GENERAL AIRSTAGE Electric Heater Kit for AMUH30-48 Air Handler

In stock

Genuine electric heat for AIRSTAGE AMUH air handlers (GENERAL or Fujitsu) from 30,000 to 48,000 BTU, in one or two stages.

AirGreen codeAG-AC-00201

3 to 16 kWseven kits
1 or 2 stagesdepending on the model
208/240 Vpower supply
AMUH air handlerGenuine part
Modèle
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-AC-00201
BrandGENERAL (formerly Fujitsu General)
Part no.UTZ-EU03MMA to UTZ-EU16MMB2
ForAMUH30KUAS, AMUH36KUAS, AMUH48KUAS air handlers
Power supply208/240 V

Intended for the medium cabinet, GENERAL AIRSTAGE UTZ-EU…MMA and MMB2 electric heater kits take their place inside the AMUH30KUAS, AMUH36KUAS and AMUH48KUAS multi-position air handlers. Whether the box reads GENERAL or Fujitsu AIRSTAGE, the element inside is identical. GENERAL Inc. has been the new name, since January 1, 2026, of Fujitsu General Limited, acquired by Paloma Rheem Holdings; nothing has changed in the factories or in the model numbers. These kits have one clear job: to provide the backup heat for a 2.5 to 4-ton AIRSTAGE central heat pump (GENERAL or Fujitsu) while it defrosts, or when the cold asks more of it than it can give.

From 3 to 16 kW, in seven kits

On -25 °C mornings, when the house is heated through ducts, electric backup becomes decisive. For this cabinet, the manufacturer offers seven 208/240 V kits: the MMA models work on a single stage, while the MMB2 models split the heat in two and bring in the second stage only if demand requires it.

The pairings given by the manufacturer

  • AMUH30KUAS: 3 kW with the UTZ-EU03MMA, 5 kW with the UTZ-EU05MMA, or 10 kW in two stages with the UTZ-EU10MMB2
  • AMUH36KUAS: 3 kW with the UTZ-EU03MMA, 6 kW with the UTZ-EU06MMA, or 12 kW in two stages with the UTZ-EU12MMB2
  • AMUH48KUAS: 5 kW with the UTZ-EU05MMA, 8 kW with the UTZ-EU08MMA, or 16 kW in two stages with the UTZ-EU16MMB2

Aiming for the right output

The biggest kit is not necessarily the right one: it calls for a heftier circuit and, in an existing house, it may ask for more than the electrical service is able to supply. Three facts guide the choice: the building’s heating load, what the heat pump still produces at low temperature and the electrical service you have. Finally, the circuit size is worked out from the nameplate, in compliance with the Québec Construction Code.

Backup heat installed with your central heat pump

AirGreen fits these kits when installing your GENERAL or Fujitsu AIRSTAGE central heat pump, or during its maintenance, in Montreal, in Laval, in Longueuil, on the North Shore and on the South Shore; this work is done under our RBQ licence 5645-9605-01. Call us at 514 316-2973 or send your air handler model, the output you are aiming for and the quantity to sales@airgreen.ca: we will confirm availability and send you a quote.

01 · What it is for

Backup heat for the larger AMUH air handlers

On a 2.5 to 4-ton central heat pump, the kit covers the heat the heat pump cannot supply in deep cold.

  • Backup heat for a 30,000 to 48,000 BTU GENERAL or Fujitsu AIRSTAGE central heat pump
  • Houses and large units heated through ductwork
  • Heat during defrost cycles
  • Replacing an original kit on a medium-cabinet AMUH air handler
Up to 16 kWUTZ-EU16MMB2 is the largest kit the manufacturer lists for the AMUH48KUAS.
Two stagesMMB2 models split their output into two steps.
Medium cabinetDesigned for the cabinet shared by the AMUH30, 36 and 48.
Compatible with
AMUH30KUASAMUH36KUASAMUH48KUAS
Per the manufacturer. Send us your unit’s model number and we confirm before ordering.
02 · Sizes

7 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

ModèleCapacityHeating stagesPower supplyAir handlers listed by the manufacturerPart no.AirGreen code
3 kW, 1 étage – UTZ-EU03MMA3 kW1208/240 VAMUH30KUAS, AMUH36KUASUTZ-EU03MMAAG-AC-00201
5 kW, 1 étage – UTZ-EU05MMA5 kW1208/240 VAMUH30KUAS, AMUH48KUASUTZ-EU05MMAAG-AC-00202
6 kW, 1 étage – UTZ-EU06MMA6 kW1208/240 VAMUH36KUASUTZ-EU06MMAAG-AC-00203
8 kW, 1 étage – UTZ-EU08MMA8 kW1208/240 VAMUH48KUASUTZ-EU08MMAAG-AC-00204
10 kW, 2 étages – UTZ-EU10MMB210 kW2208/240 VAMUH30KUASUTZ-EU10MMB2AG-AC-00205
12 kW, 2 étages – UTZ-EU12MMB212 kW2208/240 VAMUH36KUASUTZ-EU12MMB2AG-AC-00206
16 kW, 2 étages – UTZ-EU16MMB216 kW2208/240 VAMUH48KUASUTZ-EU16MMB2AG-AC-00207

The manufacturer lists each kit for specific air handlers: check the “Air handlers listed by the manufacturer” row of the model you pick.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

BrandGENERAL (formerly Fujitsu General)
TypeElectric heater kit for multi-position air handler
Capacities3, 5, 6, 8, 10, 12 and 16 kW
Stages1 (MMA models) or 2 (MMB2 models)
Power supply208/240 V
Air handlersAMUH30KUAS, AMUH36KUAS, AMUH48KUAS (medium cabinet)
System refrigerantR-32
Capacity3 kW
Heating stages1
Power supply208/240 V
Air handlers listed by the manufacturerAMUH30KUAS, AMUH36KUAS
Part no.UTZ-EU03MMA
AirGreen codeAG-AC-00201
04 · Before installing

What to know before installing

  • The manufacturer pairs each kit with specific air handlers: check the match before ordering.
  • Capacity is chosen from the building’s heating load and the electrical service.
  • The circuit must be sized from the nameplate and the Québec electrical code.
  • Install with the power off, by a licensed electrician or refrigeration technician.
05 · Goes with

You may also need

Same category
Original parts
See all
06 · Questions

Frequently asked questions

Which kit for an AMUH36KUAS?

The manufacturer lists three kits for it: UTZ-EU03MMA (3 kW), UTZ-EU06MMA (6 kW) and UTZ-EU12MMB2 (12 kW, 2 stages). We help you choose from the home’s heating load.

Can I put a 16 kW kit on an AMUH30?

The manufacturer lists UTZ-EU16MMB2 for the AMUH48KUAS only. For the AMUH30KUAS, the listed kits go up to UTZ-EU10MMB2.

Do these kits fit an AMUH12 to 24?

No. The small cabinet uses the UTZ-EU…MSA and MSB2 series, on a separate page.

Can you install it?

Yes. We fit it in the air handler and wire it, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

The right heater kit for your AMUH air handler

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.