Four tons to get a very large home through the heat waves
The largest size in the HSA6 series
When the humidex climbs and the afternoon sun hits the big windows, a very large home needs a central air conditioner that can keep up. The HSA648GKA is the 4-ton (48,000 BTU/h) outdoor unit of the HSA6 series, Arcoaire’s premium single-stage line. It runs on R-410A, with a single-stage scroll compressor wrapped in a sound blanket.
The figure that stands out on its spec sheet is the EER, the efficiency measured at 95°F. For the reference combination with a *EN(A,D)4X61*24** coil and a TXV, Arcoaire publishes 46,500 BTU/h, 14.5 SEER and 12.5 EER. The manufacturer advertises up to 16 SEER depending on the matched indoor unit. All these ratings predate the SEER2 standard.
What the installation requires
A unit of this size is not installed lightly. Indoors, the coil and the air handler or electric furnace must be able to deliver the airflow of a 4-ton system. Outdoors, the 40-1/8 x 35 x 35 in cabinet (H x W x D) weighs 340 lb for shipping; its published sound power is 70 dBA. On the electrical side, a 208/230 V single-phase circuit is needed, with a 26.1 A minimum circuit ampacity and a time-delay fuse or breaker of 40 A maximum.
The refrigerant lines connect at 3/8 in (liquid) and 7/8 in (vapor). The 13.00 lb factory charge covers 15 ft of liquid line; beyond 50 ft (15.2 m) of total length or 20 ft (6.1 m) of vertical separation, the manufacturer requires a TXV.
How AirGreen handles it
AirGreen is a family business established in Montreal for more than fifteen years. With our RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, we carry out the whole project: free on-site estimate, check of the air handler or furnace and of the panel, written quote, setting of the outdoor unit and coil, refrigerant lines, electrical connection and commissioning. The Ion communicating control (SYST0101CW, sold separately) can complete the system for self-configuring operation.
We work on the South Shore, in Longueuil, Montreal, Laval and on the North Shore.
Good to know
The HSA648GKA is cooling only and, sold alone, it does not qualify for the LogisVert grant. As the HSA6 series is no longer produced, it is available while supplies last. Arcoaire provides a 5-year No Hassle Replacement limited warranty and a 5-year parts limited warranty, plus 5 years with timely registration; according to the certificate, registration cannot be a condition in Quebec.
Ask for your free on-site estimate and receive a written quote. Financing is available for this project.
Cooling a very large home through heat waves
The HSA648GKA is the outdoor unit of a 4-ton central air conditioner. It is matched with a coil set on an electric furnace or housed in an air handler able to move the airflow this size requires.
- Very large homes whose ductwork serves several floors
- Replacing a 4-ton central air conditioner
- Homes with large windows or strong afternoon sun
- Systems run by the Ion communicating control
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Available while supplies last: the HSA6 series is no longer produced by the manufacturer.
- Cooling only. Sold alone, the unit does not qualify for the LogisVert grant.
- 208/230 V single-phase circuit: 26.1 A minimum circuit ampacity, 40 A maximum time-delay fuse or breaker.
- 40-1/8 x 35 x 35 in cabinet (H x W x D), 340 lb shipping and 295 lb operating weight: plan clear access and suitable handling equipment.
- The indoor coil and its air handler or electric furnace must suit a 4-ton system; they are not included.
- TXV required beyond 20 ft (6.1 m) of vertical separation or 50 ft (15.2 m) of total length. Below 55°F (12.8°C): low-ambient accessories and a non-communicating thermostat.
Manufacturer documents
Explore the range
Central air conditionersSee allSame brand
ARCOAIRESee all
Frequently asked questions
What does 12.5 EER mean?
EER measures cooling efficiency at an outdoor temperature of 95°F, the temperature of a heat-wave day. Arcoaire publishes 12.5 EER for this air conditioner’s combination with a *EN(A,D)4X61*24** coil and a TXV. It is a rating that predates the SEER2 (EER2) standard.
What electrical circuit is needed?
A 208/230 V single-phase circuit, with a 26.1 A minimum circuit ampacity and a time-delay fuse or breaker of 40 A maximum.
Is my current air handler suitable?
It must be able to take a coil suited to 4 tons and deliver the matching airflow. We check your electric furnace or air handler during the estimate, before proposing the coil.
Does it qualify for the LogisVert grant?
No. It is cooling only and, sold alone, it does not qualify for Hydro-Québec’s LogisVert grant.
What warranty does Arcoaire provide?
A 5-year No Hassle Replacement limited warranty and a 5-year parts limited warranty, compressor and coil included, plus 5 years with timely registration. The certificate states that in Quebec, registration cannot be a condition. Labour is not covered by the manufacturer.