ARCOAIRE HSA6 Premium Central Air Conditioner | 2 Tons - 24000 BTU - R410A

In stock

Arcoaire’s 2-ton HSA6 central air conditioner: an R-410A outdoor unit that communicates with the Ion control and configures itself.

Model numberHSA624GKA

2 tons24,000 BTU/h nominal size
Up to 16 SEERdepending on the matched indoor unit
67 dBAsound power (AHRI 270-08)
R-410A208/230 V · single phaseCooling onlyAvailable while supplies lastIon communicating
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHSA624GKA
ManufacturerArcoaire
Size2 tons (24,000 BTU/h)
Published combination14.5 SEER / 12.0 EER
Sound power67 dBA
Power supply208/230 V, 1 ph, 60 Hz
Max. protection25 A (time-delay fuse or breaker)

Replace your 2-ton central air conditioner with a unit that configures itself

When the old air conditioner gives out

In a cottage or a split-level home heated by an electric furnace, the 2-ton central air conditioner is often the first unit to fail. Arcoaire’s HSA624GKA takes its place outdoors. It belongs to the HSA6 series, the manufacturer’s premium single-stage line, and runs on R-410A with a single-stage scroll compressor insulated by a sound blanket.

Its nominal size is 24,000 BTU/h. For the published reference combination, with a *EN(A,D)4X31*17** coil and a TXV, Arcoaire lists 23,800 BTU/h, 14.5 SEER and 12.0 EER at 95°F. The manufacturer advertises up to 16 SEER with other matches. These SEER ratings predate the SEER2 standard: they do not compare directly with the SEER2 ratings of newer units.

A control that does the configuration work

What sets the HSA6 series apart is communication with the Ion control (SYST0101CW, sold separately). Connected to that control, the outdoor unit runs in communicating mode and configures itself. The manufacturer also provides for operation with a non-communicating thermostat, which it actually requires for cooling below 55°F (12.8°C), together with low-ambient accessories.

The rest of the system is conventional: an indoor coil, set on the electric furnace or housed in an air handler, cools the air that the blower pushes through the ductwork. Heating remains the furnace’s job. This air conditioner does not heat and, sold alone, it does not qualify for the LogisVert grant.

The HSA6 series is no longer produced by the manufacturer: this unit is available while supplies last. Arcoaire backs it with a 5-year No Hassle Replacement limited warranty and a 5-year parts limited warranty, extended by 5 years with timely registration; in Quebec, the certificate states that registration cannot be a condition.

Installation, from estimate to commissioning

AirGreen, a family business established in Montreal for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We start with a free on-site estimate to confirm that 2 tons suits the home and to choose the coil compatible with your electric furnace or air handler.

We then check the electrical panel: the unit needs a 208/230 V circuit with a time-delay fuse or breaker of 25 A maximum. Our technicians remove the old unit, set the new one, install the refrigerant lines within the lengths the manufacturer allows, then commission the system. We serve Montreal, Laval, Longueuil, the South Shore and the North Shore.

Get your quote

Ask for a free estimate: you receive a written quote for the unit and its installation, with financing available to spread out the payment.

01 · What it is for

Replacing a 2-ton central air conditioner

The HSA624GKA takes the place of a central air conditioner’s outdoor unit. Matched with a coil on your electric furnace or inside an air handler, it cools the air that then travels through the home’s ductwork.

  • Replacing a 2-ton central air conditioner at the end of its life
  • Cottages and split-level homes heated by an electric furnace
  • Systems that will use the Ion communicating control
  • Adding air conditioning to an existing air handler
Self-configuration with IonWith the Ion SYST0101CW control (sold separately), the unit runs in communicating mode and configures itself.
Published 23,800 BTU/h combinationWith a *EN(A,D)4X31*17** coil and a TXV, Arcoaire publishes 14.5 SEER and 12.0 EER at 95°F.
Copper and aluminum coilCopper tubes and aluminum fins, post-painted black.
Compatible with
*EN(A,D)4X31*17**
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerArcoaire
SeriesHSA6, single stage, communicating (Ion)
TypeCentral air conditioner outdoor unit (cooling only)
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-410A, factory charged
Factory charge6.00 lb (2.72 kg), for 15 ft (4.6 m) of 3/8 in liquid line
CompressorScroll, single stage, with sound blanket
Advertised efficiencyUp to 16 SEER depending on the matched indoor unit (SEER rating that predates SEER2)
Published reference combination14.5 SEER / 12.0 EER with *EN(A,D)4X31*17** coil, 23,800 BTU/h (TXV, 95°F)
Sound power67 dBA (AHRI 270-08)
Power supply208/230 V, single phase, 60 Hz (197 to 253 V operating)
Minimum circuit ampacity17.5 A
Max. time-delay fuse or breaker25 A
Compressor (RLA / LRA)13.5 A / 58.3 A
Fan motor (FLA)0.70 A
Vapor line connection3/4 in (ID)
Liquid line connection3/8 in (ID)
Outdoor coilCopper tubes, aluminum fins painted black
Communicating controlIon SYST0101CW (sold separately)
Dimensions (H x W x D)28-9/16 x 31-3/16 x 31-3/16 in (726 x 792 x 792 mm)
Weight (shipping / operating)212 / 176 lb (96 / 80 kg)
Manufacturer’s limited warrantyNo Hassle Replacement: 5 years. Parts (compressor and coil included): 5 years, plus 5 years with timely registration
Model numberHSA624GKA
03 · Before installing

What to know before installing

  • Available while supplies last: the HSA6 series is no longer produced by the manufacturer.
  • Cooling only. Sold alone, the unit does not qualify for the LogisVert grant.
  • The indoor coil and the Ion control are not included.
  • 208/230 V single-phase circuit: 17.5 A minimum circuit ampacity, 25 A maximum time-delay fuse or breaker.
  • TXV required beyond 20 ft (6.1 m) of vertical separation or 50 ft (15.2 m) of total length; long-line accessories beyond 80 ft (24.4 m).
  • Below 55°F (12.8°C), cooling requires low-ambient accessories and a non-communicating thermostat.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Central air conditioners
See all
Same brand
ARCOAIRE
See all
06 · Questions

Frequently asked questions

Why does the published combination give 23,800 BTU/h and not 24,000?

The 24,000 BTU/h is the 2-ton nominal size. The 23,800 BTU/h figure is the capacity measured for the reference combination with a *EN(A,D)4X31*17** coil and a TXV, at 95°F.

Will my current thermostat work?

Arcoaire recommends the Ion SYST0101CW communicating control, sold separately, for self-configuring operation. The manufacturer also provides for a non-communicating thermostat, required in particular for cooling below 55°F (12.8°C). We check your thermostat during the estimate.

What electrical circuit is needed?

A 208/230 V single-phase circuit, with a 17.5 A minimum circuit ampacity and a 25 A maximum time-delay fuse or breaker.

Does it qualify for a grant?

No. A cooling-only air conditioner sold alone does not qualify for Hydro-Québec’s LogisVert grant.

What warranty does Arcoaire provide?

A 5-year No Hassle Replacement limited warranty and a 5-year parts limited warranty, compressor and coil included, plus 5 years with timely registration. In Quebec, the certificate states that registration cannot be a condition. Labour is not covered by the manufacturer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your 2-ton Arcoaire central air conditioner, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.