Heat pump in a condo: syndicate, drain, location, noise

Home › Comparisons › Guides
Comparison · Guide · Condominium

Heat pump in a condo: syndicate, drain, location, noise

In a condo, the outdoor unit sits on a balcony or a wall that often isn't entirely yours. Four questions need settling before the quote. The answers come from your declaration of co-ownership, the official texts and the manufacturer's manual.

Example FUJITSU AIRSTAGE ORION XLTH 12,000 BTU, AirGreen product card FUJITSU AIRSTAGE

ORION XLTH 12,000 BTU/h

Indoor ASUH12KZAS · outdoor AOUH12KZAH1 · AHRI 214888802

The dimensions, clearances and water instructions quoted in this guide are those of this wall unit, chosen as an example among the ones AirGreen offers. Each model has its own manual.

View the product page
The balcony in section

Your balcony seen from the side, with the outdoor unit to scale

Set your balcony depth and the season. Tap a number to see what the texts and the manual say at that spot.

FUJITSU AIRSTAGE AOUH12KZAH1 outdoor unit
The example's outdoor unit, AOUH12KZAH1: 31 7/16 in wide, 86 lb (spec sheet FG8153C). Photo.

Section drawing. To scale: the balcony depth, the profile of the example's outdoor unit (11 7/16 in deep, 24 7/8 in high, spec sheet FG8153C) and of the indoor unit (9 7/16 in × 11 in), and the clearances of 4 in behind and 24 in in front (manual 9300793025-01, §3.2.1, cases with an obstacle behind only and an obstacle in front). Floor height, railing and stand are drawn for readability, not measured.

1 · The syndicate

Before the price, the authorization

A wall unit usually needs a hole in the exterior wall for the piping and a support for the outdoor unit. In a divided co-ownership building, the exterior wall and the balcony fall under the declaration of co-ownership: it says what is private, what is common and what the by-laws of the immovable allow.

QuestionWhat the official texts sayWhat to ask the syndicate
Co-ownership: who manages the common portionsThe syndicate's object is the preservation of the immovable and the maintenance and administration of the common portions.Civil Code of Québec, art. 1039Are the exterior wall, the balcony and its slab common portions in our declaration? Is the balcony for restricted use?
Declaration of co-ownership: the by-laws of the immovableEach co-owner has free use and enjoyment of their private portion and of the common portions, provided they comply with the by-laws of the immovable and do not impair the rights of the other co-owners or the destination of the immovable.Civil Code of Québec, art. 1063Do the by-laws mention heat pumps, equipment on balconies, wall openings or the look of the façade?
Vote at the co-owners' meetingDecisions on work to alter, enlarge or improve the common portions are taken by co-owners representing three-quarters of the votes of the co-owners present or represented.Civil Code of Québec, art. 1097, para. 2Does our project go to a vote, to a written authorization from the board of directors, or under a rule already adopted for the whole building?
Wall opening: co-ownership and responsibilityThe example's manual requires a support that can hold the unit's weight and bolting the unit to its stand.FUJITSU AIRSTAGE, installation manual 9300793025-01, §3.1Who chooses where the hole and the support go? Does the syndicate require a plan, insurance or a specific contractor?

These articles are quoted to frame the questions; they do not settle your case. Your building's declaration of co-ownership applies first, and a notary or lawyer can read it with you. The texts can change: check the version in force. English wording of the Code: our translation of the French text, which prevails.

2 · The water

Two different waters, depending on the season

A wall heat pump produces water in both seasons, but not in the same place. Neighbours ask about it more than anything else, and the answer depends on your balcony.

Summer: dehumidification water

The indoor unit pulls moisture out of the room: up to 1.9 L/h for the example (spec sheet FG8153C). That water leaves through a drain hose that has to slope down. If there is no slope to a drain or outside, another solution has to be planned before installing.

Winter: water from the outdoor unit

In heating, water flows out of the outdoor unit, especially during defrost. The manual asks for a spot where that flow is not obstructed, and for measures so the water does not freeze and clog the drain.

The neighbour below

The manual forbids stacking two outdoor units where the water can freeze: water from the upper unit can form ice on the lower one. On stacked balconies, the same question applies to the slab and the balcony below.

The supplied drain pipe is not for cold weather. For reverse-cycle models, the manual says not to use the supplied drain pipe and drain cap when the outdoor temperature is 0 °C or below, because the water can freeze in the pipe. It also states that these parts are not included with the cold-region models.FUJITSU AIRSTAGE, installation manual 9300793025-01, §2.2 and §3.4
3 · The location

What the manual and one city require on a balcony

The example's manual sets clearances and safety warnings. Some cities add their own rules for balconies. Longueuil publishes a clear sheet, quoted here as an example.

Not near the edge of the balcony

The manual forbids installing the outdoor unit near the edge of a balcony: a child could climb onto it and fall.

FUJITSU AIRSTAGE, manual 9300793025-01, §3.1
One unit, surrounded by a guard

In Longueuil, in a building of four or more dwellings, only one unit per dwelling is allowed on the balcony, and a guard identical to the balcony's must surround it completely.

Ville de Longueuil, Fiche Thermopompe, November 2022
Above the snow

The manual asks to raise the unit above the expected snow depth and not to put the stand's frame under the drain port. A covered balcony helps; wind-blown snow can still get in.

FUJITSU AIRSTAGE, manual 9300793025-01, §3.1 and §3.3
In Montréal, the City says no permit is needed to install a heat pump, but the installation must comply with the borough's urban planning by-law; the allowed locations vary from one borough to another.Ville de Montréal, “Obtenir un permis pour installer une thermopompe ou un appareil de climatisation”, consulted November 10, 2026
4 · The noise

One number on the spec sheet, another in the by-law

The example's spec sheet lists 47 dB(A) for the outdoor unit, in heating and in cooling. A municipal by-law sets a limit at a specific spot, often the property line. The two numbers are not measured at the same place: you can't set one against the other to decide whether an installation complies.

dB(A)

How to read these numbers. The lower the number, the quieter the sound. The spec sheet gives neither the distance nor the method of its measurement. Longueuil's limits apply at the property line; in a condo, other rules may cover the neighbouring units.

Why this is not a compliance test. The sound that reaches a neighbour depends on distance, walls, the balcony above and where the unit sits. Only an on-site measurement, using the by-law's method, can settle it.

The manual also asks to avoid bothering neighbours with airflow, noise or vibration, and to get their approval if the unit has to be installed near them.

The example in numbers

What FUJITSU AIRSTAGE publishes for the ORION XLTH 12,000

The data that matters on a balcony, and what it changes in a condo.

Published dataORION XLTH 12,000 (example)In a condo
Outdoor unit W × H × D, weight31 7/16 × 24 7/8 × 11 7/16 in, 86 lbSpec sheet FG8153C, rev. 4/2025The space to set aside on the balcony, before clearances; the stand and the slab must carry this weight.
Outdoor unit clearances24 in in front; 4 in behind when only the back is blockedManual 9300793025-01, §3.2.1The railing in front counts as an obstacle. The manual gives other cases: blocked sides, a balcony above.
Outdoor unit base pan, water in heatingBase pan heater; water flows out of the unit in heatingSpec sheet FG8153C; manual §3.1Plan where the water goes on the slab and toward the balcony below.
Dehumidification1.9 L/h (4.0 pints/h)Spec sheet FG8153CSummer water needs a slope or another way out.
Outdoor unit sound level47 dB(A) in cooling and in heatingSpec sheet FG8153C; method and distance not statedTo weigh against where the neighbours are, not to compare directly with a municipal limit.
Advertised heating / cooling range−26 to 24 °C / −10 to 50 °CSpec sheet FG8153CA balcony exposed to wind or snow does not change the range, but it changes the upkeep.
Indoor unit W × H × D, weight38 9/16 × 11 × 9 7/16 in, 28 lbSpec sheet FG8153CThe wall hole goes behind or beside this unit, depending on the piping exit chosen.
Before the quote

Six answers to have in hand

1The declaration of co-ownership

The part that describes the balcony, the exterior wall and the by-laws of the immovable.

2The route to authorization

A vote at the meeting, written approval from the board, or a rule already adopted for the building.

3The balcony depth

From the wall to the railing, and the height under the balcony above.

4The water's path

Where summer water drains, where winter water drops, what lies under your balcony.

5The municipal by-law

Planning and noise rules of your city or borough, in the version in force.

6The neighbours

The windows and balconies closest to the planned spot for the outdoor unit.

Questions

Frequently asked questions

Do I need the syndicate's authorization to install a heat pump on my balcony?

The answer is in your declaration of co-ownership: it says whether the balcony and the exterior wall are common portions and what the by-laws allow. The Civil Code provides that decisions on work to alter, enlarge or improve the common portions are taken by co-owners representing three-quarters of the votes of the co-owners present or represented (art. 1097). Ask the syndicate which route applies to your project before signing anything.

Do I need a City permit in Montréal?

The City of Montréal says no permit is needed, but the installation must comply with the borough's urban planning by-law. Location rules vary from one borough to another, and buildings in heritage sectors go through the permit counter. Elsewhere in Québec, each city has its own rules.

Where does the outdoor unit's water go in winter?

In heating, water flows out of the outdoor unit. The example's manual asks for a spot where that flow is not obstructed and for measures so it does not freeze in the drain. The drain pipe supplied with some models is not used at 0 °C or below. On a balcony, you need to know where that water goes on the slab and whether it can reach the balcony below.

Can my unit sit above my downstairs neighbour's unit?

The example's manual forbids installing two outdoor units one above the other where the water can freeze, because water from the upper unit can form ice on the lower one. If a neighbour already has a unit under your balcony, settle it with the syndicate and the installer.

What noise level is allowed?

It depends on your municipality. In Longueuil, for example, heat-pump noise must not exceed 53 dB(A) at the property line in Vieux-Longueuil and Saint-Hubert, and 50 dB(A) in Greenfield Park. In Montréal, complaints go to 311. A unit's spec-sheet number is not measured at the same place and is not enough to conclude.

Does this guide replace legal advice?

No. It presents official texts and one example's manual to help you ask the right questions. Your declaration of co-ownership, your city's by-law and a legal professional remain the reference for your case.

Wall heat pumps are on the AirGreen site.

Once the authorization and the location are clear, the estimate visit can be planned with these answers in hand.

Sources

Documents consulted

Civil Code of Québec, art. 1039, 1063 and 1097LégisQuébec, versions in force: art. 1039 since January 10, 2020, art. 1063 since January 1, 1994, art. 1097 since March 17, 2020; consulted November 10, 2026. Laws can change.
FUJITSU AIRSTAGE, outdoor unit installation manualPart 9300793025-01, units KP 09/12, KM 09/12 and KZ 09/12/15, §2.2, 3.1 to 3.4; consulted November 10, 2026.
FUJITSU AIRSTAGE ORION XLTH, spec sheetPart FG8153C, rev. 4/2025 (English) and FG8153D (French); consulted November 10, 2026.
Ville de Longueuil, Fiche ThermopompeDirection de l'aménagement et de l'urbanisme, November 2022; consulted November 10, 2026. By-laws can change.
Ville de Montréal, heat-pump permit“Obtenir un permis pour installer une thermopompe ou un appareil de climatisation”, montreal.ca; consulted November 10, 2026.