GENERAL AIRSTAGE Electric Heater Kit for AMUH30-48 Air Handler
Genuine electric heat for AIRSTAGE AMUH air handlers (GENERAL or Fujitsu) from 30,000 to 48,000 BTU, in one or two stages.
AirGreen codeAG-AC-00201
514 316-2973 · sales@airgreen.ca
Quick facts
Intended for the medium cabinet, GENERAL AIRSTAGE UTZ-EU…MMA and MMB2 electric heater kits take their place inside the AMUH30KUAS, AMUH36KUAS and AMUH48KUAS multi-position air handlers. Whether the box reads GENERAL or Fujitsu AIRSTAGE, the element inside is identical. GENERAL Inc. has been the new name, since January 1, 2026, of Fujitsu General Limited, acquired by Paloma Rheem Holdings; nothing has changed in the factories or in the model numbers. These kits have one clear job: to provide the backup heat for a 2.5 to 4-ton AIRSTAGE central heat pump (GENERAL or Fujitsu) while it defrosts, or when the cold asks more of it than it can give.
From 3 to 16 kW, in seven kits
On -25 °C mornings, when the house is heated through ducts, electric backup becomes decisive. For this cabinet, the manufacturer offers seven 208/240 V kits: the MMA models work on a single stage, while the MMB2 models split the heat in two and bring in the second stage only if demand requires it.
The pairings given by the manufacturer
- AMUH30KUAS: 3 kW with the UTZ-EU03MMA, 5 kW with the UTZ-EU05MMA, or 10 kW in two stages with the UTZ-EU10MMB2
- AMUH36KUAS: 3 kW with the UTZ-EU03MMA, 6 kW with the UTZ-EU06MMA, or 12 kW in two stages with the UTZ-EU12MMB2
- AMUH48KUAS: 5 kW with the UTZ-EU05MMA, 8 kW with the UTZ-EU08MMA, or 16 kW in two stages with the UTZ-EU16MMB2
Aiming for the right output
The biggest kit is not necessarily the right one: it calls for a heftier circuit and, in an existing house, it may ask for more than the electrical service is able to supply. Three facts guide the choice: the building’s heating load, what the heat pump still produces at low temperature and the electrical service you have. Finally, the circuit size is worked out from the nameplate, in compliance with the Québec Construction Code.
Backup heat installed with your central heat pump
AirGreen fits these kits when installing your GENERAL or Fujitsu AIRSTAGE central heat pump, or during its maintenance, in Montreal, in Laval, in Longueuil, on the North Shore and on the South Shore; this work is done under our RBQ licence 5645-9605-01. Call us at 514 316-2973 or send your air handler model, the output you are aiming for and the quantity to sales@airgreen.ca: we will confirm availability and send you a quote.
Backup heat for the larger AMUH air handlers
On a 2.5 to 4-ton central heat pump, the kit covers the heat the heat pump cannot supply in deep cold.
- Backup heat for a 30,000 to 48,000 BTU GENERAL or Fujitsu AIRSTAGE central heat pump
- Houses and large units heated through ductwork
- Heat during defrost cycles
- Replacing an original kit on a medium-cabinet AMUH air handler
7 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Modèle | Capacity | Heating stages | Power supply | Air handlers listed by the manufacturer | Part no. | AirGreen code |
|---|---|---|---|---|---|---|
| 3 kW, 1 étage – UTZ-EU03MMA | 3 kW | 1 | 208/240 V | AMUH30KUAS, AMUH36KUAS | UTZ-EU03MMA | AG-AC-00201 |
| 5 kW, 1 étage – UTZ-EU05MMA | 5 kW | 1 | 208/240 V | AMUH30KUAS, AMUH48KUAS | UTZ-EU05MMA | AG-AC-00202 |
| 6 kW, 1 étage – UTZ-EU06MMA | 6 kW | 1 | 208/240 V | AMUH36KUAS | UTZ-EU06MMA | AG-AC-00203 |
| 8 kW, 1 étage – UTZ-EU08MMA | 8 kW | 1 | 208/240 V | AMUH48KUAS | UTZ-EU08MMA | AG-AC-00204 |
| 10 kW, 2 étages – UTZ-EU10MMB2 | 10 kW | 2 | 208/240 V | AMUH30KUAS | UTZ-EU10MMB2 | AG-AC-00205 |
| 12 kW, 2 étages – UTZ-EU12MMB2 | 12 kW | 2 | 208/240 V | AMUH36KUAS | UTZ-EU12MMB2 | AG-AC-00206 |
| 16 kW, 2 étages – UTZ-EU16MMB2 | 16 kW | 2 | 208/240 V | AMUH48KUAS | UTZ-EU16MMB2 | AG-AC-00207 |
The manufacturer lists each kit for specific air handlers: check the “Air handlers listed by the manufacturer” row of the model you pick.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- The manufacturer pairs each kit with specific air handlers: check the match before ordering.
- Capacity is chosen from the building’s heating load and the electrical service.
- The circuit must be sized from the nameplate and the Québec electrical code.
- Install with the power off, by a licensed electrician or refrigeration technician.
You may also need
GENERAL AIRSTAGE Downflow Conversion Kit for AMUH Air Handler
GENERAL AIRSTAGE Filter Base for AMUH Air Handler
GENERAL AIRSTAGE Remote Temperature Sensor – UTY-XSZXZ1
GENERAL AIRSTAGE KAGAMI Wired Controller – UTY-RVRU
GENERAL AIRSTAGE 24 V Thermostat Interface – UTY-TTRXZ1
Copper Electrical Wire
Fujitsu Leak Detection System Accessory – UTYSGZU
GENERAL AIRSTAGE Leak Detection System Accessory – UTYSGZUOriginal partsSee all
Frequently asked questions
Which kit for an AMUH36KUAS?
The manufacturer lists three kits for it: UTZ-EU03MMA (3 kW), UTZ-EU06MMA (6 kW) and UTZ-EU12MMB2 (12 kW, 2 stages). We help you choose from the home’s heating load.
Can I put a 16 kW kit on an AMUH30?
The manufacturer lists UTZ-EU16MMB2 for the AMUH48KUAS only. For the AMUH30KUAS, the listed kits go up to UTZ-EU10MMB2.
Do these kits fit an AMUH12 to 24?
No. The small cabinet uses the UTZ-EU…MSA and MSB2 series, on a separate page.
Can you install it?
Yes. We fit it in the air handler and wire it, everywhere in Greater Montréal.
The right heater kit for your AMUH air handler
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.