DURASTAR DRBEF2417SEANMC Evaporator N-Coil | 2 Tons

In stock

The Durastar DRBEF2417SEANMC 2-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF2417SEANMC

2 tons24,000 BTU/h nominal
17-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF2417SEANMC
ManufacturerDurastar
Size2 tons
Width17-1/2 in
RefrigerantR-454B
MeteringEEV

DRBEF2417SEANMC: the narrow 2-ton Durastar coil for compact furnaces

Some furnaces simply don't have room for a big cabinet. The DRBEF2417SEANMC was designed for them: a Durastar N-shaped evaporator coil that ships with its cabinet, measures 17-1/2 in wide and runs on R-454B refrigerant. Its nominal size is 2 tons, or 24,000 BTU/h. At AirGreen, we install it for homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore who want to add air conditioning, or a central heat pump, without redoing their whole heating system.

Why width matters so much here

In the DRBEF series, this model is one of only three whose spec sheet publishes the cabinet width: 17-1/2 in. That is the most useful piece of information for a duplex or a small bungalow, because the coil sits on the furnace outlet, and the two parts have to meet without improvising.

If the furnace is wider or narrower than the cabinet, it is not a disaster. We measure the unit on site and, if needed, build an insulated transition. But it is better to know before the order, which is why we always make a visit first.

The N-coil, explained without jargon

Picture the coil's tubing folded in a zigzag, with three faces following one another, a bit like the letter N. This shape fits in a cabinet that is shorter than an A-coil. When the space above the furnace is tight, for example under a basement beam, the N shape is often the only one that fits.

The unit is multi-position: upflow, downflow, or horizontal left or right. That gives us room to orient it to suit the layout of your mechanical room rather than the other way around.

What the coil actually does in your home

The coil is the part where the cooling is made. The outdoor unit sends refrigerant through its tubes, your home's air passes across them, and the heat in that air is absorbed. Water that condenses on the cold surfaces drops into the pan, then leaves through the drain: the DRBEF2417SEANMC has two 3/4 in NPT condensate connections.

With a central heat pump outside, the cycle reverses in winter and the same coil delivers heat to the air. You keep your furnace, its blower, its filters and your ductwork. This is what we call an "add-on" installation.

Matching it with the outdoor unit

This coil does not pair with just any unit. It is matched with a Durastar outdoor unit of the same capacity and the same refrigerant, so 2 tons on R-454B. A unit of another size or another refrigerant is not an option.

Durastar publishes its efficiency ratings for complete systems, not for the coil alone. Before ordering, we therefore look up the AHRI number that links your coil to the outdoor unit you have chosen. That number also lets you compare two quotes on an honest basis.

Here is what the manufacturer states for its matching outdoor units:

  • DRHP14B and DRHP15B heat pumps from the DRAC series on R-454B, with a two-stage compressor, paired with DRBEF coils and a Durastar furnace;
  • only certain TXV coils are listed on ENERGY STAR, with ratings published for the American market;
  • the other DRHP14B and DRHP15B pairings show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8.

DRBEF2417SEANMC spec sheet

  • manufacturer: Durastar, DRBEF range;
  • type: cased N-shaped evaporator coil;
  • size: 2 tons (24,000 BTU/h), R-454B refrigerant;
  • width: 17-1/2 in (445 × 368 × 508 mm, per the spec sheet);
  • net weight: 43 lb, the lightest in the series;
  • connections: 3/8 in for liquid, 3/4 in for suction;
  • metering device: EEV;
  • drain: two 3/4 in NPT condensate connections;
  • warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);
  • built-in leak detection: A2L sensor and mitigation board in a single housing, factory-installed; the outdoor unit is paused if excess refrigerant is detected; compatible with any 24 V thermostat.

Built-in safety for the new refrigerant

R-454B belongs to the A2L family. For that reason, Durastar mounts a sensor and a mitigation board in a single housing at the factory. If the sensor detects too much refrigerant in the air, the outdoor unit shuts off. There is no separate system to order or connect, and the 24 V thermostat you already have may be suitable.

Which home suits this small size?

Two tons is enough for a townhouse, a small bungalow or the upper floor of a plex with its own furnace. The classic trap is oversizing: a system that is too big shuts off before it has dried the air, and the house stays clammy even though the thermostat shows the right temperature.

So we don't choose the size based on the size of the furnace. We look at the insulation, the south- and west-facing windows, and how you live in the house. If the calculation points to 3 tons, we will tell you and move to another model in the series.

DRBEF2417SEANMC or another model in the series?

Here is how we help our customers decide between neighbouring models.

  • Same 2-ton capacity: the DRBEF2421HEAAMC (A-coil), DRBEF2421HEANMC (N-coil) and DRBEF2421MEANMC (N-coil) offer the same size and the same refrigerant. This model's sheet is the only one that highlights the 17-1/2 in width, a concrete reference point for a small space.
  • More capacity: the DRBEF3621MEAAMC and DRBEF3621MEANMC move up to 3 tons. The DRBEF4821SEAAMC, DRBEF6021SEAAMC, DRBEF6024SEANMC and DRBEF6024STANMC are aimed at large homes.
  • Shape: N-coil like this model, or A-coil if the height above the furnace allows it.
  • Metering device: this coil uses an EEV, like almost the whole series. Only the DRBEF6024STANMC has a TXV.
  • Refrigerant: every model in the series runs on R-454B, so there is no choice to make on that front.

How we install this coil

AirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under our RBQ licence 5645-9605-01. For this model, a typical installation day goes like this:

  1. measuring the furnace and checking the blower and the electrical panel;
  2. setting the cabinet in the plenum, with a sealed and insulated transition if the widths differ;
  3. mounting the outdoor unit on its stand, brazing the piping, pressure-testing with nitrogen and pulling a vacuum;
  4. connecting the condensate drain and the thermostat;
  5. commissioning, adjusting the airflow and explaining the controls.

What to confirm before you buy

  • The 17-1/2 in width is compared with the furnace's width; we take the measurement together.
  • The blower must deliver the airflow the system requires.
  • The coil and the outdoor unit are installed together, with the same refrigerant.
  • The coil has no efficiency rating on its own: the rating belongs to the matched system.

Incentives: we check before we promise

Eligibility for Hydro-Québec programs is not judged on the coil alone, but on the complete system. We consult the official list at the time of the quote, based on the planned installation date, and then tell you what applies to your project.

Get a quote for your furnace

Request your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the work.

01 · What it is for

The heat pump coil for your furnace

The DRBEF2417SEANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF2417SEANMC
TypeCased evaporator coil
LineDRBEF
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceEEV
Liquid connection3/8 in
Suction connection3/4 in
Dimensions W × H × D17-1/2 in
Net weight43 lb
Model numberDRBEF2417SEANMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 17-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.