VTAC installation and replacement in Montréal, Laval, Longueuil, South Shore and North Shore
A VTAC is the vertical terminal air conditioner hidden in a closet: it cools and heats the room. We help you understand it, find the exact replacement for yours, then install it and wire it. 100% free on-site estimate.
Call us at 514 316-2973 or write to sales@airgreen.ca for your free estimate.
The VTAC: an air conditioner and a heat pump in a closet.
VTAC stands for vertical terminal air conditioner. Pick a mode, slide the temperature, tap the numbers.
Cool
Summer: the room’s heat goes outside through the louver. Cool air comes out of the ceiling diffuser.
Tap a number on the drawing to see each part.
Demo: the actual mode also depends on the thermostat and the temperature you want in the room.
Type the model number. We read it with you.
Every character means something: capacity, heat, voltage, refrigerant.
Where to find it: open the closet’s grille door; the number is on the unit’s label. A photo works too.
Same capacity, same heat, same 23 × 23 in base.
Same footprint, four heights: find yours.
Pick the capacity and the built-in heat; the numbers come from the Friedrich spec sheet.
To scale: all four chassis share the same 23 × 23 in base. Only the height changes. The figure is 5 ft 8 in tall.
VERT-I-PAK 12,000 BTU
VHA12K34RTPFriedrich ratings for the R-410A (RTP) generation in our catalogue. Our electricians confirm the breaker size on site.
The numbers, side by side
Friedrich certified ratings, R-410A (RTP) generation. Tap a column to select it above.
One unit or the whole building: tap the suites to equip.
The number of suites you pick fills in the form at the top of the page.
Condo
Replacement in the existing closets, one suite at a time or the whole building. We measure every closet and plan the work with the property manager.
Every Friedrich VTAC in our catalogue, in one table.
Filter by capacity; each row links to the product page. The photos and spec sheets come from our product pages.






Photos and spec sheets from our product pages
Tap a thumbnail to see the unit, then its spec sheet. The first image is this collection’s.
| Model | Capacity | Cooling | Heat pump | Heating | Breaker | Airflow | Chassis (in) | |
|---|---|---|---|---|---|---|---|---|
| VHA09K25RTP | 9,000 | 9,300 BTU/h | 8,300 BTU/h | 2.5 kW | 20 A | 490 CFM | 23 × 23 × 32 | Page |
| VHA09K34RTP | 9,000 | 9,300 BTU/h | 8,300 BTU/h | 3.4 kW | 25 A | 490 CFM | 23 × 23 × 32 | Page |
| VHA09K50RTP | 9,000 | 9,300 BTU/h | 8,300 BTU/h | 5 kW | 30 A | 490 CFM | 23 × 23 × 32 | Page |
| VHA12K25RTP | 12,000 | 11,500 BTU/h | 10,600 BTU/h | 2.5 kW | 20 A | 490 CFM | 23 × 23 × 32 | Page |
| VHA12K34RTP | 12,000 | 11,500 BTU/h | 10,600 BTU/h | 3.4 kW | 25 A | 490 CFM | 23 × 23 × 32 | Page |
| VHA12K50RTP | 12,000 | 11,500 BTU/h | 10,600 BTU/h | 5 kW | 30 A | 490 CFM | 23 × 23 × 32 | Page |
| VHA18K25RTP | 18,000 | 18,400 BTU/h | 16,700 BTU/h | 2.5 kW | 20 A | 675 CFM | 23 × 23 × 47 | Page |
| VHA18K34RTP | 18,000 | 18,400 BTU/h | 16,700 BTU/h | 3.4 kW | 25 A | 675 CFM | 23 × 23 × 47 | Page |
| VHA18K50RTP | 18,000 | 18,400 BTU/h | 16,700 BTU/h | 5 kW | 30 A | 675 CFM | 23 × 23 × 47 | Page |
| VHA24K25RTP | 24,000 | 22,500 BTU/h | 19,500 BTU/h | 2.5 kW | 20 A | 700 CFM | 23 × 23 × 52 | Page |
| VHA24K34RTP | 24,000 | 22,500 BTU/h | 19,500 BTU/h | 3.4 kW | 25 A | 700 CFM | 23 × 23 × 52 | Page |
| VHA24K50RTP | 24,000 | 22,500 BTU/h | 19,500 BTU/h | 5 kW | 30 A | 700 CFM | 23 × 23 × 52 | Page |
| VHA24K75RTP | 24,000 | 22,500 BTU/h | 19,500 BTU/h | 7.5 kW | 45 A | 700 CFM | 23 × 23 × 52 | Page |
| VHA24K10RTP | 24,000 | 22,500 BTU/h | 19,500 BTU/h | 10 kW | 60 A | 700 CFM | 23 × 23 × 52 | Page |
VTAC, PTAC or wall heat pump: which one fits you?
Pick a question; all three answers change at once.
In a closet, against an outside wall.
You are hereA head on the room’s wall, a compressor outside.
See wall heat pumpsWhat’s going on with your unit?
Pick what you see. We’ll tell you straight what to do.
It blows, but doesn’t cool anymore
It needs measuring: filter, coil, refrigerant charge or compressor. If it’s the compressor and the unit is less than 5 years old, the sealed-system warranty may apply; otherwise we compare repair and replacement.
Request a service callService call fees are stated before the visit.
Six two-minute checks before our visit.
Tap a line to see it on the drawing, tick what you’ve checked.
Not sure about a measurement? Leave it: that’s what we come to do, free.
The heat you choose decides the breaker.
The 12,000 BTU unit comes with 2.5 kW, 3.4 kW or 5 kW of electric heat.
Figures: maximum breaker (MOP) at 230 V from the 2023 Friedrich spec sheet. More electric heat means more comfort in extreme cold, but a bigger circuit. We check your panel during the estimate; our electricians do the wiring (RBQ licence 16).
From R-410A to R-32: three generations, same closet.
The chassis and accessories (wall sleeve, louver, grille) keep the same dimensions from one generation to the next. Pick a generation:
Note: the “2” ratings come from a tougher test method. An EER2 of 10.6 does not mean worse than an EER of 11.0.
What Friedrich covers, month by month.
Slide to your unit’s age.
1 year and 6 months after installation
Bottom line: The compressor, coils and tubing are covered. The other parts (fans, circuit board) no longer are.
R-410A or R-32?
The models in our catalogue (ending in RTP) use R-410A. Friedrich now builds the VERT-I-PAK with R-32 (ending in RCQ), with SEER2 and EER2 ratings.
For you: an R-410A unit can still be repaired. For a new unit, your estimate states in writing which generation we install.
A VTAC cools and heats. To breathe, add an air exchanger.
The VERT-I-PAK’s fresh-air damper lets in 60 CFM at most. Click to see the difference.
The air exchangers we install
A VTAC conditions the air; it barely renews it. An air exchanger removes humidity and stale air and brings in fresh air while recovering the heat. We install both, and we wire them.
See all air exchangersFriedrich for the VTAC, and every brand around it.
For VTACs, it’s Friedrich VERT-I-PAK. For under-window units (PTAC) and ventilation, we install the brands below. Filter:
From the first call to start-up, in six steps.
Call or form
Tell us how many units, the floor and, if you can, the current model number. A photo of the nameplate helps a lot.
The questions we get about VTACs
One unit or the whole building: we handle it from the closet to the electrical panel.
Replacing one unit or a whole building: we come and measure, give you a written price, install and wire. The on-site estimate is free.
- Friedrich, VERT-I-PAK Product Profile (R-410A, RTP generation) (VPAK PP FEB-2023, 95214200_13)
- Friedrich, VERT-I-PAK Product Profile (R-32, RCQ generation) (FFR-104 Rev 02, 09/2026)
- Friedrich, VERT-I-PAK brochure 2026 (MFR-9002 REV 10, 09/2026)
- Friedrich, VERT-I-PAK installation manual (A2L) (92000100_04, 09/2026)
- Friedrich, PTAC and VTAC limited warranty (U.S. and Canada) (99304401_00 Rev 1, 09/2026)
- Natural Resources Canada, single package vertical air conditioners and heat pumps (page modified January 6, 2026)
- Hydro-Québec, LogisVert, participation guide (version 1.10, September 15, 2026)
The specs shown are for the VERT-I-PAK generation in our catalogue (R-410A, RTP suffix). Friedrich now sells an R-32 generation (RCQ suffix): we confirm the exact model and its data in your estimate. Our electricians confirm the electrical ratings on site.