One head is enough
The sheet for the 36,000 Lomo 23 compressor, read on October 28, 2026, says it outright: a single head is enough to run the system. It also gives the output of each head alone, from 9,000 to 24,000 BTU/h.
TOSOT sheet TM36H4O.
The Lomo 23 compressor sheets allow a single head to start. Pick the compressor and the first head: you see what the sheet says about that head alone, and the possible pairs when the second one arrives.
What the sheet says about that head alone, then the possible pairs when the second one arrives, with your first head’s share.
Compressor · BTU/h
First head · BTU/h
TM24H4O with a 12,000 head: allowed to start per the sheet read on October 28, 2026; 3 possible pairs afterwards.
When the second head arrives: the pairs the sheet lists
| Second head | System, cooling / heating | Your first head, cooling / heating |
|---|---|---|
| + 9,000 | 21,000 / 22,500 | 12,000 / 13,000 |
| + 12,000 | 24,000 / 26,000 | 12,000 / 13,000 |
| + 18,000 | 25,000 / 28,000 | 10,000 / 11,200 |
TOSOT sheets for the Lomo 23 compressors, read on October 28, 2026; outputs at AHRI test conditions (95 °F cooling, 47 °F heating). A pale chip: head size not among this compressor’s combinations.
Each product page: outdoor model, AHRI number and the heads offered.
The sheet for the 36,000 Lomo 23 compressor, read on October 28, 2026, says it outright: a single head is enough to run the system. It also gives the output of each head alone, from 9,000 to 24,000 BTU/h.
TOSOT sheet TM36H4O.
On the 24,000 Lomo 23, the 12,000 + 18,000 pair gives 25,000 BTU/h in cooling: 10,000 for the 12,000 head and 15,000 for the 18,000 head, per the sheet read on October 28, 2026.
TOSOT sheet TM24H4O, combination table.
Neither ENERGY STAR nor NEEP has a record for the AHRI numbers of the Lomo 23 multi-zone compressors, and Hydro-Québec’s list of October 7, 2026 gives them no LogisVert amount.
ENERGY STAR and NEEP (October 28, 2026); Hydro-Québec’s list of October 7, 2026.
The heads each sheet takes, and what it publishes for a single head.
| Compressor | Head sizes | Pairs listed | Single head published | Line set | Circuit |
|---|---|---|---|---|---|
| Lomo 23 · 18,000TM18H4O | 9,000 · 12,000 | 3 | listed, no per-head output | 65 ft in total · 33 ft per head | MCA 16 A · MOCP 25 A |
| Lomo 23 · 24,000TM24H4O | 9,000 · 12,000 · 18,000 | 6 | no | 197 ft in total · 65 ft per head | MCA 23 A · MOCP 30 A |
| Lomo 23 · 30,000TM30H4O | 9,000 · 12,000 · 18,000 · 24,000 | 9 | no | 230 ft in total · 82 ft per head | MCA 20 A · MOCP 30 A |
| Lomo 23 · 36,000TM36H4O | 9,000 · 12,000 · 18,000 · 24,000 | 10 | yes, 4 sizes | 246 ft in total · 82 ft per head | MCA 23 A · MOCP 35 A |
| Lomo 23 · 42,000TM42H3O | 9,000 · 12,000 · 18,000 · 24,000 | 10 | no | 246 ft in total · 82 ft per head | MCA 24 A · MOCP 40 A |
TOSOT sheets read on October 28, 2026. MCA: minimum circuit ampacity; MOCP: maximum overcurrent protection.
We look at the room, the insulation and the electrical panel, then we propose the model, the quote and the LogisVert amount that applies.
LogisVert amounts come from Hydro-Québec’s list on the date shown; only Hydro-Québec confirms the grant. AHRI numbers are those on our product pages, unchanged.