AirGreenZEPHYR
ZEPHYRWall air conditioner · R-410AZEPHYR wall air conditioners at AirGreenSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The whole ZEPHYR space
AirGreen × ZEPHYRZephyr wall ACR-410AOn quoteSold and installed by AirGreenMontreal · Laval · Longueuil · South Shore · North Shore
01 · The sizes

3 Zephyr wall AC models, on quote.

Each card shows the 2023 brochure SEER, the silent-mode sound and the outdoor unit weight.

Did you know?
49 dB(A)outdoor unit (12,000)

The 12,000 AC is the quietest outside: 49 dB(A) at the outdoor unit, against 56 and 58 for the 18,000 and 24,000.Source: TTI “ZEPHYR 18” brochure (2023).

02 · Spec sheet

Every Zephyr wall AC figure, as printed.

Capacities, efficiency, sound, electrical, line sets, dimensions and weight, per TTI’s 2023 brochure.

ModelZE-12BA1712,000 BTU/hZE-18AA1718,000 BTU/hZE-24AA1724,000 BTU/h
Capacities (BTU/h)
Cooling12,00018,00024,000
Efficiency (old method, 2023 brochure)
SEER1718.317.2
EER10.910.510.4
Sound and air
Indoor (dB(A))40/36/33/2645/43/38/3548/45/40/36
Outdoor49 dB(A)56 dB(A)58 dB(A)
Airflow (cfm)365589677
Electrical and installation
Rated current (range), A9.8 (2.5–15)7.6 (1.8–12)10.5 (2.0–13)
Compressor / meteringRotary GMCC/Toshiba, capillaryRotary GMCC/Toshiba, capillaryRotary GMCC/Toshiba, capillary
Liquid / gas lines (in)1/4 / 3/81/4 / 1/23/8 / 5/8
Dimensions (as printed, in) and weight
Indoor unit33 1/2 × 10 5/8 × 8 1/437 13/16 × 12 7/16 × 9 1/1644 9/16 × 12 7/16 × 9 1/16
Outdoor unit28 3/16 × 19 × 9 1/231 15/16 × 23 1/16 × 11 1/16—
Net weight in. / out.9 / 26.5 kg12.5 / 38 kg14.5 / 48 kg
Programs
LogisVertNot eligibleNot eligibleNot eligible

Swipe the table.

Source: TTI “ZEPHYR 18” brochure printed in 2023, which also covers these air conditioners. LogisVert: guide v1.10.

Did you know?
2023brochure year

These figures come from a TTI brochure printed in 2023, hosted on airgreen.ca. TTI no longer publishes it on its site: we confirm every figure on the quote.Source: TTI, “ZEPHYR 18” and “Zephyr 23” brochures (R-410A, printed 2023), copies hosted on airgreen.ca, checked Oct. 8, 2026.

03 · SEER / SEER2

Why we do not compare SEER with SEER2.

The 2023 brochure gives SEER values, measured with the old method. Current series are rated in SEER2 and HSPF2. The calculator applies the same definition to the 2023 SEER values: heat removed over the season divided by the electricity used.

Two methods, two scales
ZE-18AA17 (2023 brochure)18.3 SEER
ZE-18CB25 (BRO_2606 brochure)21 SEER2

These two figures do not compare directly: SEER2 comes from a tougher test, with higher external static pressure (US DOE, Appendix M1, mandatory since January 1, 2023). In Canada, minimums are stated in SEER2 and HSPF2 since the same date.

Heat removed from the home over the summer (example)
3,000,000 BTU
ZE-12BA17 17 SEER176 kWh$19.61
ZE-18AA17 18.3 SEER164 kWh$18.27
ZE-24AA17 17.2 SEER174 kWh$19.39

Illustrative math: SEER (old method, DOE, Appendix M), like SEER2, is the heat removed over the season divided by the electricity used, in BTU per watt-hour. A SEER and a SEER2 do not compare directly. Cost at Hydro-Québec’s Rate D second-tier price (11.142¢/kWh since April 1, 2026), which applies if use exceeds the first tier (40 kWh per day, times the number of days in the period); below it, a kWh costs 7.065¢. Before taxes and access fees. Your home will have its own numbers.

Did you know?
14.3minimum SEER2 (heat pump)

Since January 1, 2023, a split heat pump made for Canada must reach at least 14.3 SEER2 and 6.0 HSPF2 (Region V); a split air conditioner, 13.4 SEER2.Source: SOR/2022-265, Canada Gazette, Part II, Dec. 21, 2022.

04 · LogisVert

Zephyr wall AC: no LogisVert. Here is why.

Hydro-Québec’s program follows simple rules, and the 2023 R-410A models do not fit them. Several current wall units, on the other hand, qualify by AHRI number.

Why no LogisVert
  • For cooling, LogisVert only funds air-to-air heat pumps “for heating and cooling”. A cooling-only unit is not a program measure.
  • A heat pump must also be ENERGY STAR certified (since November 26, 2025) and have an outdoor unit of at least 12,000 BTU/h.
With a current wall unit, same size
CB25 24,000$2,640
CB25 18,000$2,160
UB32 12,000$1,560
CB25 12,000$1,296
CB22 18,000$740

Amounts checked by AHRI number in Hydro-Québec’s tool (Oct. 6, 2026). Scale: $0 to $2,640.

Did you know?
26 Nov. 2025ENERGY STAR required

Since November 26, 2025, LogisVert requires a heat pump to be ENERGY STAR certified to qualify.Source: Hydro-Québec, residential LogisVert participation guide, version 1.10, Sept. 15, 2026 (2026G448F), and eligible heat pump search tool, checked Oct. 6, 2026.

05 · Sound and size

How many decibels, how many kilograms?

Pick a size: the bars show the sound pressure at each speed, then the dimensions and weight printed on the brochure.

Sound pressure, dB(A)
High40 dB(A)
Medium36 dB(A)
Low33 dB(A)
Silent26 dB(A)
Outdoor49 dB(A)

Scale: 0 to 60 dB(A). 2023 brochure values.

Dimensions and weight
Indoor (as printed, in)33 1/2 × 10 5/8 × 8 1/4
Outdoor (as printed, in)28 3/16 × 19 × 9 1/2
Net weight in. / out.9 / 26.5 kg

Dimensions shown in the order printed on the 2023 brochure.

Did you know?
48 kgoutdoor unit (24,000)

The 24,000 AC outdoor unit weighs 48 kg; the 12,000’s, 26.5 kg.Source: TTI “ZEPHYR 18” brochure (2023).

06 · Electricity

How many watts at rated capacity?

The brochure ratings are enough to estimate the power drawn at test conditions. Pick a size: the meter follows.

Pick a size
Capacity (brochure)12,000 BTU/h
Rating (brochure)EER 10.9
Rated current (brochure)9.8 A
Math12,000 BTU/h ÷ 10.9 EER
Cooling · ZE-12BA17
1,101 W
Power draw1,101 W

Scale: 0 to 2,500 W. At the brochure’s test conditions, not in deep cold.

AirGreen math from the ratings printed in 2023: EER is cooling in BTU/h per watt used. The rated current is the brochure’s; a variable-speed unit can draw more or less depending on the load.

Did you know?
2,308 Wcooling (24,000)

At rated capacity (test conditions), the 24,000 AC draws about 2,308 W: 24,000 BTU/h ÷ 10.4 EER, per the 2023 brochure ratings.Source: TTI “ZEPHYR 18” brochure (2023); AirGreen math.

07 · Refrigerant

R-410A, still allowed in Canada.

These Zephyr ACs use R-410A, an A1 (non-flammable) refrigerant with a GWP of 2,090. Current series moved to R-454B (CB25, UB32) and R-32 (CB22).

Global warming potential (GWP)
R-410AA12,090
R-32A2L675
R-454BA2L470

GWP and ASHRAE class per the EPA (SNAP, March 19, 2026). A1: non-flammable.

What R-410A is made of
50% R-3250% R-125

Composition per ASHRAE designations (410A: R-32/125, 50.0/50.0).

In Canada, no GWP limit applies to residential air conditioners and heat pumps: R-410A remains allowed (SOR/2016-137, Schedule 1.1, current to Apr. 28, 2026). In the United States, new residential equipment installed since January 1, 2025 must use a refrigerant with a GWP under 700, unless its components were made or imported before 2025; on May 21, 2026, the EPA removed the January 1, 2026 installation deadline for those components.
Did you know?
50/50R-32 / R-125

R-410A is an equal blend of R-32 and R-125. R-32 alone is the CB22’s refrigerant.Source: ASHRAE refrigerant designations.

08 · Features

The features printed in 2023.

The feature list from TTI’s 2023 brochure. Filter by use.

Cooling only
“I feel”
Auto restart
Auto cleaning
7 indoor fan speeds
Features from the 2023 “ZEPHYR 18” brochure, which also covers these air conditioners; we kept only those unrelated to heating.
Did you know?
7fan speeds

The Zephyr wall AC has 7 indoor fan speeds, per the 2023 brochure.Source: TTI “ZEPHYR 18” brochure (2023).

09 · The current series

What replaces the Zephyr wall AC today, size for size.

Current Zephyr wall units use R-454B or R-32, most of them ENERGY STAR certified; every series has models that qualify for LogisVert (12,000 BTU/h and up, depending on the model). They also heat, which an air conditioner does not.

Same nominal size and voltage
ZE-12BA172023 · R-410A · 115 V (our page)CB25R-454B · ZE-12DB25CB22R-32 · ZE-12DB22
Refrigerant (GWP)R-410A (2,090)R-454B (470)R-32 (675)
HeatingNo (cooling only)Down to -30 °CDown to -25 °C
Efficiency17 SEER (old)22 SEER220 SEER2
Silent (indoor)26 dB(A)32 dB(A)28 dB(A)
Outdoor unit49 dB(A)53 dB(A)52 dB(A)
ENERGY STARN/A (cooling only)Cold climateNot listed
LogisVertNot eligible$1,116Not eligible (not ENERGY STAR)
Product pageSeeSeeSee

Swipe the table.

Framed column: the 2023 unit. Sources: 2023 TTI brochure, BRO_2606 brochures, ENERGY STAR (Oct. 8, 2026), LogisVert tool (Oct. 6, 2026). A SEER (old method) and a SEER2 do not compare directly. In green: what changes the most.

Did you know?
-30 °CCB25 and UB32

The CB25 and UB32 run in heating mode down to -30 °C per Zephyr, and cool from -15 to 48 °C.Source: BRO_2606 brochures.

10 · Timeline

R-410A, from 2023 to today.

Swipe left to right. In red: Zephyr; in green: rules.

  1. ZEPHYR 18 brochure

    TTI prints the brochure for this R-410A generation.

    Zephyr
  2. SEER2 / HSPF2

    New test method mandatory (DOE Appendix M1); Canadian minimums in SEER2.

    Rule
  3. CB22 and CB25

    The R-32 and R-454B wall units reach the market.

    Zephyr
  4. US: GWP under 700

    New residential equipment installed, except components made or imported before 2025.

    Rule
  5. LogisVert requires ENERGY STAR

    Models not on the list no longer qualify.

    Rule
  6. EPA: deadline removed

    Equipment made before 2025 can still be installed in the US.

    Rule
  7. 6-year legal warranty

    For air conditioners and heat pumps bought new from that date (OPC).

    Rule
Did you know?
2,090R-410A GWP

R-410A’s GWP is 2,090 per the EPA (ENERGY STAR shows 2,088 in its records): more than 4 times R-454B’s (470).Source: EPA SNAP (March 19, 2026); ENERGY STAR.

AirGreen × ZEPHYR

ZEPHYR and AirGreen, for the R-410A generation too.

We tell you plainly what the Zephyr wall AC offers, what it does not, and what a current unit would change.

ZEPHYR

What ZEPHYR brings

  • Zephyr wall ACA Zephyr R-410A unit, documented by TTI in 2023.
  • On quoteAvailability confirmed with TTI.
  • R-410AStill allowed in Canada.
  • Current seriesCB22, CB25 and UB32, if you want LogisVert.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenMontreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free home estimateWe look at the rooms, where the units go and the line set route.
  • Warranty registered for youWith TTI, free of charge: serial numbers, date, photos.
  • RBQ 5645-9605-01Subclasses 15.8 (ventilation), 15.10 (refrigeration) and 16 (electrical).

The result: the right unit for the room, installed by AirGreen, with a clear quote.

11 · Warranty and installation

What the brochure said, and what the law says.

The 2023 brochure announced 10 years on parts and compressor. For a unit bought new on or after October 5, 2026, the law adds a 6-year warranty of good working order, counted from delivery.

Zephyr base warranty
10 years

on parts and compressor, per the 2023 ZEPHYR 18 brochure. We confirm the warranty on the quote.

Parts (Zephyr)
10 years
Legal warranty
6 years

For a heat pump or air conditioner bought new from a merchant on or after October 5, 2026, Quebec law adds a free, automatic 6-year warranty of good working order, counted from delivery (Office de la protection du consommateur). Under TTI’s parts policy (v3.4, July 17, 2026), labour to replace a part during that period falls on the installing contractor.

Certified technician

Service or repair by anyone not certified and authorized by TTI (or Kinghome) ends the manufacturer’s conventional warranty (TTI, s. 4.4).

Through your installer

If something breaks, you call the contractor who installed it; they file the claim with TTI.

Filters, every month

TTI’s policy asks owners to clean the indoor unit filters at least once a month (s. 6.3).

1Free visit

We look at the rooms, where the units go and the line set route.

2Clear quote

The exact model, the AHRI number, the indicative LogisVert amount when it applies.

3Installation and start-up

Vacuum, refrigerant charge, cooling tests.

4Warranty registered

We register the units with TTI for you: nameplate, serial numbers, invoice.

12 · Our projects

Our Zephyr installations.

Each blog post shows one installation: the unit, the place, how it was done.

13 · Frequently asked questions

What people ask us about Zephyr wall ACs.

An air conditioner only cools. A wall heat pump cools and heats: the CB25, for example, cools from -15 to 48 °C and heats down to -30 °C per Zephyr, and may qualify for LogisVert.

AirGreen × ZEPHYRZephyr wall ACR-410AOn quoteSold and installed by AirGreenMontreal · Laval · Longueuil · South Shore · North Shore

Sources checked October 6 to 9, 2026

  1. TTI, “ZEPHYR 18” and “Zephyr 23” brochures (R-410A, printed 2023), copies hosted on airgreen.ca, checked Oct. 8, 2026.
  2. TTI Climatisation Chauffage, Zephyr CB22, CB25 and UB32 brochures (code BRO_2606), tticlimatisation.com/manuels, checked Oct. 8, 2026: capacities from -8.3 to -25 °C, COP, SEER2, HSPF2, sound, dimensions, line sets, electrical, features, warranty.
  3. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt, updated Oct. 8, 2026), checked Oct. 8, 2026: SEER2, EER2, HSPF2, capacities at 47, 17 and 5 °F, COP at 5 °F, cold-climate status, market date, by AHRI number.
  4. Hydro-Québec, residential LogisVert participation guide, version 1.10, Sept. 15, 2026 (2026G448F), and eligible heat pump search tool, checked Oct. 6, 2026.
  5. Energy Efficiency Regulations, 2016, Amendment 17, SOR/2022-265, Canada Gazette, Part II, Dec. 21, 2022 (SEER2, HSPF2 Region V, -15 °C test from 2025).
  6. US DOE, 10 CFR 430, Subpart B, Appendices M and M1 (SEER, HSPF, COP definitions); DOE Energy Saver, “Electric Resistance Heating”.
  7. US EPA, SNAP, “Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps”, updated March 19, 2026 (GWP and ASHRAE classes); ASHRAE refrigerant designations (R-454B = R-32/R-1234yf 68.9/31.1) and Addendum g to Standard 34-2016 (class 2L).
  8. US eCFR, 40 CFR 84.54 (current to Oct. 5, 2026) and EPA fact sheet of May 21, 2026 on the Technology Transitions rule.
  9. Ozone-depleting Substances and Halocarbon Alternatives Regulations (SOR/2016-137), Schedule 1.1, current to Apr. 28, 2026.
  10. TTI, parts availability policy, version 3.4, July 17, 2026 (ss. 4.3, 4.4 and 6.3: labour during the legal warranty, certified and authorized technician, filter cleaning).
  11. AirGreen: airgreen.ca product pages and “Nos réalisations” blog, as of Oct. 8, 2026.
  12. Office de la protection du consommateur, warranty of good working order (opc.gouv.qc.ca) and legal warranty notice, checked Oct. 9, 2026; Order in Council 1459-2025, Gazette officielle du Québec (s. 79.21 of the regulation under the Consumer Protection Act, in force Oct. 5, 2026): air conditioner and heat pump, 6 years.
  13. Hydro-Québec, residential LogisVert program page and fraud prevention page (hydroquebec.com), checked Oct. 9, 2026: no telephone or door-to-door solicitation for LogisVert.

The R-410A generation data come from a 2023 brochure: we confirm them on the quote.

Prices on quote. Free home estimate.
The Zephyr wall AC shop

Zephyr wall ACs, right below.

Price and availability on quote. Free home estimate.

ZEPHYR