AirGreenTOSOT
AirGreen × TOSOT · Sold and installed by AirGreenTOSOT multi-zone at AirGreenOne outdoor unit, 2 to 5 rooms, two compressor families: Lomo 23 and LomoPlus UltraHeat.
The full TOSOT range
TOSOT · Multi-zone · updated November 5, 2026

TOSOT multi-zone: two compressor families, 2 to 5 rooms

One outdoor unit, one head per room. Pick the compressor family and size: you see how many heads it takes, how cold it can heat, the line length allowed and the LogisVert amount that applies.

  • 23TOSOT multi-zone units online
  • 9compressors: 5 Lomo 23 and 4 LomoPlus UltraHeat
  • -35 °CLomoPlus UltraHeat heating, per the TOSOT sheet
  • $3,600LogisVert for the 42,000 LomoPlus UltraHeat (list of October 7, 2026)
01 · Two families, five sizes

Pick the compressor family and size

One outdoor unit for several heads. For each compressor: the number of heads, how cold it can heat, the line length allowed, and the LogisVert amount that applies.

Family

Compressor · BTU/h

LomoPlus UltraHeat · 24,000 (TM24H5O): from 1 to 3 heads, heating down to -35 °C, LogisVert $2,148 (list of October 7, 2026).

LomoPlus UltraHeat · 24,000 BTU/hTM24H5O · AHRI 204344219
Heads
from 1 to 3sizes 9,000 to 24,000 BTU/h
At AirGreen
Dual zone · Tri-zone
Rated output
22,000 cooling, 26,000 BTU/h heating
Heating down to
-35 °C(-31 °F) per the sheet
Certified at -8 °C
17,900 BTU/hENERGY STAR 2409879
Line set
230 ft in total, 82 ft at most per head, 10 ft at least
Height
26 ft outdoor ↔ head, 26 ft between heads
Outdoor unit sound
60 dB(A)
Circuit
MCA 23 A, MOCP 40 A
$2,148Indicative LogisVert amount, Hydro-Québec’s list of October 7, 2026. Calculation: 17,900 BTU/h at -8 °C ÷ 1,000 × $120. Only Hydro-Québec confirms the grant.

Source: TOSOT sheet of November 4, 2024 and ENERGY STAR, read again on November 5, 2026.

LomoPlus UltraHeat: TOSOT sheets of November 4, 2024 and ENERGY STAR, read again on November 5, 2026. Lomo 23: TOSOT sheets read on October 28, 2026. LomoPlus UltraHeat has no 30,000 BTU/h compressor. LogisVert amounts: Hydro-Québec’s list of October 7, 2026.

AirGreen × TOSOT

TOSOT multi-zone units, live

Each product page: outdoor model, AHRI number and the heads offered.

02 · Did you know

Three things to know before choosing a multi-zone

01

One head alone is allowed

The LomoPlus UltraHeat sheets of November 4, 2024 list single-head systems: 9,000 to 24,000 BTU/h on the 18,000 compressor, 12,000 to 24,000 on the 24,000, 18,000 or 24,000 on the 36,000 and 42,000. The Lomo 23 sheets read on October 28, 2026 also gave a minimum of one head.

TOSOT sheets TM18H5O to TM42H5O (November 4, 2024); sheets TM18H4O to TM42H3O (read on October 28, 2026).

02

The 130% rule

TOSOT adds up the heads’ capacity and divides it by the outdoor unit’s: 50 to 150% allowed, 50 to 130% recommended. Above 130%, the sheet warns, the heads deliver less when most of them run at the same time.

TOSOT sheets TM18H5O to TM42H5O, note on the combination table (November 4, 2024).

03

Lomo 23: down to -21 °C

The Lomo 23 compressor sheets, read on October 28, 2026, give heating down to -21 °C (-5 °F). Neither ENERGY STAR nor NEEP has a record for their AHRI numbers, and Hydro-Québec’s list of October 7, 2026 gives them no LogisVert amount.

TOSOT sheets TM18H4O to TM42H3O; ENERGY STAR and NEEP (October 28, 2026); Hydro-Québec’s list of October 7, 2026.

03 · Side by side

The nine compressors side by side

One row per compressor; each name opens its dual-zone product page.

CompressorHeadsHeating down toCertified at -8 °CLogisVertAt AirGreen
Lomo 23 · 18,000TM18H4O1 to 2-21 °C——2 rooms
Lomo 23 · 24,000TM24H4O1 to 3-21 °C——2 · 3 rooms
Lomo 23 · 30,000TM30H4O1 to 4-21 °C——2 · 3 · 4 rooms
Lomo 23 · 36,000TM36H4O1 to 5-21 °C——2 · 3 · 4 rooms
Lomo 23 · 42,000TM42H3O1 to 5-21 °C——2 · 3 · 4 · 5 rooms
LomoPlus UltraHeat · 18,000TM18H5O1 to 2-35 °C17,000 BTU/h$2,0402 rooms
LomoPlus UltraHeat · 24,000TM24H5O1 to 3-35 °C17,900 BTU/h$2,1482 · 3 rooms
LomoPlus UltraHeat · 36,000TM36H5O1 to 4-35 °C29,000 BTU/h$3,4802 · 3 · 4 rooms
LomoPlus UltraHeat · 42,000TM42H5O1 to 5-35 °C30,000 BTU/h$3,6002 · 3 · 4 · 5 rooms

Lomo 23: TOSOT sheets read on October 28, 2026. LomoPlus UltraHeat: TOSOT sheets of November 4, 2024 and ENERGY STAR, read again on November 5, 2026. —: no ENERGY STAR record, and no amount on Hydro-Québec’s list of October 7, 2026.

04 · Multi-zone

The multi-zone pages, each with its question

AirGreen × TOSOT

The right model is chosen at your place, not on a grid

We look at the room, the insulation and the electrical panel, then we propose the model, the quote and the LogisVert amount that applies.

  • Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.
  • RBQ 5645-9605-01Subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
  • LogisVertHydro-Québec never solicits by phone or door to door for LogisVert.
Sources

Sources and reading dates

  1. TOSOT, submittals TM18H5O, TM24H5O, TM36H5O and TM42H5O, dated November 4, 2024, tosot.com, read on November 5, 2026 (specifications, indoor-unit combination table and note on the capacity ratio).
  2. TOSOT, submittals TM18H4O, TM24H4O, TM30H4O, TM36H4O and TM42H3O, undated, read on tosot.com on October 28, 2026 (specifications and combination tables); these files were no longer online there on November 5, 2026.
  3. ENERGY STAR, “Certified Air-Source Heat Pumps” dataset (w7cv-9xjt), records 2409880, 2409879, 2415664 and 2415663 (AHRI 204344218 to 204344221), read again on November 5, 2026.
  4. ENERGY STAR and NEEP: no record for AHRI numbers 10064017, 10064019, 10064021, 10064023 and 10064025 (searched on October 28, 2026).
  5. Hydro-Québec, “Heat pump search tool”, list of October 7, 2026 (LogisVert amounts).
  6. Hydro-Québec, LogisVert program, Participant’s guide for residential customers, version 1.10, September 15, 2026.

LogisVert amounts come from Hydro-Québec’s list on the date shown; only Hydro-Québec confirms the grant. AHRI numbers are those on our product pages, unchanged.