YORK ducted units, right below.

One listing per size, with the indoor unit, the outdoor unit and the AHRI number.

YORK
03 · Static pressure

How far the ducted unit can push air through the ducts.

Available static pressure says how much duct and grille resistance the fan can overcome. YORK published it twice, with different values.

R Series ducted available static pressure, two YORK editions
SizeLater edition2020 catalogueMax. airflow
18,000 BTU/h0-0.12 in. W.G.0-0.4 in. W.G.588 CFM
24,000 BTU/h0-0.3 in. W.G.0-0.8 in. W.G.826 CFM
30,000 BTU/h0-0.3 in. W.G.0-0.8 in. W.G.826 CFM
36,000 BTU/h0-0.4 in. W.G.0-0.8 in. W.G.1,180 CFM
42,000 BTU/h0-0.4 in. W.G.0-0.8 in. W.G.1,180 CFM
48,000 BTU/h0-0.5 in. W.G.0-0.8 in. W.G.1,475 CFM
  • YORK describes the R Series ducted unit as medium static pressure (“Medium static pressure capability”).
  • The two YORK catalogue editions do not give the same range: we use the later, more conservative one, and design the ducts accordingly.
  • We measure the duct route and grille resistance at the visit, before choosing the size.
04 · Features

What YORK builds into the ducted unit.

DWCR wall control as standard

The ducted unit is set with the DWCR wired wall control, supplied.

Built-in condensate pump

“Internal condensate drain pump”, to a 1 in. drain.

Grilles and diffusers

Air goes through ducts and ceiling or wall grilles: we propose the grilles and diffusers in the quote.

Optional DWCR2

Wired wall control offered by YORK for the R Series, as an option.

05 · Before you choose

What to know about the ducted unit before you sign.

0.12 to 0.5 in. W.G.of available static pressure by size (later edition): we measure your duct system before choosing.
1 to 5 Aindoor unit MCA, on a circuit separate from the outdoor unit’s, according to YORK.
−18 °Cheating limit of the ducted unit, as for the whole R Series: backup heat is planned in the quote.
0/6AHRI numbers of our ducted units on the October 26, 2026 LogisVert list or at ENERGY STAR.
  • The DWCR wall control is supplied: we choose its location with you at the visit.
Frequently asked questions

What people ask us about the YORK ducted unit.

Can the R Series ducted unit replace an electric ducted furnace?

Not always: it delivers air through ducts, but YORK rates it at medium static pressure: 0.12 to 0.5 in. W.G. depending on size in the later edition. For an existing duct system, we measure its resistance before proposing anything. If the furnace burns gas or oil, its removal is handled by a partner holding the required RBQ licence.

What efficiency does the ducted unit have?

16 SEER at all six sizes, with an HSPF of 9 to 10. The R Series’ “up to 20 SEER” comes from the cassette, at 24,000 and 30,000 BTU/h.

How is it controlled?

With the DWCR wired wall control, supplied; the DWCR2 is offered as an option.

Does the ducted unit heat alone all winter?

No: its heating range stops at −18 °C (0 °F), like the whole R Series. We keep the existing backup heat or plan one in the quote, depending on the house.

Does the R Series ducted unit qualify for LogisVert?

No: none of the 6 AHRI numbers on our listings is on Hydro-Québec’s October 26, 2026 list. So we promise no amount.

Sources and dates checked

  1. YORK, Mini-Split Systems catalogue PUBL-7782v6 (November 2020): R Series, outdoor unit (p. 17), cassette (p. 18), ducted (p. 19), floor-ceiling (p. 20), controls (pp. 40 to 43); copy in our documents, re-read October 26, 2026.
  2. YORK, R Series ducted unit, later catalogue edition (folios 15 and 17, copy in our documents): available static pressure; re-read October 26, 2026.
  3. Hydro-Québec, LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.
  4. ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
  5. Environment and Climate Change Canada, 1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026.
  6. airgreen.ca product pages: model and AHRI numbers of the systems we carry, read October 26, 2026.

Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.