One cabinet for four sizes
From 9,000 to 24,000 BTU/h, the cabinet keeps its 48.0 × 27.6 × 8.9 in. You pick the size for the room, not for the space.
TOSOT Bathica leaflet, “Floor-Ceiling” page.
One cabinet for all four sizes: 48.0 × 27.6 × 8.9 in. On the floor it stands 27.6 in. high; on the ceiling it drops only 8.9 in. Pick the position, see what sticks out.
The same 48 in. cabinet, standing on the floor against the wall or hung from the ceiling. The dimensions do not change; what sticks out into the room does.
Position
Size · BTU/h
TM12HTD-I on the ceiling: 8.9 in. below the ceiling, 88.1 lb to hang.
TOSOT Bathica “Multi Zone Heat Pumps” leaflet (tosotamerica.com), undated, read on November 5, 2026. TOSOT Canada had no sheet for this model on tosot.com on that date.
Values from the undated TOSOT Bathica “Multi Zone Heat Pumps” leaflet: TOSOT Canada had no sheet for these models on tosot.com on November 5, 2026.
Each product page: indoor model, dimensions and technical details.
From 9,000 to 24,000 BTU/h, the cabinet keeps its 48.0 × 27.6 × 8.9 in. You pick the size for the room, not for the space.
TOSOT Bathica leaflet, “Floor-Ceiling” page.
The 9,000, 12,000 and 18,000 weigh 88.1 lb; the 24,000, 99.2 lb. On the ceiling, that is the weight being hung.
TOSOT Bathica leaflet, “Floor-Ceiling” page.
On the 42,000 BTU/h multi-zone compressors, the TOSOT brochure keeps the 24,000 head for cassettes, ducted units and floor-ceiling units, not wall units.
TOSOT Bathica “Heat Pumps” brochure, undated.
Same cabinet; weight, airflow and sound size by size.
| Size | Net weight | Airflow (low / high) | Sound (low / high) | Lines |
|---|---|---|---|---|
| 9,000TM09HTD-I | 88.1 lb | 265 / 383 CFM | 36 / 40 dB(A) | 1/4 – 3/8 in. |
| 12,000TM12HTD-I | 88.1 lb | 265 / 383 CFM | 36 / 40 dB(A) | 1/4 – 3/8 in. |
| 18,000TM18HTD-I | 88.1 lb | 294 / 559 CFM | 40 / 45 dB(A) | 1/4 – 1/2 in. |
| 24,000TM24HTD-I | 99.2 lb | 412 / 736 CFM | 44 / 48 dB(A) | 3/8 – 5/8 in. |
Values from the undated TOSOT Bathica leaflet, read on November 5, 2026.
We look at the room, the insulation and the electrical panel, then we propose the model, the quote and the LogisVert amount that applies.
Indoor-unit values, as the TOSOT leaflet prints them.