GENERAL AIRSTAGE Electric Heat Kit for AMUH12-24 Air Handler

In stock

The genuine electric heater that fits inside the AIRSTAGE AMUH multi-position air handler (GENERAL or Fujitsu) and takes over in deep cold.

AirGreen codeAG-AC-00101

2 to 8 kWsix kits
1 or 2 stagesdepending on the model
208/240 Vpower supply
AMUH air handlerGenuine part
Modèle
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-00101
BrandGENERAL (formerly Fujitsu General)
Part no.UTZ-EU02MSA to UTZ-EU08MSB2
ForAMUH12KUAS, AMUH18KUAS, AMUH24KUAS air handlers
Power supply208/240 V

GENERAL AIRSTAGE UTZ-EU electric heater kits are, under the GENERAL label, the same part as the Fujitsu AIRSTAGE version; for as long as the transition lasts, both names share the shelves. The name GENERAL Inc. replaced Fujitsu General Limited on January 1, 2026, without touching the manufacturer, the factories or the model numbers. The element is housed in the cabinet of the AMUH multi-position air handler belonging to an AIRSTAGE central heat pump, GENERAL or Fujitsu brand. It heats the air that is already flowing through the air handler and carries the load whenever the heat pump defrosts or the cold gets extreme. The six kits grouped here are for the small cabinet, the one used by the AMUH12KUAS, AMUH18KUAS and AMUH24KUAS air handlers.

No universal kit: the air handler decides

The manufacturer’s submittal sheet spells out, air handler by air handler, which outputs are allowed. Every model runs on 208/240 V. A model number ending in MSA means one heating stage; MSB2 means two, with the second stage joining in only as demand climbs.

Which kit for which air handler

  • AMUH12KUAS: 2 kW in one stage with the UTZ-EU02MSA, or 4 kW in two stages with the UTZ-EU04MSB2
  • AMUH18KUAS: 3 kW in one stage with the UTZ-EU03MSA, or 6 kW in two stages with the UTZ-EU06MSB2
  • AMUH24KUAS: 2 kW with the UTZ-EU02MSA, 4 kW in one stage with the UTZ-EU04MSA, or 8 kW in two stages with the UTZ-EU08MSB2

What to check before ordering

It all begins with the air handler’s nameplate: copy the model number from it in full. The right output also depends on the home’s heating load and on what your electrical service can deliver; it is the nameplate, along with the Québec Construction Code, that is used to size the circuit. The AMUH30 to AMUH48 air handlers, built in a medium cabinet, call for a different kit series, shown on its own page.

A kit fitted and wired by AirGreen

As an authorized GENERAL and Fujitsu AIRSTAGE dealer, AirGreen fits the kit in the air handler and then wires it, with the power cut and following the manufacturer’s instructions, for customers in Montreal, Laval, Longueuil, the North Shore and the South Shore, under RBQ licence 5645-9605-01. To find out whether the kit you need is available or to get a quote, reach us at 514 316-2973 or sales@airgreen.ca, stating the air handler model, the output you want and how many kits you need.

01 · What it is for

Backup heat built into the air handler

The kit installs in the AMUH cabinet and heats the air already moving through your ducts.

  • Backup heat for a GENERAL or Fujitsu AIRSTAGE central heat pump with an AMUH air handler
  • Heat during defrost cycles and extreme cold
  • Replacing an original kit on an existing AMUH air handler
  • New builds where the air handler serves a whole home through ductwork
Matched to the air handlerThe manufacturer pairs each kit with specific air handlers: 12, 18 or 24,000 BTU.
1 or 2 stagesMSB2 models heat in two stages, MSA models in one.
Genuine partDesigned by the manufacturer for the small cabinet of its AMUH air handlers.
Compatible with
AMUH12KUASAMUH18KUASAMUH24KUAS
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

6 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModèleCapacityHeating stagesPower supplyAir handlers listed by the manufacturerPart no.AirGreen code
2 kW, 1 étage – UTZ-EU02MSA2 kW1208/240 VAMUH12KUAS, AMUH24KUASUTZ-EU02MSAAG-AC-00101
3 kW, 1 étage – UTZ-EU03MSA3 kW1208/240 VAMUH18KUASUTZ-EU03MSAAG-AC-00102
4 kW, 1 étage – UTZ-EU04MSA4 kW1208/240 VAMUH24KUASUTZ-EU04MSAAG-AC-00103
4 kW, 2 étages – UTZ-EU04MSB24 kW2208/240 VAMUH12KUASUTZ-EU04MSB2AG-AC-00104
6 kW, 2 étages – UTZ-EU06MSB26 kW2208/240 VAMUH18KUASUTZ-EU06MSB2AG-AC-00105
8 kW, 2 étages – UTZ-EU08MSB28 kW2208/240 VAMUH24KUASUTZ-EU08MSB2AG-AC-00106

The manufacturer lists each kit for specific air handlers: check the “Air handlers listed by the manufacturer” row of the model you pick.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandGENERAL (formerly Fujitsu General)
TypeElectric heater kit for multi-position air handler
Capacities2, 3, 4, 6 and 8 kW
Stages1 (MSA models) or 2 (MSB2 models)
Power supply208/240 V
Air handlersAMUH12KUAS, AMUH18KUAS, AMUH24KUAS (small cabinet)
System refrigerantR-32
Capacity2 kW
Heating stages1
Power supply208/240 V
Air handlers listed by the manufacturerAMUH12KUAS, AMUH24KUAS
Part no.UTZ-EU02MSA
AirGreen codeAG-AC-00101
04 · Before installing

What to know before installing

  • Read the full air handler model number on its nameplate before choosing the capacity.
  • The manufacturer lists the compatible kits for each air handler on its submittal sheet.
  • The electrical circuit must be sized from the nameplate and the Québec electrical code.
  • Wiring is done with the power off, by a licensed electrician or refrigeration technician.
05 · Goes with

You may also need

Same category
Original parts
See all
06 · Questions

Frequently asked questions

Which kit fits my air handler?

The manufacturer pairs each kit with specific air handlers. For example, UTZ-EU03MSA and UTZ-EU06MSB2 are listed for the AMUH18KUAS. Send us your air handler model number and we confirm before ordering.

What is the difference between 1 and 2 stages?

A 2-stage kit heats in two steps: the first is often enough, the second comes on when demand rises. A 1-stage kit works as a single block.

Do these kits fit an AMUH30 to 48?

No. The AMUH30KUAS, AMUH36KUAS and AMUH48KUAS use the UTZ-EU…MMA and MMB2 series, on a separate page.

Can you install it?

Yes. We install the kit in the air handler and wire it, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Genuine backup heat for your GENERAL or Fujitsu AIRSTAGE air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.