AirGreen × TOSOT · Sold and installed by AirGreenTOSOT ducted units at AirGreenLow or high static, from 9,000 to 24,000 BTU/h, on a multi-zone compressor.
TOSOT ducted units: low or high static, the difference in figures
Eight ducted units. The four low-static models are 7.9 in. high; the four high-static models are 11 13/16 in. and push air up to 0.6 or 0.8 in. WC through the ducts. Pick a size, see what changes.
0.8 in. WCmaximum pressure, high static 18,000 and 24,000
7.9 in.high, low static
8pressure settings, high static
01 · Static pressure
Pick the static pressure and the size
Both TOSOT ducted families, size by size: the height to plan for, the pressure available for the ducts, airflow and sound.
Static pressure
Size · BTU/h
TM12HFD-I: 7.9 in. high, 50.7 lb net, 324 CFM at most per the TOSOT leaflet.
12,000 BTU/h · low staticTM12HFD-I
Side view, to scale. Solid: the static pressure you picked.
External static pressure
0.030 / 0.040 in. WCAs printed (“.030/.040”); the leaflet does not say what the two values stand for.
Height
7.9 in.width 27.6 in., depth 24.2 in.
Airflow (low / high)
176 / 324 CFM
Sound level (low / high)
32 / 39 dB(A)
Net / gross weight
50.7 / 64 lb
Lines (liquid – gas)
1/4 – 3/8 in.
Condensate
Internal condensate pump
Controls
Wall thermostat and wireless remote included
TOSOT Bathica “Multi Zone Heat Pumps” leaflet (tosotamerica.com), undated, read on November 5, 2026. TOSOT Canada had no sheet for this model on tosot.com on that date.
High static: TOSOT Canada sheets (tosot.com). Low static: undated TOSOT Bathica leaflet; TOSOT Canada had no sheet for these models on November 5, 2026. Indoor-unit values only. TOSOT’s cassette and ducted sheets also give an output and an AHRI number with a single-zone outdoor unit; AirGreen connects these heads to a multi-zone compressor, so those figures do not apply and are not used here.
AirGreen × TOSOT
TOSOT ducted units, live
Each product page: indoor model, dimensions and technical details.
High static reaches 0.6 in. WC (9,000 and 12,000) and 0.8 in. WC (18,000 and 24,000), adjustable in 8 steps. The TOSOT leaflet prints 0.04 in. WC for low static.
TOSOT TM..HSFDI sheets; TOSOT Bathica leaflet.
02
Almost 4 in. more in the ceiling
Low static is 7.9 in. high, high static 11 13/16 in. Those 4 in. have to be planned in the ceiling before choosing.
TOSOT Bathica leaflet; TOSOT TM..HSFDI sheets.
03
Fresh air goes through the high static
TOSOT’s high-static sheets provide a fresh-air knockout and a return from the bottom or the rear.
* Low static: value from the undated TOSOT Bathica leaflet, as printed. High static: TOSOT Canada sheets read on November 5, 2026. Sound: maximum value.
Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.
RBQ 5645-9605-01Subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
LogisVertHydro-Québec never solicits by phone or door to door for LogisVert.
Sources
Sources and reading dates
TOSOT, submittals TM09HSFDI, TM12HSFDI, TM18HSFDI and TM24HSFDI with TW..HXP2A1DO, files of March 7, 2025, tosot.com, read on November 5, 2026; none carries a printed date.
TOSOT Bathica, “Multi Zone Heat Pumps” leaflet (tosotamerica.com), undated, “Slimduct” page, “Low static” table, read on November 5, 2026. No TOSOT sheet for the TM..HFD-I on tosot.com on that date.
Indoor-unit values only. TOSOT’s cassette and ducted sheets also give an output and an AHRI number with a single-zone outdoor unit; AirGreen connects these heads to a multi-zone compressor, so those figures do not apply and are not used here.