More than four times the head’s weight
The Hyper Heat 24,000 outdoor unit weighs 134.48 lb net; its head, 29.98 lb. When we talk wall brackets, the outdoor unit is what counts.
NOVAIR Hyper Heat brochure
NOVAIR // Wall heat pumps
Can it go where you want it?
A wall unit is a head in the room and a unit outside, joined by a refrigerant line set and a communication wire. Before picking a model, we check that your run fits the NOVAIR brochures: line length, height difference, circuit, weight and noise.
01 · Your installation
Pick the series and size, then enter the planned line length and the height difference between the two units. Measure the line the way it will be installed, bends and detours included, not in a straight line.
Result · Hyper Heat 12,000 · LEA12SZ35SK-O + 2LEA12UUSK-I
Line length and height difference are both within the brochure maximums for this size.
42 ft to spare
23 ft to spare
The brochure gives one maximum height difference per size, whichever unit sits higher.
40 dB(A): “a place perceived as peaceful”. 50 dB(A): “where disturbance begins”. Source: Québec.ca, in French.
Sound pressure levels as NOVAIR publishes them, with no test conditions: a reference point, not a reading in your home. Same head in both series, but the brochures don’t print the same levels: we show the ones for the series you picked. At night, in a bedroom, low speed is what matters.
02 · The comparison that matters
For the installer, the two 24,000 units look alike: same 3/8-5/8 line set, same 164 ft of line and 82 ft of height difference, same outdoor dimensions. What changes is the circuit, the weight on the bracket and the noise outside.
| Item | Ultra Heat 24,000 | Hyper Heat 24,000 |
|---|---|---|
| What changes | ||
| Outdoor unit | LEA24SZ25SK-O | LEA24SZ35SK-O |
| Net weight, outdoor unit | 124.78 lb | 134.48 lb |
| Sound, outdoor unit | 60 dB(A) | 62 dB(A) |
| “Minimum Ampacity” | 22 A | 25 A |
| Second row, “MCA” | 30 A | 35 A |
| What stays the same | ||
| Line set | 3/8-5/8 | 3/8-5/8 |
| Max. line length | 164 ft | 164 ft |
| Max. height difference | 82 ft | 82 ft |
| Dimensions, outdoor unit | 37.24 × 16.14 × 31.89 in | 37.24 × 16.14 × 31.89 in |
| Net weight, head | 29.98 lb | 29.98 lb |
| Power | 208/230 V | 208/230 VThe brochure prints “280/230V”, a typo. |
Choosing between the two comes down to heat in deep cold. This page only covers the install; the rest is on the NOVAIR page.
This page sticks to installation. For the rest:
03 · Did you know
The Hyper Heat 24,000 outdoor unit weighs 134.48 lb net; its head, 29.98 lb. When we talk wall brackets, the outdoor unit is what counts.
NOVAIR Hyper Heat brochure
The brochure allows 82 ft of line at 9,000 and 12,000, 98 ft at 18,000 and 164 ft at 24,000. Height difference follows: 33, 66, then 82 ft.
NOVAIR Ultra Heat and Hyper Heat brochures
NEEP and ENERGY STAR list the same indoor unit, 2LEA24UUSK-I, for both 24,000 series. The Ultra Heat brochure gives it as 42.64 × 9.61 × 13.27 in, the Hyper Heat brochure as 46.85 × 11.2 × 14.59 in. We measure the head on site before drilling the wall.
NOVAIR brochures, NEEP and ENERGY STAR
Send us a photo of the wall where the head will go and of the spot planned outside: we confirm the run during the on-site assessment of heating needs.