Outdoor Disconnect Switch for Heat Pump

In stock

The disconnect switch installed near the outdoor unit to shut off the heat pump’s power safely.

AirGreen codeAG-EL-00102

Outdoornear the outdoor unit
Local shut-offfor maintenance and repair
1 or 10single or pack of 10
ElectricalSafety
Format
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-EL-00102
TypeOutdoor disconnect switch
ForHeat pump and air conditioner outdoor units
FormatsSingle or pack of 10

The outdoor disconnect switch, often just called a disconnect, is the switch installed near the outdoor unit of a heat pump or air conditioner. It lets you cut power to the unit on the spot, during maintenance or a repair, without going to the electrical panel. It is offered individually or in a pack of 10.

Why a disconnect near the outdoor unit

When a technician opens the outdoor unit, they have to be certain nobody will turn the power back on while they work. The electrical panel is often in the basement, far from the unit. The disconnect, installed within sight of the unit, settles the matter: you shut it off, you check, you work. A means of disconnection near the unit is part of a compliant electrical installation; your electrician checks its location according to the Québec Construction Code, Chapter V – Electricity.

Choosing and placing the disconnect

  • The rating is determined from the outdoor unit’s nameplate.
  • Install it near the unit, in a spot that is accessible at all times, out of the way of snow sliding off the roof.
  • The pack of 10 is for installers who put in several units.

A job for an electrician

Electrical connection is reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electricity), and is a member of the CMEQ. Our technicians install and connect the disconnect as part of installing your heat pump.

Installed by AirGreen across Greater Montréal

We install and connect the disconnect on every heat pump installation in Montréal, Laval, Longueuil, the South Shore and the North Shore. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the format and quantity.

01 · What it is for

Shutting off power right next to the equipment

A technician working on the outdoor unit must be able to cut the power on the spot, without going to the panel.

  • Power to outdoor units of wall-mount and multi-zone heat pumps
  • Central heat pumps and central air conditioners
  • Replacing a rusted or damaged disconnect
  • Job sites with several installations (pack of 10)
SafetyPower is cut within sight of the unit during maintenance.
Electrical requirementA disconnecting means near the outdoor unit is part of a compliant installation.
Two formatsSingle or a pack of 10 for installers.
02 · Sizes

2 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

FormatAirGreen code
EachAG-EL-00101
Pack of 10AG-EL-00102

Single, or a pack of 10 disconnects.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

TypeOutdoor disconnect switch
UsePower to a heat pump or air conditioner outdoor unit
Available formatsSingle, pack of 10
AirGreen codeAG-EL-00102
04 · Before installing

What to know before installing

  • Size the disconnect from the outdoor unit’s nameplate.
  • The connection must be made by an electrical contractor.
  • Install it near the outdoor unit, where it is accessible and out of the way of snow sliding off the roof.
  • Your electrician checks the location required by the Québec Construction Code, Chapter V – Electricity.
05 · Goes with

You may also need

Job kitEverything for a wall-mount heat pump install
Line sets, brackets, cover, drain, disconnect and cable on one page.
See the kit
Same category
Electrical
See all
06 · Questions

Frequently asked questions

Is a disconnect mandatory?

A heat pump must be able to be shut off near the outdoor unit for maintenance. Your electrician applies the requirements of the Québec Construction Code, Chapter V – Electricity, for the installation.

Which rating do I need?

The one that matches the outdoor unit’s electrical values, printed on its nameplate. We determine it from your exact equipment model.

Can I install it myself?

No. Electrical connection work is reserved for an electrical contractor holding an RBQ licence.

Can you install it?

Yes. AirGreen holds RBQ subclass 16 (electrical): our technicians install and connect the disconnect when they install your heat pump.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A safe shut-off right next to your heat pump

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.