APRILAIRE 600 and GENERALAIRE GF1042, evaporative humidifiers

Home / Comparisons / Evaporative humidifiers

Comparison · Evaporative humidifiers · bypass

APRILAIRE 600 and GENERALAIRE GF1042, the water that evaporates

Both mount on the furnace plenum. Part of the warm air passes through a wet pad, comes out more humid and returns through a bypass duct. Their output therefore depends on how warm that air is; each manufacturer states the temperature it measures at.

Published output at 49 °C (120 °F) · 17 gal/day · 17 gal/day Bypass duct · 6 in., both Power · 24 V
GeneralAire GF1042DMD humidifier, AirGreen product card
GeneralAire

GENERALAIRE GF1042

GF-1042DMD / DMM · Vapor Pad GF-990-13 · GF-X3 / GF-MHX3

See the product page
The water that evaporates

What each one evaporates, depending on how warm the plenum air is

Pick a plenum air temperature. The page shows an output only where a manufacturer publishes one; at 49 °C, both current documents give the same figure, measured at the same temperature.

No “Cost per season” block on this page: a humidifier has no HSPF2 or SEER2, so the cost method of our heat pump comparisons does not apply.

Water per hour

What goes in, what evaporates, what goes down the drain

Both models let more water run than they evaporate: the excess rinses the pad and carries the minerals to the drain. Feed and evaporation rates come from the manufacturers; the water to drain is our subtraction.

Installation

An opening in the plenum and a 6 in. bypass duct

Both hang vertically on a supply or return plenum. Their openings are not the same shape: the AprilAire needs a taller opening, the GeneralAire a wider one.

The openings to cut, at the same scale

Both units at the same scale

AprilAire 600, cut-out photo
15 3/8 in.
APRILAIRE 600height 15 3/4 in.
GeneralAire GF1042, cut-out photo
15 1/8 in.
GENERALAIRE GF1042height 14 in.

Photos scaled to the height each manufacturer publishes; the line under each photo shows the published width. The original photo framing crops the bottom of the GeneralAire.

InstallationAPRILAIRE 600GENERALAIRE GF1042
Plenum mounting
Plenum opening10 in. wide × 12 3/4 in. high13 5/8 in. wide × 9 1/2 in. high
Bypass duct6 in., round6 in., galvanized pipe
Supply or return plenumAir passes from the supply duct to the return duct (owner's manual)Warm or return plenum, “with equal efficiency”
Stated ambient rangeNot published by the manufacturer in the 2023 sheet.Not below 0 °C (32 °F); plenum up to 93 °C (200 °F)
Water and drain
Water feed rate3 gal/h (11.4 L/h)About 3.5 gal/h (13.2 L/h) at 60 psiorifice GF-9903776; GF-9903775 at 20 to 40 psi
Hot or cold waterOutput published with cold water; hot water (60 °C max) is advised, and required with a heat pumpCold or hot; hot water can raise output by up to 30 %, copper tubing required
DrainContinuous slope to the drain, no kinks or blockage5/8 in. hose, 15 ft supplied; floor drain, laundry sink or condensate pump
Electrical and size
Power supply24 V, 60 Hz, 0.5 A24 V; 2.5 W running; transformer supplied
Dimensions W × H × D15 3/8 × 15 3/4 × 10 1/4 in.15 1/8 × 14 × 9 in.
Humidifier, weight10 lb13 lb
Features

What each manufacturer writes, line by line

Wall control supplied

AprilAire: Model 60 automatic digital control, 10 to 45 %, ±3 % accuracy (Model 600). The 600M comes with the 4655 manual control.

GeneralAire: GF-X3 digital humidistat with the GF-1042DMD; GF-MHX3 manual humidistat with the GF-1042DMM.

AprilAireGeneralAire
Blower operation

AprilAire: blower activation may be needed on a heat pump or a furnace with short cycles.

GeneralAire: GF-GA50 current-sensing relay and GF-12500 air pressure switch among the material that may be needed.

AprilAireGeneralAire
Pad upkeep

AprilAire: Model 35 water panel, changed once a season, cleaning the housing at the same time.

GeneralAire: GF-990-13 Vapor Pad, at least once a year per the sheet; the manual also writes “1 to 2 times per season”.

AprilAireGeneralAire
Summer damper

AprilAire: close the bypass damper for the summer.

GeneralAire: shut off water and power, close the air damper for the summer.

AprilAireGeneralAire
FAQ

Questions about these two humidifiers

Why do both show 17 gallons a day?

Because both manufacturers measure at the same point: a plenum at 49 °C (120 °F). AprilAire adds that the blower runs all the time and the water is cold. At 60 °C (140 °F), older documents give 22 gal/day for the AprilAire 600 (form 293, 2013) and 19 gal/day for GeneralAire's 1042LH (January 2012 brochure).

And with a heat pump?

The two manufacturers do not say the same thing. AprilAire's application guide puts heat pump plenums at 90 to 100 °F (32 to 38 °C) and lists the 600 series there, with hot water (60 °C max) and blower activation, without putting a number on output. GeneralAire writes that the unit “is not recommended for heat pumps” and that the published output needs a plenum at 120 °F or more. Our steam versus evaporative comparison takes up the question.

What size of house?

AprilAire gives a table of needs in gal/day by floor area and tightness, with 8 ft ceilings: 17 gal/day matches about 2,500 sq ft of average construction (16.7 gal/day) and 5,000 sq ft of tight construction. GeneralAire writes “up to 2,800 sq ft” on its 2021 sheet and “up to 3,000 sq ft” in its manual. The methods differ.

DMD or DMM at GeneralAire?

GeneralAire's sheet describes both under one model; only the control changes: GF-X3 digital humidistat with the DMD, GF-MHX3 manual humidistat with the DMM.

Is a drain needed?

Yes for both: the water that does not evaporate leaves at the bottom. GeneralAire supplies 15 ft of 5/8 in. hose and names a floor drain, laundry sink or condensate pump. AprilAire asks for a continuous slope, without kinks.

Why not compare the warranties?

Our comparisons do not compare warranties. Each manufacturer's warranty documents come with the quote.

Full spec sheet

Every published value, in one place

ValueAPRILAIRE 600GENERALAIRE GF1042
Published output
Output at 49 °C (120 °F) plenum17 gal/day0.7 gal/h; blower on 100 % of the time, cold water17 gal/day“based on 120 °F / 49 °C plenum temperature”
Output at 60 °C (140 °F) plenum22 gal/dayform 293, 201319 gal/day1042LH brochure, January 2012
With a heat pump600 series listed for 90 to 100 °F plenums, hot water and blower activation“Not recommended for heat pumps”
Parts and control
Evaporator padModel 35Vapor Pad GF-990-13
Humidistat suppliedModel 60 (600) or 4655 (600M)GF-X3 (DMD) or GF-MHX3 (DMM)
Size
Dimensions W × H × D15 3/8 × 15 3/4 × 10 1/4 in.15 1/8 × 14 × 9 in.
Humidifier, weight10 lb13 lb

US gallons. Values per the manufacturers' documents cited below; none is certified by a third party. The 60 °C values come from older documents than the other lines.