Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
YORK X Series wall-mounted heat pump: our most efficient YORK wall unit on 115 V, from 9,000 to 24,000 BTU/h
On 115 V, the X is rated 23 SEER at 9,000 BTU/h and 22 SEER at 12,000, versus 16 for the P. On 208/230 V it goes up to 24,000 BTU/h, and its 9,000 reaches 14.29 EER. YORK builds it on a heavy-gauge steel frame with a corrosion-resistant coating.
The X versus the P, size by size, in SEER.
YORK 2020 catalogue, pp. 9 to 14; AHRI 210/240 ratings.
The six X Series models, on 115 V and 208/230 V.
Six models, two of them on 115 V. Select a size to see its full data, as printed in YORK’s catalogue, except the 12,000 BTU/h 208/230 V outdoor weight, inconsistent there.
- Rated cooling
- 9,000 BTU/hrange 2,764 to 10,918
- Heating at 8.3 °C
- 9,900 BTU/hrange 2,081 to 13,989
- SEER · EER · HSPF
- 23 · 13 · 10.5
- Heats
- down to −20 °C
- MCA · MOCP
- 12 A · 20 A
- Indoor unit
- 33 × 11 × 8 in.23 lb · max. airflow 400 CFM
- Outdoor unit
- 33 × 21 × 12.5 in.72 lb
- Indoor sound
- 43 → 26 dB(A)highest → lowest speed
- Outdoor sound
- 53 dB(A)
- Liquid · vapour lines
- 1/4 · 3/8 in.
- Max. length · lift
- 49.2 ft · 33 ft
- Factory charge
- 42.32 oz
- Rated cooling
- 12,000 BTU/hrange 3,514 to 14,569
- Heating at 8.3 °C
- 12,200 BTU/hrange 2,764 to 16,582
- SEER · EER · HSPF
- 22 · 12.5 · 10.2
- Heats
- down to −20 °C
- MCA · MOCP
- 15 A · 25 A
- Indoor unit
- 33 × 11 × 8 in.23 lb · max. airflow 400 CFM
- Outdoor unit
- 33 × 21 × 12.5 in.74 lb
- Indoor sound
- 45 → 28 dB(A)highest → lowest speed
- Outdoor sound
- 53 dB(A)
- Liquid · vapour lines
- 1/4 · 1/2 in.
- Max. length · lift
- 65.5 ft · 33 ft
- Factory charge
- 47.61 oz
- Rated cooling
- 9,000 BTU/hrange 3,099 to 9,599
- Heating at 8.3 °C
- 11,000 BTU/hrange 1,911 to 12,000
- SEER · EER · HSPF
- 23 · 14.29 · 10.5
- Heats
- down to −20 °C
- MCA · MOCP
- 9 A · 15 A
- Indoor unit
- 33 × 11 × 8 in.22 lb · max. airflow 318 CFM
- Outdoor unit
- 33 × 21 × 13 in.78 lb
- Indoor sound
- 43 → 29 dB(A)highest → lowest speed
- Outdoor sound
- 53 dB(A)
- Liquid · vapour lines
- 1/4 · 3/8 in.
- Max. length · lift
- 49.2 ft · 33 ft
- Factory charge
- 45.85 oz
- Rated cooling
- 12,000 BTU/hrange 3,099 to 12,999
- Heating at 8.3 °C
- 13,000 BTU/hrange 2,400 to 14,000
- SEER · EER · HSPF
- 22 · 12.5 · 10.1
- Heats
- down to −20 °C
- MCA · MOCP
- 9 A · 15 A
- Indoor unit
- 33 × 11 × 8 in.22 lb · max. airflow 400 CFM
- Outdoor unit
- 33 × 21 × 13 in.confirmed in the quote
- Indoor sound
- 45 → 29 dB(A)highest → lowest speed
- Outdoor sound
- 54 dB(A)
- Liquid · vapour lines
- 1/4 · 1/2 in.
- Max. length · lift
- 65.5 ft · 33 ft
- Factory charge
- 47.61 oz
- Rated cooling
- 18,000 BTU/hrange 7,165 to 20,000
- Heating at 8.3 °C
- 19,800 BTU/hrange 7,336 to 23,498
- SEER · EER · HSPF
- 20 · 12.5 · 10
- Heats
- down to −20 °C
- MCA · MOCP
- 16 A · 25 A
- Indoor unit
- 38 × 12 × 9 in.30 lb · max. airflow 559 CFM
- Outdoor unit
- 38 × 28 × 16 in.114 lb
- Indoor sound
- 47 → 35 dB(A)highest → lowest speed
- Outdoor sound
- 55 dB(A)
- Liquid · vapour lines
- 1/4 · 5/8 in.
- Max. length · lift
- 82 ft · 33 ft
- Factory charge
- 56.43 oz
- Rated cooling
- 22,000 BTU/hrange 6,824 to 27,296
- Heating at 8.3 °C
- 23,000 BTU/hrange 6,824 to 30,708
- SEER · EER · HSPF
- 20 · 12.5 · 10
- Heats
- down to −20 °C
- MCA · MOCP
- 20 A · 30 A
- Indoor unit
- 42 × 13 × 10 in.38 lb · max. airflow 706 CFM
- Outdoor unit
- 39 × 31 × 17 in.142 lb
- Indoor sound
- 48 → 36 dB(A)highest → lowest speed
- Outdoor sound
- 59 dB(A)
- Liquid · vapour lines
- 1/4 · 5/8 in.
- Max. length · lift
- 82 ft · 33 ft
- Factory charge
- 77.6 oz
SEER, EER and HSPF ratings under AHRI 210/240, heating rated at 8.3 °C (47 °F) outdoors, as printed by YORK in 2020. Dimensions in inches: width × height × depth; net weights.
The X between the P and the Z, in figures.
At each 208/230 V size, the X versus the P and, up to 18,000 BTU/h, versus the Z.
| Item | X Series | P Series | Difference vs P | Z Series | Difference vs Z |
|---|---|---|---|---|---|
| SEER | 23 | 16 | +7 | 28 | −5 |
| EER | 14.29 | 10 | +4.29 | 15 | −0.71 |
| HSPF | 10.5 | 9 | +1.5 | 10.5 | equal |
| Rated heating at 8.3 °C | 11,000 BTU/h | 9,500 BTU/h | +1,500 BTU/h | 9,000 BTU/h | +2,000 BTU/h |
| Max. heating at 8.3 °C | 12,000 BTU/h | 12,000 BTU/h | equal | 13,645 BTU/h | −1,645 BTU/h |
| Heats down to | −20 °C | −20 °C | equal | −30 °C | limit 10 °C higher |
| Indoor sound at lowest | 29 dB(A) | 28 dB(A) | +1 dB(A) | 22 dB(A) | +7 dB(A) |
| Outdoor sound | 53 dB(A) | 52 dB(A) | +1 dB(A) | 53 dB(A) | equal |
| Outdoor unit weight | 78 lb | 65 lb | +13 lb | 99 lb | −21 lb |
| Refrigerant vapour line | 3/8 in. | 3/8 in. | equal | 1/2 in. | different |
| Item | X Series | P Series | Difference vs P | Z Series | Difference vs Z |
|---|---|---|---|---|---|
| SEER | 22 | 16 | +6 | 23 | −1 |
| EER | 12.5 | 9.25 | +3.25 | 12.7 | −0.2 |
| HSPF | 10.1 | 9 | +1.1 | 10.5 | −0.4 |
| Rated heating at 8.3 °C | 13,000 BTU/h | 13,000 BTU/h | equal | 13,000 BTU/h | equal |
| Max. heating at 8.3 °C | 14,000 BTU/h | 14,000 BTU/h | equal | 18,766 BTU/h | −4,766 BTU/h |
| Heats down to | −20 °C | −20 °C | equal | −30 °C | limit 10 °C higher |
| Indoor sound at lowest | 29 dB(A) | 29 dB(A) | equal | 23 dB(A) | +6 dB(A) |
| Outdoor sound | 54 dB(A) | 53 dB(A) | +1 dB(A) | 55 dB(A) | −1 dB(A) |
| Outdoor unit weight | confirmed in the quote | 70 lb | — | 97 lb | — |
| Refrigerant vapour line | 1/2 in. | 3/8 in. | different | 1/2 in. | equal |
| Item | X Series | P Series | Difference vs P | Z Series | Difference vs Z |
|---|---|---|---|---|---|
| SEER | 20 | 16 | +4 | 21 | −1 |
| EER | 12.5 | 9 | +3.5 | 12.5 | equal |
| HSPF | 10 | 9 | +1 | 10.5 | −0.5 |
| Rated heating at 8.3 °C | 19,800 BTU/h | 19,000 BTU/h | +800 BTU/h | 19,000 BTU/h | +800 BTU/h |
| Max. heating at 8.3 °C | 23,498 BTU/h | 23,498 BTU/h | equal | 24,566 BTU/h | −1,068 BTU/h |
| Heats down to | −20 °C | −20 °C | equal | −30 °C | limit 10 °C higher |
| Indoor sound at lowest | 35 dB(A) | 35 dB(A) | equal | 26 dB(A) | +9 dB(A) |
| Outdoor sound | 55 dB(A) | 56 dB(A) | −1 dB(A) | 59 dB(A) | −4 dB(A) |
| Outdoor unit weight | 114 lb | 96 lb | +18 lb | 141 lb | −27 lb |
| Refrigerant vapour line | 5/8 in. | 1/2 in. | different | 5/8 in. | equal |
| Item | X Series | P Series | Difference vs P |
|---|---|---|---|
| SEER | 20 | 16 | +4 |
| EER | 12.5 | 9.75 | +2.75 |
| HSPF | 10 | 9 | +1 |
| Rated heating at 8.3 °C | 23,000 BTU/h | 23,000 BTU/h | equal |
| Max. heating at 8.3 °C | 30,708 BTU/h | 26,000 BTU/h | +4,708 BTU/h |
| Heats down to | −20 °C | −20 °C | equal |
| Indoor sound at lowest | 36 dB(A) | 36 dB(A) | equal |
| Outdoor sound | 59 dB(A) | 59 dB(A) | equal |
| Outdoor unit weight | 142 lb | confirmed in the quote | — |
| Refrigerant vapour line | 5/8 in. | 5/8 in. | equal |
The difference reads “X Series minus the other series”; in green, the X’s advantage, in brown, the other series’. The three-series comparison is on the YORK wall units page.
The X Series, designed by YORK, installed by AirGreen.
AirGreen picks the size and voltage with you, checks the circuit and installs both units.
What YORK brings
- 22 to 23 SEER on 115 VAt 9,000 and 12,000 BTU/h.
- Sturdy buildHeavy-gauge steel frame and corrosion-resistant coating, according to YORK.
- Defrost as neededOnly when needed, according to YORK.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the insulation, the electrical service and the refrigerant line route.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: an X Series at the right size and voltage, installed by AirGreen.
All 6 X Series units, right below.
One listing per model, with its indoor and outdoor model numbers and its AHRI number.
What YORK builds into the X.
A feature YORK lists only for the X among its wall units.
Per YORK’s X Series features.
According to YORK, the X defrosts only when needed.
From 43 to 48 dB(A) at the highest speed, 26 to 36 dB(A) at the lowest, depending on the model.
DRCPX remote supplied; CS532AH adapter for the EWPE Smart app.
The 208/230 V X indoor units also serve as wall heads on YORK’s W Series
On 115 V, our most efficient YORK wall unit.
Two sizes, 9,000 and 12,000 BTU/h, in both voltages: what moving to 115 V changes.
| Size | SEER (115 V · 230 V) | Heating at 8.3 °C (115 V · 230 V) | MCA / MOCP (115 V · 230 V) | Outdoor unit (115 V · 230 V) |
|---|---|---|---|---|
| 9,000 BTU/h | 23 · 23 | 9,900 · 11,000 BTU/h | 12 / 20 A · 9 / 15 A | 33 × 21 × 12.5 · 33 × 21 × 13 in. |
| 12,000 BTU/h | 22 · 22 | 12,200 · 13,000 BTU/h | 15 / 25 A · 9 / 15 A | 33 × 21 × 12.5 · 33 × 21 × 13 in. |
- On 115 V the X keeps 23 SEER at 9,000 BTU/h and 22 SEER at 12,000 BTU/h, as on 208/230 V; the P on 115 V is rated 16.
- The circuit changes: 12 A / 20 A and 15 A / 25 A (MCA / MOCP) on 115 V, versus 9 A / 15 A on 208/230 V.
What people ask us about the X Series.
Why choose the X on 115 V?
Because it is rated 23 SEER (9,000 BTU/h) and 22 SEER (12,000 BTU/h) there, versus 16 for the P Series at the same voltage. The required circuit is 12 A or 15 A (MCA).
What is the largest X?
The DHX24: 22,000 BTU/h of cooling and 23,000 BTU/h of rated heating, 20 SEER, with a 39 × 31 × 17 in., 142 lb outdoor unit.
How cold does the X heat?
Down to −20 °C (−4 °F), like the P Series. Only the Z Series goes down to −30 °C.
Does the X Series qualify for LogisVert?
Not our listings: none of the 6 AHRI numbers on our X Series listings is on
X or Z at 12,000 BTU/h?
Same rated heating (13,000 BTU/h). The Z is rated 23 SEER versus 22, goes down to 23 dB(A) versus 29 and heats down to −30 °C versus −20 °C; the X also comes in 115 V.
Your X Series, on 115 V or 208/230 V, installed by AirGreen.
At the free visit, we choose the size, look at your electrical panel for the voltage, and check the line-set route.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): P, X and Z Series (pp. 9 to 16), features (p. 8), controls and accessories (pp. 40 to 44), listing and warranty (pp. 3 and 4); copy in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- ENERGY STAR, Certified Air-Source Heat Pumps, dataset w7cv-9xjt, searched by AHRI number on October 26, 2026.
- airgreen.ca product pages: model and AHRI numbers of the units we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.