NOVAIR

NOVAIR // Wall heat pumps

NOVAIR wall heat pump

Can it go where you want it?

A wall unit is a head in the room and a unit outside, joined by a refrigerant line set and a communication wire. Before picking a model, we check that your run fits the NOVAIR brochures: line length, height difference, circuit, weight and noise.

  • 8 models online
  • Ultra Heat and Hyper Heat
  • 9,000 to 24,000 BTU/h

01 · Your installation

Your line run, checked against the brochure

Pick the series and size, then enter the planned line length and the height difference between the two units. Measure the line the way it will be installed, bends and detours included, not in a straight line.

Series
Size (BTU/h)
Units
ft

Numbers only, for example 40 or 12.5.

ft
The outdoor unit sits

Check result

Result · Hyper Heat 12,000 · LEA12SZ35SK-O + 2LEA12UUSK-I

Your run fits the NOVAIR brochure.

Line length and height difference are both within the brochure maximums for this size.

Line length: 40 ft max. 82 ft

42 ft to spare

Height difference: 10 ft, outdoor unit below max. 33 ft

23 ft to spare

The brochure gives one maximum height difference per size, whichever unit sits higher.

What the install needs

Line set
1/4 in (liquid) and 1/2 in (gas)
Communication wire
14 AWG × 4, stranded, unshielded
Power
208/230 V, single phase, 60 Hz
Circuit, per the brochure
“Minimum Ampacity”: 15 A
second row, also labelled “MCA”: 15 ATwo rows, two labels, as NOVAIR prints them. The circuit is chosen from the outdoor unit’s nameplate, on site.
Indoor unit 2LEA12UUSK-I
33.40 × 9.18 × 11.76 in · 18.74 lb netUltra Heat brochure, same head: 31.57 × 7.87 × 11.61 in
Outdoor unit LEA12SZ35SK-O
31.69 × 12.99 × 21.81 in · 73.63 lb net

Noise, on the Québec.ca scale

  • Head, low speed: 24 dB(A), below the 40 dB(A) mark
  • Head, medium speed: 36 dB(A), below the 40 dB(A) mark
  • Head, high speed: 41.5 dB(A), between the 40 and 50 dB(A) marks
  • Outdoor unit: 56 dB(A), as NOVAIR publishes it, with no measuring distance, so we don’t place it on the Québec.ca scale

40 dB(A): “a place perceived as peaceful”. 50 dB(A): “where disturbance begins”. Source: Québec.ca, in French.

Sound pressure levels as NOVAIR publishes them, with no test conditions: a reference point, not a reading in your home. Same head in both series, but the brochures don’t print the same levels: we show the ones for the series you picked. At night, in a bedroom, low speed is what matters.

See the Hyper Heat 12,000 page

02 · The comparison that matters

Ultra Heat or Hyper Heat at 24,000: same install, different circuit

For the installer, the two 24,000 units look alike: same 3/8-5/8 line set, same 164 ft of line and 82 ft of height difference, same outdoor dimensions. What changes is the circuit, the weight on the bracket and the noise outside.

Ultra Heat 24,000 and Hyper Heat 24,000, installation data from the NOVAIR brochures
ItemUltra Heat 24,000Hyper Heat 24,000
What changes
Outdoor unitLEA24SZ25SK-OLEA24SZ35SK-O
Net weight, outdoor unit124.78 lb134.48 lb
Sound, outdoor unit60 dB(A)62 dB(A)
“Minimum Ampacity”22 A25 A
Second row, “MCA”30 A35 A
What stays the same
Line set3/8-5/83/8-5/8
Max. line length164 ft164 ft
Max. height difference82 ft82 ft
Dimensions, outdoor unit37.24 × 16.14 × 31.89 in37.24 × 16.14 × 31.89 in
Net weight, head29.98 lb29.98 lb
Power208/230 V208/230 VThe brochure prints “280/230V”, a typo.

Choosing between the two comes down to heat in deep cold. This page only covers the install; the rest is on the NOVAIR page.

The rest, on the NOVAIR page

This page sticks to installation. For the rest:

Who brings what

  • NOVAIRThe units, their brochures and their installation limits.
  • AirGreenThe on-site assessment of heating needs, the line run and the installation by our refrigeration technicians.

03 · Did you know

Three details from the NOVAIR brochures

More than four times the head’s weight

The Hyper Heat 24,000 outdoor unit weighs 134.48 lb net; its head, 29.98 lb. When we talk wall brackets, the outdoor unit is what counts.

NOVAIR Hyper Heat brochure

Twice the line at 24,000

The brochure allows 82 ft of line at 9,000 and 12,000, 98 ft at 18,000 and 164 ft at 24,000. Height difference follows: 33, 66, then 82 ft.

NOVAIR Ultra Heat and Hyper Heat brochures

Same head, two sets of dimensions

NEEP and ENERGY STAR list the same indoor unit, 2LEA24UUSK-I, for both 24,000 series. The Ultra Heat brochure gives it as 42.64 × 9.61 × 13.27 in, the Hyper Heat brochure as 46.85 × 11.2 × 14.59 in. We measure the head on site before drilling the wall.

NOVAIR brochures, NEEP and ENERGY STAR

Let’s talk about your line run

Send us a photo of the wall where the head will go and of the spot planned outside: we confirm the run during the on-site assessment of heating needs.

Sources
  • NOVAIR, “Hyper Heat Series” brochure (2 pages, modified December 8, 2025), read November 23, 2026
    Open the brochure (PDF)
  • NOVAIR, “Ultra Heat Series” brochure (2 pages, modified December 8, 2025), read November 23, 2026
    Open the brochure (PDF)
  • NEEP cold-climate heat pump list and ENERGY STAR certified heat pump list: indoor and outdoor models, read November 23, 2026
  • Québec.ca, noise measurement page (“Mesure du bruit”, in French), updated June 16, 2022
    Open the page