Arcoaire’s 3.5-ton HSA6 central air conditioner: a single-stage R-410A outdoor unit that communicates with the Ion control.
Model numberHSA642GKA
514 316-2973 · sales@airgreen.ca
Quick facts
A 3.5-ton central air conditioner that reaches its nominal capacity in its published combination
The HSA642GKA in a few words
The HSA642GKA is the outdoor unit of Arcoaire’s 3.5-ton (42,000 BTU/h) central air conditioner in the HSA6 series, the manufacturer’s premium single-stage line. It serves larger homes whose ductwork reaches several floors and many rooms. It runs on R-410A with a single-stage scroll compressor wrapped in a sound blanket, and its outdoor coil is made of copper tubes and aluminum fins painted black.
Worth noting: the reference combination Arcoaire publishes, with a *EN(A,D)4X43*24** coil and a TXV, reaches 42,000 BTU/h at 95°F, with 14.5 SEER and 12.0 EER. The manufacturer advertises up to 16 SEER depending on the matched indoor unit. These SEER ratings predate the SEER2 standard.
The electrical panel, the first thing to check
In an electrically heated home, the panel already supplies the furnace, the water heater and the range. The HSA642GKA needs a 208/230 V single-phase circuit with a 23.4 A minimum circuit ampacity and a time-delay fuse or breaker of 40 A maximum. It is the first thing we look at during the estimate: better to know before ordering the unit.
Outdoors: a tall cabinet on a compact base
The cabinet stands 40-1/8 in high on a 35 x 35 in base and weighs 297 lb for shipping. Clear access for handling is therefore needed. Its published sound power is 68 dBA. To cool below 55°F (12.8°C), the manufacturer requires low-ambient accessories and a non-communicating thermostat; otherwise, the Ion communicating control (SYST0101CW, sold separately) allows self-configuring operation.
Remember that the unit is cooling only and that, sold alone, it does not qualify for the LogisVert grant. It is available while supplies last, as the HSA6 series is no longer produced. Arcoaire provides a 5-year No Hassle Replacement limited warranty and a 5-year parts limited warranty, plus 5 years with timely registration, a condition that, according to the certificate, cannot apply in Quebec.
What AirGreen does
AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We do the free on-site estimate, prepare a written quote, then install the outdoor unit, the coil matched with your electric furnace or air handler, the refrigerant lines and the electrical connection, before commissioning. We work in Montreal, Laval, Longueuil, the South Shore and the North Shore.
Tell us about your home and your electrical panel: the estimate is free, and financing is available.
Central air conditioning for large living spaces
The HSA642GKA is the outdoor unit of a 3.5-ton central air conditioner. It works with a coil set on an electric furnace or housed in an air handler, and the cooled air is distributed through the ductwork.
- Larger single-family homes with extensive ductwork
- Replacing a 3.5-ton central air conditioner
- Homes heated by an electric furnace or an air handler
- Systems run by the Ion communicating control
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Available while supplies last: the HSA6 series is no longer produced by the manufacturer.
- Cooling only. Sold alone, it does not qualify for the LogisVert grant.
- 208/230 V single-phase circuit: 23.4 A minimum circuit ampacity, 40 A maximum time-delay fuse or breaker. Check your panel’s capacity.
- Cabinet 40-1/8 in high on a 35 x 35 in base, 297 lb shipping weight: plan access for handling.
- Indoor coil not included. TXV required beyond 20 ft (6.1 m) of vertical separation or 50 ft (15.2 m) of total length.
- Below 55°F (12.8°C), cooling requires low-ambient accessories and a non-communicating thermostat.
Manufacturer documents
Explore the range
Central air conditionersSee allSame brand
ARCOAIRESee all
Frequently asked questions
Can my electrical panel take this unit?
It needs a 208/230 V single-phase circuit with a 23.4 A minimum circuit ampacity, protected by a time-delay fuse or breaker of 40 A maximum. In an electrically heated home, we check the panel’s capacity during the estimate, before confirming the quote.
What actual capacity does it deliver?
It depends on the coil. For the published combination with a *EN(A,D)4X43*24** coil and a TXV, Arcoaire lists 42,000 BTU/h at 95°F, with 14.5 SEER and 12.0 EER. These ratings predate the SEER2 standard.
What are its dimensions?
The cabinet measures 40-1/8 x 35 x 35 in (H x W x D), or 1019 x 889 x 889 mm. It weighs 297 lb for shipping and 253 lb in operation.
Does this air conditioner qualify for the LogisVert grant?
No. It is cooling only and, sold alone, it does not qualify for Hydro-Québec’s LogisVert grant.
How does Arcoaire’s warranty work?
Arcoaire provides a 5-year No Hassle Replacement limited warranty and a 5-year parts limited warranty, compressor and coil included, plus 5 years with timely registration. The certificate states that in Quebec, registration cannot be a condition. Labour is not part of the manufacturer’s warranty.
A 3.5-ton Arcoaire central air conditioner, installed by AirGreen