AirGreenYORK
YORK · R Series floor-ceiling YORK at AirGreenSold and installed by AirGreen in Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full YORK range
AirGreen × YORKSold and installed by AirGreenCeiling or low wall4-way discharge17 SEER at 30,000 BTU/h18,000 to 48,000 BTU/hMontreal · Laval · Longueuil · South Shore · North Shore
01 · Model by model

Six floor-ceiling units, 18,000 to 48,000 BTU/h, complete system.

Select a size: the indoor unit, the R Series outdoor unit that goes with it, and what the installation needs.

Size
DHR24NCB21S + DHR24CSB21SFloor-ceiling · 24,000 BTU/h · AHRI 8578441
See the product page →
Rated cooling
23,800 BTU/hrange 8,200 to 29,000
Heating at 8.3 °C
27,200 BTU/hrange 8,200 to 32,400
SEER · EER · HSPF
16 · 10.65 · 10
Heats
down to −18 °C
Indoor unit
dimensions confirmed in the quote88 lb · max. airflow 708 CFM
Indoor sound
49 → 40 dB(A)highest → lowest speed
Outdoor unit
39 × 31 × 17 in.152 lb · 57 dB(A)
Circuits (separate)
24 A · 40 Aoutdoor MCA · MOCP; indoor MCA 1 A
Liquid · vapour lines
3/8 · 5/8 in.1 in. drain
Max. length · lift
164 ft · 49.2 ft
Factory charge
77.6 oz

System SEER, EER and HSPF ratings under AHRI 210/240, heating rated at 8.3 °C (47 °F), as printed by YORK. Outdoor unit dimensions in inches: width × height × depth; net weights. The min. to max. ranges are those of the R Series outdoor unit in the 2020 catalogue. YORK’s brochure for this form gives a slightly different range at 18,000 BTU/h: we confirm the system’s range in the quote. YORK requires separate power for the indoor and outdoor units.

02 · Three forms, one outdoor unit

The floor-ceiling unit versus the cassette and ducted units.

On the same R Series outdoor unit, the indoor form changes efficiency, airflow and sound. Size for size:

Size
The three R Series forms at 24,000 BTU/h
ItemFloor-ceiling4-way cassetteDucted
SEER162016
EER10.6510.6510.65
HSPF101010
Rated heating at 8.3 °C27,200 BTU/h27,200 BTU/h27,200 BTU/h
Max. airflow708 CFM767 CFM826 CFM
Indoor sound at lowest40 dB(A)38 dB(A)40 dB(A)
Indoor unit weight88 lb60 lb75 lb

In green, the best value in the row. Same outdoor unit for all three forms. See also: 4-way cassette · Ducted.

AirGreen × YORK

YORK designs the unit; AirGreen picks its spot.

AirGreen looks at the walls, windows and ceiling with you, chooses the placement and size, then installs the indoor and outdoor units.

YORK

What YORK brings

  • Two placementsOn the ceiling or low on the wall, according to YORK.
  • 4-way dischargeAir leaves on all four sides; DRCR remote supplied.
  • 17 SEER at 30,000 BTU/hThe form’s best rating; 16 for the other sizes.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free visitWe measure the installation space, the electrical service, and the route for the refrigerant lines and the drain.
  • Clear quoteThe exact model, what is included and the price, in writing.
  • RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.

The result: a floor-ceiling unit mounted in the right spot for the room by AirGreen.

The YORK shop · Floor-ceiling

All 6 YORK floor-ceiling units, right below.

One listing per size, with the indoor unit, the outdoor unit and the AHRI number.

YORK
03 · Two placements

On the ceiling or low on the wall: one unit, two uses.

On the ceiling

Hung from the ceiling, the unit blows into the room: useful when the walls are taken by windows or furniture.

Placement 1
Low on the wall

“Mounted low on a wall”: YORK presents it as a good fit under a window, where a wall unit finds no room.

Placement 2
The same unit

According to YORK, the same unit hangs from the ceiling or mounts low on the wall; we confirm the placement and fixing in the quote.

Two placements
  • The indoor unit’s dimensions do not match between the catalogue’s inch and millimetre columns: we confirm them on YORK’s submittal before reserving the space.
  • Indoor unit weight: from 86 lb (18,000 BTU/h) to 130 lb (48,000 BTU/h); ceiling mounting is planned accordingly.
04 · Features

What YORK builds into the floor-ceiling unit.

4-way discharge

“4-way air discharge”, according to YORK.

Multi-speed fan

From 44 to 32 dB(A) at 18,000 BTU/h, highest to lowest speed.

DRCR remote

Supplied with the unit; DWCR or DWCR2 wired wall control as an option.

1 in. drain

1 in. drain connection; the catalogue mentions no built-in pump for this form.

05 · Before you choose

What to know about the floor-ceiling unit before you sign.

86 to 130 lbindoor unit weight by size: on the ceiling, the fixing is checked at the visit.
1 in.condensate drain; the catalogue lists no built-in pump for this form: we plan the drainage at the visit.
−18 °Climit of the R Series heating range (0 °F).
0/6AHRI numbers of our floor-ceiling units on the October 26, 2026 LogisVert list or at ENERGY STAR.
  • For a room that must heat lower with a visible unit, the Z Series wall unit goes down to −30 °C.
Frequently asked questions

What people ask us about the YORK floor-ceiling unit.

Ceiling or low on the wall: when is the placement chosen?

YORK presents the same unit hung from the ceiling or mounted low on the wall. We settle the placement with you before ordering.

Which size is the most efficient?

The 30,000 BTU/h, at 17 SEER; the five other sizes are rated 16.

Is it quiet?

From 44 to 32 dB(A) at 18,000 BTU/h and from 56 to 43 dB(A) at 48,000, highest to lowest speed, according to YORK.

What happens below −18 °C?

The unit leaves its published heating range (0 °F): the room needs backup heat, planned from the quote.

Does the R Series floor-ceiling unit qualify for LogisVert?

No: none of the 6 AHRI numbers on our listings is on Hydro-Québec’s October 26, 2026 list. So we promise no amount.

Sources and dates checked

  1. YORK, Mini-Split Systems catalogue PUBL-7782v6 (November 2020): R Series, outdoor unit (p. 17), cassette (p. 18), ducted (p. 19), floor-ceiling (p. 20), controls (pp. 40 to 43); copy in our documents, re-read October 26, 2026.
  2. YORK, R Series floor-ceiling unit brochure (copy in our documents): min. to max. ranges, read October 14, 2026.
  3. Hydro-Québec, LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.
  4. ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
  5. Environment and Climate Change Canada, 1981-2010 climate normals, Montréal–Trudeau (7025250), read October 14, 2026.
  6. airgreen.ca product pages: model and AHRI numbers of the systems we carry, read October 26, 2026.

Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.