Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
YORK YH5 LX central heat pump: ENERGY STAR from 1.5 to 5 tons, two stages from 2 tons up
The YH5 LX covers five tonnages, from 1.5 to 5 tons, all ENERGY STAR certified at 15.2 SEER2.
LogisVert, tonnage by tonnage: $545 to $1,925.
Five tonnages, from 1.5 to 5 tons, all at 15.2 SEER2.
Select a tonnage: its certified pairing, its heating capacity at three temperatures, its LogisVert amount and what the installer must plan for.
BTU/h certified by ENERGY STAR; COP at −15 °C: 2.3
- SEER2 · EER2 · HSPF2
- 15.2 · 12.5 · 7.8
- Compressor
Single-stage rotary- Certified cooling
- 17,000 BTU/h
- LogisVert
- $545
- MCA · MOCP
- 9.2 A · 15 A
- Operating weight
- 124 lb
- A × B × C
- 36 1/4 × 24 × 24 in.as printed by YORK
- Liquid · vapour lines
- 3/8 · 3/4 in.
- Factory charge (15 ft) · per foot
- 3 lb 12 oz · 0.57 oz/ft
- Fan
- 2,100 CFM
BTU/h certified by ENERGY STAR; COP at −15 °C: 2.0
- SEER2 · EER2 · HSPF2
- 15.2 · 12.0 · 7.8
- Compressor
Two-stage scroll- Certified cooling
- 24,000 BTU/h
- LogisVert
- $720
- MCA · MOCP
- 15.0 A · 25 A
- Operating weight
- 162 lb
- A × B × C
- 30 × 29 1/4 × 29 1/4 in.as printed by YORK
- Liquid · vapour lines
- 3/8 · 3/4 in.
- Factory charge (15 ft) · per foot
- 5 lb 4 oz · 0.57 oz/ft
- Fan
- 2,900 CFM
BTU/h certified by ENERGY STAR; COP at −15 °C: 2.0
- SEER2 · EER2 · HSPF2
- 15.2 · 11.0 · 8.1
- Compressor
Two-stage scroll- Certified cooling
- 32,400 BTU/h
- LogisVert
- $1,050
- MCA · MOCP
- 20.4 A · 30 A
- Operating weight
- 176 lb
- A × B × C
- 36 1/4 × 29 1/4 × 29 1/4 in.as printed by YORK
- Liquid · vapour lines
- 3/8 · 3/4 in.
- Factory charge (15 ft) · per foot
- 5 lb 1 oz · 0.57 oz/ft
- Fan
- 3,055 CFM
BTU/h certified by ENERGY STAR; COP at −15 °C: 2.1
- SEER2 · EER2 · HSPF2
- 15.2 · 11.7 · 7.8
- Compressor
Two-stage scroll- Certified cooling
- 47,000 BTU/h
- LogisVert
- $1,520
- MCA · MOCP
- 27.2 A · 45 A
- Operating weight
- 232 lb
- A × B × C
- 39 1/2 × 35 1/4 × 31 3/4 in.as printed by YORK
- Liquid · vapour lines
- 3/8 · 7/8 in.
- Factory charge (15 ft) · per foot
- 8 lb 6 oz · 0.60 oz/ft
- Fan
- 4,000 CFM
BTU/h certified by ENERGY STAR; COP at −15 °C: 2.1
- SEER2 · EER2 · HSPF2
- 15.2 · 11.7 · 7.8
- Compressor
Two-stage scroll- Certified cooling
- 55,500 BTU/h
- LogisVert
- $1,925
- MCA · MOCP
- 33.7 A · 50 A
- Operating weight
- 255 lb
- A × B × C
- 39 1/2 × 35 1/4 × 31 3/4 in.as printed by YORK
- Liquid · vapour lines
- 3/8 · 1 1/8 (adapter, 7/8 valve) in.
- Factory charge (15 ft) · per foot
- 10 lb 5 oz · 0.67 oz/ft
- Fan
- 3,975 CFM
Capacities, ratings and COP: ENERGY STAR. Electrical, weight, dimensions, lines, charge and fan: YORK YH5 technical guide (tables 3 and 4). Each pairing is our listing’s, with its JHE air handler.
1.5 tons on one side, 2 to 5 tons on the other: two different mechanisms.
YORK keeps the
The YH5 LX, designed by YORK, installed by AirGreen.
AirGreen picks the tonnage with you, from 1.5 to 5 tons, and installs the outdoor unit with its JHE air handler.
What YORK brings
- Five ENERGY STAR tonnagesFrom 1.5 to 5 tons, 15.2 SEER2.
Two-stage from 2 tonsScroll compressor;single-stage rotary at 1.5 tons.- Galvanized buildG90 chassis, powder coat, protected coil.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the ducts, the insulation and the electrical service.
- Clear quoteWith the AHRI number and the indicative LogisVert amount.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: a YH5 LX at the right tonnage, with its JHE, installed by AirGreen.
All 5 YH5 LX systems, right below.
One listing per tonnage, each with its JHE air handler, its AHRI number and the LogisVert amount.
What YORK’s technical guide builds into every YH5.
G90-equivalent galvanized steel chassis parts, coated external fasteners, powder-coated panels, according to YORK.
Extruded louver coil guard; aluminum fins mechanically bonded to copper tubing.
Internal high-pressure relief valve and temperature sensor; system high- and low-pressure switches.
Warm air goes up, away from the house and the landscaping, according to YORK.
Crankcase heater and external discharge muffler; TXV; filter-drier shipped loose, installed in the field.
It leads to the technical documents and warranty information, according to YORK.
The table 3 values the central systems page does not give.
| Model | Compressor: rated load amps (RLA) · locked rotor amps (LRA) | MCA · MOCP | Min. overcurrent | Fan motor | Coil: face area · rows · fins/in. |
|---|---|---|---|---|---|
| YH518E2S111.5 tons | 6.7 A · 33.0 A | 9.2 A · 15 A | 15 A | PSC, 0.083 hp, 1,000 rpm | 14.50 sq ft · 1 · 22 |
| YH524E2S112 tons | 10.2 A · 62.0 A | 15.0 A · 25 A | 15 A | ECM, 0.33 hp, 834 rpm | 14.60 sq ft · 1 · 22 |
| YH536E2S113 tons | 14.5 A · 76.0 A | 20.4 A · 30 A | 25 A | ECM, 0.33 hp, 875 rpm | 17.90 sq ft · 1 · 22 |
| YH548E2S114 tons | 20.0 A · 141.0 A | 27.2 A · 45 A | 30 A | ECM, 0.33 hp, 917 rpm | 23.80 sq ft · 1 · 22 |
| YH560E2S115 tons | 25.2 A · 147.3 A | 33.7 A · 50 A | 35 A | ECM, 0.33 hp, 875 rpm | 23.80 sq ft · 2 · 18 |
- Power: 208/230 V, single phase, 60 Hz, normal range 187 to 252 V; dual-element fuses or HACR breaker.
- YH560: 1 1/8 in. vapour line, with a field-installed adapter fitting on the 7/8 in. valve.
- Not published in the guide: clearances, operating range, maximum length of the scroll models.
Each amount, worked out in front of you.
| Pairing | Capacity at −8.3 °C | Calculation | Amount (Oct. 26 list) |
|---|---|---|---|
| YH518E2S111.5 tons | 10,900 BTU/h | 10,900 × $50 ÷ 1,000 | $545 |
| YH524E2S112 tons | 14,400 BTU/h | 14,400 × $50 ÷ 1,000 | $720 |
| YH536E2S113 tons | 21,000 BTU/h | 21,000 × $50 ÷ 1,000 | $1,050 |
| YH548E2S114 tons | 30,400 BTU/h | 30,400 × $50 ÷ 1,000 | $1,520 |
| YH560E2S115 tons | 38,500 BTU/h | 38,500 × $50 ÷ 1,000 | $1,925 |
- The YH5 LX is ENERGY STAR certified, without the
cold-climate mention: LogisVert applies the base rate. Thecold-climate HH8 gets $120 per 1,000 BTU/h; the difference is on the central systems page. - These amounts apply to each listing’s YH5 + JHE pairing. If you keep a furnace, we check eligibility, the AHRI number and the amount on the quote.
What people ask us about the YH5 LX.
Does the 1.5-ton YH5 have two stages?
No. The YH518 has a
How far can the YH518 sit from the house?
YORK’s guide limits rotary-compressor models to 100 ft of equivalent piping, with no exceptions. For the other tonnages, the maximum length is not published in the guide.
Is the YH5 LX cold-climate certified?
No: ENERGY STAR certifies it without the
Why choose the YH5 at 4 tons?
Because it is our only 4-ton YORK split central heat pump: the YH548, paired with the JHE48C5CG2SS1, certified at 47,000 BTU/h cooling and 30,400 BTU/h at −8.3 °C.
Is the YH5 loud?
YORK claims “as low as 69 dBA” in its technical guide, with no per-model level or test conditions. So we give no figure by tonnage.
Your YH5 LX, at the right tonnage, installed by AirGreen.
At the free visit, we size the tonnage, check the circuit (MCA 9.2 to 33.7 A) and the outdoor unit’s spot, and the quote gives the exact pairing.
Sources and dates checked
- YORK, Technical Guide
R-454B Outdoor Split-System Heat Pump YH5 (copy in our documents): features (p. 6), table 3 (p. 8) and table 4 (p. 9), read October 14 and re-read October 26, 2026. - ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, 5 YH5 records (IDs 3713095, 3627807, 4498100, 3627809, 3627810), Canadian market, re-read October 26, 2026.
- NEEP, Cold Climate Air Source Heat Pump List: no YH5 listed, searched by AHRI number on October 26 and 27, 2026.
Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile; participation guide v1.10 of September 15, 2026 (rates, p. 15), read October 14, 2026.- airgreen.ca product pages: matched systems we carry and AHRI numbers, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.