TOSOT five-zone: what TOSOT really publishes for five rooms

Two 42,000 BTU/h compressors take five heads, but not just any five. Pick the size for each room: you see whether the combination is on TOSOT’s list, and what the sheet says about it.

  • 2five-zone compressors online
  • 4five-head combinations, LomoPlus UltraHeat (sheet of November 4, 2024)
  • 2five-head combinations, Lomo 23 (sheet read on October 28, 2026)
  • 39,700 BTU/hcooling for 9,000 × 4 + 12,000 on the Lomo 23 (sheet read on October 28, 2026)
01 · The five-head combinations

Five rooms: is your combination on TOSOT’s list?

Pick the head for each room. The two 42,000 BTU/h compressors take only a few five-head combinations; the tool shows which ones, and what the sheet publishes.

Room 1 · BTU/h

Room 2 · BTU/h

Room 3 · BTU/h

Room 4 · BTU/h

Room 5 · BTU/h

Your heads: 9,000 + 9,000 + 9,000 + 9,000 + 12,000 = 48,000 BTU/h. 2 of 2 compressors accept it.

  1. ListedLomo 23 · 42,000TM42H3O · TOSOT sheet read on October 28, 2026System output per TOSOT: 39,700 BTU/h cooling (only this table was recorded).
  2. ListedLomoPlus UltraHeat · 42,000TM42H5O · list in the TOSOT sheet of November 4, 2024Heads 48,000 BTU/h ÷ compressor 42,000 BTU/h = 114% (within TOSOT’s recommended range, 50 to 130%).

LomoPlus UltraHeat: combination table in the TOSOT sheet of November 4, 2024, limited to the head sizes AirGreen offers (9,000 to 24,000 BTU/h); the ratio compares the sum of the heads with the compressor size, as TOSOT’s note does. Lomo 23: combination tables in the TOSOT sheets read on October 28, 2026, system output at AHRI test conditions (95 °F cooling, 47 °F heating). The final choice is made on site.

AirGreen × TOSOT

TOSOT five-zone units, live

Each product page: outdoor model, AHRI number and the heads offered.

02 · Did you know

Three things the sheets say about five heads

01

Mostly 9,000 heads

The four five-head combinations on the 42,000 LomoPlus UltraHeat all include at least two 9,000 heads. The two largest add up to 54,000 BTU/h, 129% of the compressor: within TOSOT’s recommended range, close to its limit.

TOSOT sheet TM42H5O, combination table (November 4, 2024).

02

Past 131 ft, refrigerant

Five heads at 30 ft each make 150 ft of line: 19 ft more than the 42,000 LomoPlus UltraHeat’s pre-charged length, about 4 oz of refrigerant to add at 0.21 oz per foot.

Calculated from TOSOT sheet TM42H5O (November 4, 2024).

03

A circuit protected at 60 A

The 42,000 LomoPlus UltraHeat needs a circuit of at least 38 A (MCA), protected at 60 A at most (MOCP); the 42,000 Lomo 23, 24 A and 40 A per its sheet read on October 28, 2026.

TOSOT sheets TM42H5O (November 4, 2024) and TM42H3O.

03 · Side by side

The two 42,000 compressors, line by line

Same size on paper, two different sheets.

Lomo 23 · 42,000TM42H3OLomoPlus UltraHeat · 42,000TM42H5O
5-head combinations29,000 × 5
9,000 × 4 + 12,000
49,000 × 5
9,000 × 4 + 12,000
9,000 × 4 + 18,000
9,000 × 2 + 12,000 × 3
Published 5-head outputcooling 39,600 to 39,700not published
Heating down to-21 °C-35 °C
Certified at -8 °C—30,000 BTU/h
LogisVert (list of October 7, 2026)—$3,600
Line set in total246 ft262 ft
Pre-charged for131 ft131 ft
Outdoor unit sound61 dB(A)62 dB(A)
Circuit (MCA / MOCP)24 A / 40 A38 A / 60 A

Lomo 23 (TM42H3O): TOSOT sheet read on October 28, 2026; only its cooling table was recorded. LomoPlus UltraHeat (TM42H5O): TOSOT sheet of November 4, 2024 and ENERGY STAR, read again on November 5, 2026.

04 · Multi-zone

The multi-zone pages, each with its question

AirGreen × TOSOT

The right model is chosen at your place, not on a grid

We look at the room, the insulation and the electrical panel, then we propose the model, the quote and the LogisVert amount that applies.

  • Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.
  • RBQ 5645-9605-01Subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
  • LogisVertHydro-Québec never solicits by phone or door to door for LogisVert.
Sources

Sources and reading dates

  1. TOSOT, submittals TM18H5O, TM24H5O, TM36H5O and TM42H5O, dated November 4, 2024, tosot.com, read on November 5, 2026 (specifications, indoor-unit combination table and note on the capacity ratio).
  2. TOSOT, submittals TM18H4O, TM24H4O, TM30H4O, TM36H4O and TM42H3O, undated, read on tosot.com on October 28, 2026 (specifications and combination tables); these files were no longer online there on November 5, 2026.
  3. ENERGY STAR, “Certified Air-Source Heat Pumps” dataset (w7cv-9xjt), records 2409880, 2409879, 2415664 and 2415663 (AHRI 204344218 to 204344221), read again on November 5, 2026.
  4. Hydro-Québec, “Heat pump search tool”, list of October 7, 2026 (LogisVert amounts).
  5. TOSOT, “Heat Pumps” brochure in English, undated: note on the 24,000 BTU/h size with the 42,000 BTU/h compressors.

LogisVert amounts come from Hydro-Québec’s list on the date shown; only Hydro-Québec confirms the grant. AHRI numbers are those on our product pages, unchanged.