AirGreenYORK
YORK · YH5 LX central heat pump YORK at AirGreenSold and installed by AirGreen in Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full YORK range
AirGreen × YORKSold and installed by AirGreenENERGY STARTwo-stage from 2 tonsTop dischargeR-454B refrigerantMontreal · Laval · Longueuil · South Shore · North Shore
01 · Your tonnage

Five tonnages, from 1.5 to 5 tons, all at 15.2 SEER2.

Select a tonnage: its certified pairing, its heating capacity at three temperatures, its LogisVert amount and what the installer must plan for.

Tonnage
YH536E2S11 + JHE36B5CD2SS13 tons · AHRI 214427016 · ENERGY STAR 4498100
See the product page →
8.3 °C47 °F31,800
−8.3 °C17 °F21,000
−15 °C5 °F17,600

BTU/h certified by ENERGY STAR; COP at −15 °C: 2.0

SEER2 · EER2 · HSPF2
15.2 · 11.0 · 8.1
Compressor
Two-stage scroll
Certified cooling
32,400 BTU/h
LogisVert
$1,050
MCA · MOCP
20.4 A · 30 A
Operating weight
176 lb
A × B × C
36 1/4 × 29 1/4 × 29 1/4 in.as printed by YORK
Liquid · vapour lines
3/8 · 3/4 in.
Factory charge (15 ft) · per foot
5 lb 1 oz · 0.57 oz/ft
Fan
3,055 CFM

Capacities, ratings and COP: ENERGY STAR. Electrical, weight, dimensions, lines, charge and fan: YORK YH5 technical guide (tables 3 and 4). Each pairing is our listing’s, with its JHE air handler.

02 · Two compressors

1.5 tons on one side, 2 to 5 tons on the other: two different mechanisms.

YORK keeps the two-stage compressor for 2-ton and larger models. The YH518 has its own installation rules.

YH5181.5 tons

Single-stage rotary compressor, with a factory-installed hard-start kit.

Piping100 ft equivalent at most, “with no exceptions”FanPSC, 0.083 hp, 18 in.Compressor current6.7 A (RLA); 33.0 A locked rotorEER212.5
YH524 → YH5602 to 5 tons

Two-stage scroll compressor; 10106 hard-start kit available as an accessory.

Pipingmaximum length not publishedFanECM, 0.33 hp, 22 or 24 in.Compressor current10.2 to 25.2 A (RLA)EER211.0 to 12.0
AirGreen × YORK

The YH5 LX, designed by YORK, installed by AirGreen.

AirGreen picks the tonnage with you, from 1.5 to 5 tons, and installs the outdoor unit with its JHE air handler.

YORK

What YORK brings

  • Five ENERGY STAR tonnagesFrom 1.5 to 5 tons, 15.2 SEER2.
  • Two-stage from 2 tonsScroll compressor; single-stage rotary at 1.5 tons.
  • Galvanized buildG90 chassis, powder coat, protected coil.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free visitWe measure the rooms, the ducts, the insulation and the electrical service.
  • Clear quoteWith the AHRI number and the indicative LogisVert amount.
  • RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.

The result: a YH5 LX at the right tonnage, with its JHE, installed by AirGreen.

The YORK shop · YH5 LX

All 5 YH5 LX systems, right below.

One listing per tonnage, each with its JHE air handler, its AHRI number and the LogisVert amount.

YORK
03 · Construction

What YORK’s technical guide builds into every YH5.

Galvanized chassis, powder coat

G90-equivalent galvanized steel chassis parts, coated external fasteners, powder-coated panels, according to YORK.

Protected coil

Extruded louver coil guard; aluminum fins mechanically bonded to copper tubing.

Protected compressor

Internal high-pressure relief valve and temperature sensor; system high- and low-pressure switches.

Top discharge

Warm air goes up, away from the house and the landscaping, according to YORK.

Standard on all five

Crankcase heater and external discharge muffler; TXV; filter-drier shipped loose, installed in the field.

QR code on the unit

It leads to the technical documents and warranty information, according to YORK.

04 · Technician’s corner

The table 3 values the central systems page does not give.

YH5 LX: compressor, circuit, fan and coil
ModelCompressor: rated load amps (RLA) · locked rotor amps (LRA)MCA · MOCPMin. overcurrentFan motorCoil: face area · rows · fins/in.
YH518E2S111.5 tons6.7 A · 33.0 A9.2 A · 15 A15 APSC, 0.083 hp, 1,000 rpm14.50 sq ft · 1 · 22
YH524E2S112 tons10.2 A · 62.0 A15.0 A · 25 A15 AECM, 0.33 hp, 834 rpm14.60 sq ft · 1 · 22
YH536E2S113 tons14.5 A · 76.0 A20.4 A · 30 A25 AECM, 0.33 hp, 875 rpm17.90 sq ft · 1 · 22
YH548E2S114 tons20.0 A · 141.0 A27.2 A · 45 A30 AECM, 0.33 hp, 917 rpm23.80 sq ft · 1 · 22
YH560E2S115 tons25.2 A · 147.3 A33.7 A · 50 A35 AECM, 0.33 hp, 875 rpm23.80 sq ft · 2 · 18
  • Power: 208/230 V, single phase, 60 Hz, normal range 187 to 252 V; dual-element fuses or HACR breaker.
  • YH560: 1 1/8 in. vapour line, with a field-installed adapter fitting on the 7/8 in. valve.
  • Not published in the guide: clearances, operating range, maximum length of the scroll models.
05 · LogisVert

Each amount, worked out in front of you.

YH5 LX LogisVert amounts
PairingCapacity at −8.3 °CCalculationAmount (Oct. 26 list)
YH518E2S111.5 tons10,900 BTU/h10,900 × $50 ÷ 1,000$545
YH524E2S112 tons14,400 BTU/h14,400 × $50 ÷ 1,000$720
YH536E2S113 tons21,000 BTU/h21,000 × $50 ÷ 1,000$1,050
YH548E2S114 tons30,400 BTU/h30,400 × $50 ÷ 1,000$1,520
YH560E2S115 tons38,500 BTU/h38,500 × $50 ÷ 1,000$1,925
  • The YH5 LX is ENERGY STAR certified, without the cold-climate mention: LogisVert applies the base rate. The cold-climate HH8 gets $120 per 1,000 BTU/h; the difference is on the central systems page.
  • These amounts apply to each listing’s YH5 + JHE pairing. If you keep a furnace, we check eligibility, the AHRI number and the amount on the quote.
Frequently asked questions

What people ask us about the YH5 LX.

Does the 1.5-ton YH5 have two stages?

No. The YH518 has a single-stage rotary compressor and a factory-installed hard-start kit; YORK keeps two-stage operation for models of 2 tons and up.

How far can the YH518 sit from the house?

YORK’s guide limits rotary-compressor models to 100 ft of equivalent piping, with no exceptions. For the other tonnages, the maximum length is not published in the guide.

Is the YH5 LX cold-climate certified?

No: ENERGY STAR certifies it without the cold-climate mention, and NEEP does not list it. At −15 °C its pairings keep 49 to 55% of their certified 8.3 °C capacity. For deep cold, see the HH8.

Why choose the YH5 at 4 tons?

Because it is our only 4-ton YORK split central heat pump: the YH548, paired with the JHE48C5CG2SS1, certified at 47,000 BTU/h cooling and 30,400 BTU/h at −8.3 °C.

Is the YH5 loud?

YORK claims “as low as 69 dBA” in its technical guide, with no per-model level or test conditions. So we give no figure by tonnage.

Sources and dates checked

  1. YORK, Technical Guide R-454B Outdoor Split-System Heat Pump YH5 (copy in our documents): features (p. 6), table 3 (p. 8) and table 4 (p. 9), read October 14 and re-read October 26, 2026.
  2. ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, 5 YH5 records (IDs 3713095, 3627807, 4498100, 3627809, 3627810), Canadian market, re-read October 26, 2026.
  3. NEEP, Cold Climate Air Source Heat Pump List: no YH5 listed, searched by AHRI number on October 26 and 27, 2026.
  4. Hydro-Québec, LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile; participation guide v1.10 of September 15, 2026 (rates, p. 15), read October 14, 2026.
  5. airgreen.ca product pages: matched systems we carry and AHRI numbers, read October 26, 2026.

Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.