AirGreenYORK
YORK · Central heat pumps YORK at AirGreenSold and installed by AirGreen in Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full YORK range
AirGreen × YORKSold and installed by AirGreenENERGY STAR Canada matched systemsHH8: cold climateYORK JHE air handlerR-454B refrigerantMontreal · Laval · Longueuil · South Shore · North Shore
01 · Two families

The two YORK central systems in our catalogue, two ways to heat.

Same brand, same indoor family; what changes is the compressor, the discharge direction and cold-weather performance.

02 · At equal tonnage

The YH5 and the HH8 side by side, from performance to dimensions.

At 2 and 3 tons both families pair with the same JHE air handler; at 5 tons our listings pair two different indoor units. The “Difference” column reads HH8 minus YH5.

Tonnage
YH5 LX and HH8 at 3 tons
ItemYH5 LXHH8Difference
Certified pairingYH536E2S11 + JHE36B5CD2SS1HH836E2S11 + JHE36B5CD2SS1Same indoor unit
AHRI number214427016215853295
CompressorTwo-stage scroll Twin rotary, variable speed
DischargeTop Side
Heating capacity at 8.3 °C (47 °F)31,800 BTU/h31,800 BTU/h0
Heating capacity at −8.3 °C (17 °F)21,000 BTU/h28,400 BTU/h+7,400
Heating capacity at −15 °C (5 °F)17,600 BTU/h26,000 BTU/h+8,400
Max. output at −25 °C (−13 °F)Not published: not on the NEEP list as of Oct. 27, 202616,500 BTU/h (NEEP)
COP at −15 °C2.02.0
SEER2 · EER215.2 · 11.019.0 · 11.0+3.8 SEER2
HSPF2 (ENERGY STAR)8.19.0+0.9
ENERGY STAR cold climateNoYes
Dimensions A × B × C (in.)36 1/4 × 29 1/4 × 29 1/434 4/9 × 43 1/3 × 17 5/7
Operating weight176 lb185.2 lb+9.2 lb
Min. circuit ampacity (MCA) · max. overcurrent protection20.4 A · 30 A30 A · 35 A
Liquid · vapour lines (in.)3/8 · 3/43/8 · 3/4
Factory charge (15 ft) · per foot5 lb 1 oz · 0.57 oz/ft7 lb 7 oz · 0.57 oz/ft
LogisVert (Hydro-Québec)$1,050$3,408+$2,358

Only the YH5 LX is in our catalogue at 1.5 and 4 tons. Dimensions A × B × C as printed by YORK; A is the height (labelled for the HH8, inferred from the table for the YH5). Sources: YORK YH5 and HH8 technical guides (tables 3 and 4), read October 14, 2026; ENERGY STAR (dataset w7cv-9xjt) and Hydro-Québec’s LogisVert list, re-read October 26, 2026; NEEP, re-read October 27, 2026.

AirGreen × YORK

YORK designs the central system; AirGreen installs it in your home.

AirGreen measures the house, picks the family and the tonnage with you, then installs the outdoor unit and the air handler.

YORK

What YORK brings

  • One indoor family: the JHEEach pair, outdoor unit plus JHE, has its own AHRI number.
  • R-454B refrigerantIn both families, with a refrigerant detection system (RDS) factory-installed in the JHE.
  • Electric backup heat by kit8HK electric heat kits for the JHE, for an all-electric system.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free visitWe measure the rooms, the ducts, the insulation and the electrical service.
  • Clear quoteWith the AHRI number and the indicative LogisVert amount.
  • RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.

The result: the right family and tonnage, chosen at your home and installed by AirGreen.

The YORK shop · Central heat pumps

All 8 YORK central systems, right below.

Filter by tonnage or series, then open the product page: each one gives the matched system, the AHRI number and the LogisVert amount.

YORK
03 · The system

Outside, the YORK unit. Inside, the JHE air handler.

A YORK central heat pump is two units certified together under one AHRI number: the one in the yard and the one in the house, in the basement or a closet. LogisVert excludes an indoor unit or ducts installed outside the insulated envelope, in the attic for example.

Outside

YH5 LX

  • Top discharge, base from 24 × 24 in. (1.5 tons) to 35 1/4 × 31 3/4 in. (4 and 5 tons).
  • 124 to 255 lb operating weight.
  • Crankcase heater and discharge muffler factory-installed on every model.
Outside

HH8

  • Side discharge: 13 to 17 5/7 in. deep, up to 57 1/2 in. tall (5 tons).
  • 116.8 to 244.7 lb operating weight.
  • Crankcase heater and base-pan heater as standard; the YH5 guide mentions no base-pan heater.
Inside

YORK JHE air handler

  • Multiposition: upflow, downflow or horizontal; 21 in. deep at most.
  • Nine-speed ECM blower, MaxAlloy™ “A” coil, factory-installed TXV.
  • Total air leakage of 2% or less; 1 in. filter.
  • At 4 and 5 tons, optional JSE short cabinet: upflow only, 57 in. tall at most. That is a different pairing: its AHRI number and LogisVert eligibility are checked on the quote.

Thermostat: YORK lists conventional controls for both families, and ENERGY STAR lists no connected function for either.

04 · Deep cold

In deep cold, how much of its heating capacity each family keeps.

Four test points are published: 8.3 °C, −8.3 °C and −15 °C by ENERGY STAR; −25 °C by NEEP. Nothing is published between these points, and we don’t estimate any. The bar shows the share of the 8.3 °C capacity that remains.

Tonnage
HH8HH836E2S1126,000 BTU/h82% of its 8.3 °C capacity
YH5 LXYH536E2S1117,600 BTU/h55% of its 8.3 °C capacity
Montréal–Trudeau, 1981-2010 normals

The average January daily low is −14.0 °C: the −15 °C test point matches an ordinary January night.

Below −25 °C, no value is published in the sources we read: we size the backup heat at the visit.

Sources: ENERGY STAR (dataset w7cv-9xjt), re-read October 26, 2026; NEEP, re-read October 27, 2026; Environment and Climate Change Canada (station 7025250), read October 14, 2026.

05 · Technician’s corner

What the electrician and the refrigeration tech check first.

Values from the YORK YH5 and HH8 technical guides (tables 3 and 4), model by model. Dimensions A × B × C in inches, as printed: A is the height, from the bottom of the base pan to the top of the fan guard; B and C are the sides, screw heads included.

Outdoor unit physical and electrical data
Outdoor unitTonnageMin. circuit ampacity (MCA)Max. overcurrent protectionLiquid · vapour lines (in.)Factory charge (15 ft)Per footWeightA × B × C (in.)Fan
YH518E2S11+ JHE18B5AB2SS11.5 tons9.2 A15 A3/8 · 3/43 lb 12 oz0.57 oz/ft124 lb36 1/4 × 24 × 242,100 CFM
HH824E2S11+ JHE24B5AC2SS12 tons22 A25 A3/8 · 5/85 lb 1 oz0.54 oz/ft116.8 lb29 1/2 × 35 3/7 × 13 2/52,235 CFM
YH524E2S11+ JHE24B5AC2SS12 tons15.0 A25 A3/8 · 3/45 lb 4 oz0.57 oz/ft162 lb30 × 29 1/4 × 29 1/42,900 CFM
HH836E2S11+ JHE36B5CD2SS13 tons30 A35 A3/8 · 3/47 lb 7 oz0.57 oz/ft185.2 lb34 4/9 × 43 1/3 × 17 5/73,350 CFM
YH536E2S11+ JHE36B5CD2SS13 tons20.4 A30 A3/8 · 3/45 lb 1 oz0.57 oz/ft176 lb36 1/4 × 29 1/4 × 29 1/43,055 CFM
YH548E2S11+ JHE48C5CG2SS14 tons27.2 A45 A3/8 · 7/88 lb 6 oz0.60 oz/ft232 lb39 1/2 × 35 1/4 × 31 3/44,000 CFM
HH860E2S11+ JHE60C5CH2SS15 tons37 A45 A3/8 · 7/811 lb0.6 oz/ft244.7 lb57 1/2 × 38 2/5 × 134,820 CFM
YH560E2S11+ JHE60D5CH2SS15 tons33.7 A50 A3/8 · 1 1/8 (adapter, 7/8 valve)10 lb 5 oz0.67 oz/ft255 lb39 1/2 × 35 1/4 × 31 3/43,975 CFM
  • Power: 208/230 V, single phase, 60 Hz; normal range 187 to 252 V (AHRI 110, range A). Dual-element (time-delay) fuses or HACR breaker.
  • Charge: the unit ships charged for the smallest matched indoor unit and 15 ft of lines. For another length, add or remove refrigerant by the difference between the actual (not equivalent) length and 15 ft, times the per-foot value.
  • YH518 (1.5 tons): installation rules specific to the rotary compressor, detailed on the YH5 LX page.
  • Not published in the YORK documents we read: maximum length and lift for the other models, clearances, operating range.
06 · R-454B

Both families use R-454B.

470GWP of R-454B

According to ENERGY STAR; YORK prints 467 in the YH5 guide.

78%Lower warming potential

Up to 78% lower GWP than R-410A, according to YORK, with similar pressures.

RDSRefrigerant detection

YORK factory-installs a refrigerant detection system (RDS) on the relevant equipment, including the JHE air handler. Local codes may require extra training or equipment.

Sources: YORK guides and “R-454B” page (in our documents), read October 14, 2026; ENERGY STAR, dataset w7cv-9xjt, re-read October 26, 2026.

07 · Glossary

The words on the spec sheet, in plain language. Tap or click a card.

SEER2

Seasonal cooling efficiency under the current test method; the “2” sets it apart from the old SEER. The higher it is, the less cooling costs.

HSPF2

Seasonal heating efficiency, calculated for a climate region: region V stands for a colder climate than region IV. NEEP lists both for the HH8.

COP

Heat delivered divided by electricity used, at a given temperature. A COP of 2 gives twice as much heat as electricity.

Two-stage

The YH5’s scroll compressor, from 2 tons up, runs at two capacities.

Variable speed

The HH8’s inverter-driven compressor adjusts its speed continuously; YORK states 35 to 100% of capacity.

Air handler

The indoor section: blower, coil and, when needed, an electric heat kit.

AHRI number

The certificate of one exact pairing, outdoor and indoor unit. Hydro-Québec looks this number up in its LogisVert list.

ENERGY STAR cold climate

The ENERGY STAR mention for heat pumps that meet cold-weather performance criteria.

08 · LogisVert

LogisVert: 8 central systems on Hydro-Québec’s list, from $545 to $4,440.

Amounts from Hydro-Québec’s October 26, 2026 list, “homeowner, existing house” profile, by AHRI number.

YH518E2S11+ JHE18B5AB2SS1 · AHRI 215820367
$545
10,900 BTU/h at −8.3 °C × $50 ÷ 1,000
HH824E2S11+ JHE24B5AC2SS1 · AHRI 214396076
$2,136
17,800 BTU/h at −8.3 °C × $120 ÷ 1,000
YH524E2S11+ JHE24B5AC2SS1 · AHRI 214424696
$720
14,400 BTU/h at −8.3 °C × $50 ÷ 1,000
HH836E2S11+ JHE36B5CD2SS1 · AHRI 215853295
$3,408
28,400 BTU/h at −8.3 °C × $120 ÷ 1,000
YH536E2S11+ JHE36B5CD2SS1 · AHRI 214427016
$1,050
21,000 BTU/h at −8.3 °C × $50 ÷ 1,000
YH548E2S11+ JHE48C5CG2SS1 · AHRI 214424698
$1,520
30,400 BTU/h at −8.3 °C × $50 ÷ 1,000
HH860E2S11+ JHE60C5CH2SS1 · AHRI 215853276
$4,440
37,000 BTU/h at −8.3 °C × $120 ÷ 1,000
YH560E2S11+ JHE60D5CH2SS1 · AHRI 214424699
$1,925
38,500 BTU/h at −8.3 °C × $50 ÷ 1,000

Hydro-Québec’s guide says −8 °C: each amount in this section equals the certified capacity at −8.3 °C (17 °F), times the rate per 1,000 BTU/h.

These amounts apply to the exact pairing on each product page. If you keep a furnace, use the JSE short cabinet or set the HH860 to 4 tons, the system is no longer that pairing: we check its eligibility, AHRI number and amount on the quote.

9-month deadline and program rules: YORK page, LogisVert section

Frequently asked questions

What people ask us about YORK central systems.

YH5 or HH8: which one for a Montreal house?

If deep-cold heating matters most, the HH8: its matched systems are ENERGY STAR cold-climate certified and keep 72 to 82% of their heating capacity from 8.3 °C to −15 °C, compared with 49 to 55% for the YH5 LX. At 1.5 tons, our catalogue only has the YH5 LX: our HH8 starts at 2 tons. The tonnage is set at the free visit.

Do the YH5 and the HH8 use the same indoor unit?

At 2 and 3 tons, yes: the JHE24B5AC2SS1 and JHE36B5CD2SS1 serve both families. At 5 tons, our listings pair the YH560 with the JHE60D5CH2SS1 and the HH860 with the JHE60C5CH2SS1. Each matched system has its own AHRI number.

Can I keep my gas furnace?

YORK allows pairing the YH5 and the HH8 with a gas furnace, and for the HH8, even one of another brand. The indoor unit is then no longer the JHE on our list: LogisVert eligibility, the AHRI number and the amount of that combination are checked on the quote. Gas work goes to a partner holding the proper RBQ licence.

Why does the HH8 get more LogisVert than the YH5?

Hydro-Québec’s LogisVert guide sets $120 per 1,000 BTU/h at −8 °C for an ENERGY STAR cold-climate heat pump, and $50 for an ENERGY STAR heat pump. At 3 tons, the October 26, 2026 list gives $3,408 for the HH8 and $1,050 for the YH5 LX.

Sources and dates checked

  1. ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, 8 YORK records (IDs 3713095, 3627807, 4498100, 3627809, 3627810, 3437360, 3715161, 3715141), Canadian market, read October 14, 2026, re-read October 26, 2026; “Most Efficient” designation re-checked October 27, 2026.
  2. NEEP, Cold Climate Air Source Heat Pump List, AHRI certificates 214396076, 215853295 and 215853276, read October 14, 2026, re-read October 27, 2026 (no YH5 listed).
  3. Hydro-Québec, LogisVert eligible heat pump search tool, file of October 26, 2026, “homeowner, existing house” profile.
  4. Hydro-Québec, LogisVert participation guide for residential customers, version 1.10 of September 15, 2026 (9-month deadline, p. 5; ineligible work, p. 14; rates, p. 15), read October 14, 2026.
  5. YORK, YH5 and HH8 technical guides, tables 3 and 4 (copies in our documents).
  6. YORK, “Air handlers” and “R-454B” pages of the technical guides (copies in our documents).
  7. YORK, HH8, YH5 and JHE product pages, and HH8 (PUBL-3444-C-0124) and JHE/JME (PUBL-3457-B-0324) sell sheets, read October 14, 2026.
  8. Environment and Climate Change Canada, 1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026.
  9. airgreen.ca product pages: the matched systems we carry and the links to them.

LogisVert amounts are indicative, from Hydro-Québec’s October 26, 2026 list. Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.