YORK P Series wall-mounted heat pump: 9,000 to 36,000 BTU/h, the only one in our catalogue above 24,000
The P Series runs from 9,000 to 36,000 BTU/h and comes in 115 V at 9,000 and 12,000. It is rated 16 SEER up to 24,000 BTU/h and 18 SEER at 30,000 and 36,000, and heats down to −20 °C.
Eight models, from 9,500 to 34,600 BTU/h of heating.
YORK 2020 catalogue, pp. 9 to 11.
The eight P Series models, from the 9,000 BTU/h on 115 V to the 36,000.
Eight models, two on 115 V. Select a size: everything YORK’s catalogue prints for that model, except the two 24,000 BTU/h values that contradict each other there.
- Rated cooling
- 9,000 BTU/hrange 2,764 to 10,918
- Heating at 8.3 °C
- 9,600 BTU/hrange 2,081 to 12,283
- SEER · EER · HSPF
- 16 · 9.55 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 17 A · 25 A
- Indoor unit
- 31 × 11 × 8 in.20 lb · max. airflow 318 CFM
- Outdoor unit
- 33 × 21 × 12.5 in.63 lb
- Indoor sound
- 42 → 28 dB(A)highest → lowest speed
- Outdoor sound
- 53 dB(A)
- Liquid · vapour lines
- 1/4 · 3/8 in.
- Max. length · lift
- 49.2 ft · 33 ft
- Factory charge
- 24.69 oz
- Rated cooling
- 12,000 BTU/hrange 3,753 to 12,500
- Heating at 8.3 °C
- 13,000 BTU/hrange 3,412 to 15,013
- SEER · EER · HSPF
- 16 · 10.55 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 20 A · 30 A
- Indoor unit
- 33 × 11 × 8 in.22 lb · max. airflow 400 CFM
- Outdoor unit
- 33 × 21 × 12.5 in.67 lb
- Indoor sound
- 43 → 29 dB(A)highest → lowest speed
- Outdoor sound
- 53 dB(A)
- Liquid · vapour lines
- 1/4 · 3/8 in.
- Max. length · lift
- 65 ft · 33 ft
- Factory charge
- 31.74 oz
- Rated cooling
- 9,000 BTU/hrange 3,100 to 9,600
- Heating at 8.3 °C
- 9,500 BTU/hrange 3,100 to 12,000
- SEER · EER · HSPF
- 16 · 10 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 9 A · 15 A
- Indoor unit
- 31 × 11 × 8 in.20 lb · max. airflow 318 CFM
- Outdoor unit
- 30.5 × 21 × 12.5 in.65 lb
- Indoor sound
- 42 → 28 dB(A)highest → lowest speed
- Outdoor sound
- 52 dB(A)
- Liquid · vapour lines
- 1/4 · 3/8 in.
- Max. length · lift
- 49.2 ft · 33 ft
- Factory charge
- 24.69 oz
- Rated cooling
- 12,000 BTU/hrange 3,753 to 12,500
- Heating at 8.3 °C
- 13,000 BTU/hrange 3,924 to 14,000
- SEER · EER · HSPF
- 16 · 9.25 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 9 A · 15 A
- Indoor unit
- 33 × 11 × 8 in.22 lb · max. airflow 400 CFM
- Outdoor unit
- 30.5 × 21 × 12.5 in.70 lb
- Indoor sound
- 43 → 29 dB(A)highest → lowest speed
- Outdoor sound
- 53 dB(A)
- Liquid · vapour lines
- 1/4 · 3/8 in.
- Max. length · lift
- 65 ft · 33 ft
- Factory charge
- 29.98 oz
- Rated cooling
- 18,000 BTU/hrange 7,165 to 20,000
- Heating at 8.3 °C
- 19,000 BTU/hrange 7,336 to 23,498
- SEER · EER · HSPF
- 16 · 9 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 16 A · 25 A
- Indoor unit
- 38 × 12 × 9 in.30 lb · max. airflow 471 CFM
- Outdoor unit
- 38 × 28 × 16 in.96 lb
- Indoor sound
- 46 → 35 dB(A)highest → lowest speed
- Outdoor sound
- 56 dB(A)
- Liquid · vapour lines
- 1/4 · 1/2 in.
- Max. length · lift
- 82 ft · 33 ft
- Factory charge
- 49.38 oz
- Rated cooling
- 22,000 BTU/hrange 8,630 to 23,200
- Heating at 8.3 °C
- 23,000 BTU/hrange 8,650 to 26,000
- SEER · EER · HSPF
- 16 · 9.75 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 16 A · 25 A
- Indoor unit
- 42 × 13 × 10 in.38 lb · max. airflow 706 CFM
- Outdoor unit
- 38 × 28 × 16 in.confirmed in the quote
- Indoor sound
- 48 → 36 dB(A)highest → lowest speed
- Outdoor sound
- 59 dB(A)
- Liquid · vapour lines
- 1/4 · 5/8 in.
- Max. length · lift
- 82 ft · 33 ft
- Factory charge
- confirmed in the quote
- Rated cooling
- 28,000 BTU/hrange 9,485 to 30,025
- Heating at 8.3 °C
- 28,400 BTU/hrange 9,997 to 32,994
- SEER · EER · HSPF
- 18 · 10.35 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 20 A · 30 A
- Indoor unit
- 53 × 13 × 10 in.42 lb · max. airflow 706 CFM
- Outdoor unit
- 39 × 31 × 17 in.154 lb
- Indoor sound
- 51 → 37 dB(A)highest → lowest speed
- Outdoor sound
- 62 dB(A)
- Liquid · vapour lines
- 1/4 · 5/8 in.
- Max. length · lift
- 98.5 ft · 33 ft
- Factory charge
- 84.65 oz
- Rated cooling
- 33,600 BTU/hrange 7,404 to 35,997
- Heating at 8.3 °C
- 34,600 BTU/hrange 14,979 to 35,997
- SEER · EER · HSPF
- 18 · 8.2 · 9
- Heats
- down to −20 °C
- MCA · MOCP
- 24 A · 40 A
- Indoor unit
- 53 × 13 × 10 in.42 lb · max. airflow 736 CFM
- Outdoor unit
- 39 × 31 × 17 in.154 lb
- Indoor sound
- 54 → 37 dB(A)highest → lowest speed
- Outdoor sound
- 65 dB(A)
- Liquid · vapour lines
- 1/4 · 5/8 in.
- Max. length · lift
- 98.5 ft · 33 ft
- Factory charge
- 91.71 oz
SEER, EER and HSPF ratings under AHRI 210/240, heating rated at 8.3 °C (47 °F) outdoors, as printed by YORK in 2020. Dimensions in inches: width × height × depth; net weights.
What the P gives up to the X, size for size.
At 9,000, 12,000, 18,000 and 24,000 BTU/h on 208/230 V, the P versus the X: efficiency, heating, sound and weight.
| Item | P Series | X Series | Difference vs X |
|---|---|---|---|
| SEER | 16 | 23 | −7 |
| EER | 10 | 14.29 | −4.29 |
| HSPF | 9 | 10.5 | −1.5 |
| Rated heating at 8.3 °C | 9,500 BTU/h | 11,000 BTU/h | −1,500 BTU/h |
| Max. heating at 8.3 °C | 12,000 BTU/h | 12,000 BTU/h | equal |
| Heats down to | −20 °C | −20 °C | equal |
| Indoor sound at lowest | 28 dB(A) | 29 dB(A) | −1 dB(A) |
| Outdoor sound | 52 dB(A) | 53 dB(A) | −1 dB(A) |
| Outdoor unit weight | 65 lb | 78 lb | −13 lb |
| Refrigerant vapour line | 3/8 in. | 3/8 in. | equal |
| Item | P Series | X Series | Difference vs X |
|---|---|---|---|
| SEER | 16 | 22 | −6 |
| EER | 9.25 | 12.5 | −3.25 |
| HSPF | 9 | 10.1 | −1.1 |
| Rated heating at 8.3 °C | 13,000 BTU/h | 13,000 BTU/h | equal |
| Max. heating at 8.3 °C | 14,000 BTU/h | 14,000 BTU/h | equal |
| Heats down to | −20 °C | −20 °C | equal |
| Indoor sound at lowest | 29 dB(A) | 29 dB(A) | equal |
| Outdoor sound | 53 dB(A) | 54 dB(A) | −1 dB(A) |
| Outdoor unit weight | 70 lb | confirmed in the quote | — |
| Refrigerant vapour line | 3/8 in. | 1/2 in. | different |
| Item | P Series | X Series | Difference vs X |
|---|---|---|---|
| SEER | 16 | 20 | −4 |
| EER | 9 | 12.5 | −3.5 |
| HSPF | 9 | 10 | −1 |
| Rated heating at 8.3 °C | 19,000 BTU/h | 19,800 BTU/h | −800 BTU/h |
| Max. heating at 8.3 °C | 23,498 BTU/h | 23,498 BTU/h | equal |
| Heats down to | −20 °C | −20 °C | equal |
| Indoor sound at lowest | 35 dB(A) | 35 dB(A) | equal |
| Outdoor sound | 56 dB(A) | 55 dB(A) | +1 dB(A) |
| Outdoor unit weight | 96 lb | 114 lb | −18 lb |
| Refrigerant vapour line | 1/2 in. | 5/8 in. | different |
| Item | P Series | X Series | Difference vs X |
|---|---|---|---|
| SEER | 16 | 20 | −4 |
| EER | 9.75 | 12.5 | −2.75 |
| HSPF | 9 | 10 | −1 |
| Rated heating at 8.3 °C | 23,000 BTU/h | 23,000 BTU/h | equal |
| Max. heating at 8.3 °C | 26,000 BTU/h | 30,708 BTU/h | −4,708 BTU/h |
| Heats down to | −20 °C | −20 °C | equal |
| Indoor sound at lowest | 36 dB(A) | 36 dB(A) | equal |
| Outdoor sound | 59 dB(A) | 59 dB(A) | equal |
| Outdoor unit weight | confirmed in the quote | 142 lb | — |
| Refrigerant vapour line | 5/8 in. | 5/8 in. | equal |
The difference reads “P Series minus the other series”; in green, the P’s advantage, in brown, the other series’. The three-series comparison is on the YORK wall units page.
The P Series, designed by YORK, installed by AirGreen.
AirGreen picks the size with you, from a bedroom’s 9,000 BTU/h to a large open area’s 36,000, and installs both units.
What YORK brings
- Eight models, two voltagesFrom 9,000 to 36,000 BTU/h; 115 V at 9,000 and 12,000 BTU/h.
- Cooling in cold weather down to −18 °C“Low ambient cooling to 0° F” according to YORK.
- Optional
Wi-Fi CS532AH adapter and EWPE Smart app.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe measure the rooms, the insulation, the electrical service and the refrigerant line route.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: a P Series sized for the room, installed by AirGreen.
All 8 P Series units, right below.
One listing per model, with its indoor and outdoor model numbers and its AHRI number.
30,000 and 36,000 BTU/h: where only the P goes.
YORK’s two largest wall units, for a large open area, and what they need at installation.
- Circuit: MCA 20 A and MOCP 30 A for the DHP30; 24 A and 40 A for the DHP36, the largest circuit among YORK wall units.
- Cooling: the DHP36 runs up to 43 °C (109 °F) outdoors, the other P models up to 46 °C (115 °F).
- Sound: 62 and 65 dB(A) outdoors; 51 to 37 dB(A) (DHP30) and 54 to 37 dB(A) (DHP36) indoors.
What the P does, according to YORK.
YORK also offers the P as cooling only (DCP models); the eight listings on this page are heat pumps (DHP).
“Low ambient cooling to 0° F”: the P keeps cooling at outdoor temperatures down to −18 °C, for example in an equipment room that runs warm all year.
The louver sweeps up and down to spread the air, per YORK’s P Series features.
The room temperature shows on the indoor unit.
Supplied with the unit; DWCPX2 or DWUNI wired wall control as an option.
With the CS532AH adapter, the P runs from the EWPE Smart app.
The 9,000 to 24,000 BTU/h P indoor units also serve as wall heads on YORK’s M Series
What people ask us about the P Series.
Does the P Series come in 115 V?
Yes, at 9,000 and 12,000 BTU/h (DHP09 and DHP12 “11S”). The required circuit is 17 A and 20 A (MCA); we check it at the visit.
What is the largest YORK wall unit?
The P Series DHP36: 33,600 BTU/h of cooling and 34,600 BTU/h of rated heating at 8.3 °C. Together with the DHP30, they are the only two YORK wall units in our catalogue above 24,000 BTU/h.
How cold does the P heat?
Down to −20 °C (−4 °F), per the range YORK publishes, for all eight models. For colder, the Z Series goes to −30 °C.
P or X at 24,000 BTU/h?
Same rated capacities (22,000 BTU/h cooling, 23,000 heating) and the same 42 × 13 × 10 in. indoor cabinet. The X is rated 20 SEER and 12.5 EER, the P 16 and 9.75.
Does the P Series qualify for LogisVert?
No: none of the 8 AHRI numbers on our P Series listings is on
Your P Series, sized for the room and installed by AirGreen.
At the free visit, we choose the size and voltage, and check the circuit (9 A to 24 A depending on the model) and the line-set route.
Sources and dates checked
- YORK, Mini-Split Systems catalogue
PUBL-7782v6 (November 2020): P, X and Z Series (pp. 9 to 16), features (p. 8), controls and accessories (pp. 40 to 44), listing and warranty (pp. 3 and 4); copy in our documents, re-read October 26, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by AHRI number.- airgreen.ca product pages: model and AHRI numbers of the units we carry, read October 26, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.