DURASTAR DRBEF2421HEAAMC Evaporator A-Coil | 2 Tons

In stock

The Durastar DRBEF2421HEAAMC 2-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF2421HEAAMC

2 tons24,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF2421HEAAMC
ManufacturerDurastar
Size2 tons
RefrigerantR-454B
MeteringEEV

DRBEF2421HEAAMC: a 2-ton A-coil to replace an old central air conditioner

Is your central air conditioner wearing out, or have you never had one and your furnace has been running for years? The Durastar DRBEF2421HEAAMC evaporator coil is worth a close look. It is an A-shaped coil that ships with its cabinet, runs on R-454B refrigerant and is sized at 2 tons (24,000 BTU/h). It sits on your existing furnace and receives refrigerant from a matching Durastar outdoor unit. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Five questions homeowners ask us

Can this coil provide heat? Yes, as long as it is paired with a heat pump: it cools in summer and heats in winter. With a simple central air conditioner, it only provides cooling.

Can I keep my current air conditioner? Generally, no. This coil runs on R-454B and must connect to the outdoor unit the manufacturer specifies. We install both parts together.

Is my furnace the right width? We measure it before ordering. If it differs from the cabinet, we prepare an insulated transition on site.

Does the furnace become useless? No. It keeps its blower, and it takes over when the outdoor temperature drops below the threshold we set with you.

What about incentives? They depend on the matched system, and we come back to that below.

Why an A-coil

The A is a coil shape with two sloped faces that meet at the top. Air rises through the centre of the furnace and passes along each side. This geometry is very common above upflow furnaces, and it is the one we install most often when the ceiling height in the basement is not an obstacle.

If height is lacking, the N shape of the DRBEF2421HEANMC or the DRBEF2421MEANMC, with the same capacity, will be a better fit. We check with a tape measure before choosing, not after.

How the cooling cycle works inside it

In the coil's tubes, liquid refrigerant turns to vapour as it absorbs heat from your home's air. Moisture in that air settles on the cold fins and drips into the pan, from which two 3/4 in NPT condensate connections carry it away. The furnace blower then redistributes the cooled air to every room through the existing ducts.

The metering device, an EEV for this model, regulates the flow of refrigerant admitted to the coil. It keeps the coil in its normal operating range, without icing or a shortfall in capacity.

The connections and weight to know about

This model stands apart from its 2-ton cousins with its 7/8 in suction connection (the liquid line stays at 3/8 in) and a net weight of 76 lb. For the installer, these are concrete details: they determine the size of the copper piping to the outdoor unit and how the cabinet is handled on a basement staircase.

The DRBEF2421MEANMC, for example, has a smaller suction connection and a much lighter cabinet. If your job site is tight, this point can tip the balance.

DRBEF2421HEAAMC at a glance

  • brand and range: Durastar, DRBEF;
  • cased A-coil model, 2 tons, R-454B;
  • positions: upflow, downflow, horizontal left or right;
  • connections: 3/8 in liquid, 7/8 in suction;
  • net weight: 76 lb;
  • manufacturer warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);
  • leak detection: A2L sensor and mitigation board factory-installed in a single housing, pausing the outdoor unit if excess refrigerant is detected; compatible with any 24 V thermostat.

Efficiency ratings that belong to the system

Don't look for a SEER2 for the coil alone: it doesn't have one. The published ratings apply to a complete matched system, identified by an AHRI number. According to Durastar, the DRHP14B and DRHP15B heat pumps from the DRAC series on R-454B, with a two-stage compressor, pair with DRBEF coils; most of these combinations show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. We confirm the exact combination before the order.

Choosing between this model and its neighbours in the series

  • A-coil or N-coil: this coil is an A-coil. The DRBEF2421HEANMC, DRBEF2421MEANMC and DRBEF2417SEANMC are N-coils.
  • Capacity: 2 tons here. The DRBEF3621MEAAMC is also an A-coil, but at 3 tons; it suits a larger or more glazed home.
  • Width: this model's sheet does not publish the width; we confirm it on site. The DRBEF2417SEANMC shows 17-1/2 in, which makes it the natural choice for a narrow space.
  • Metering device and refrigerant: EEV and R-454B, like almost every model in the series (only the DRBEF6024STANMC has a TXV).

How Quebec's climate changes the choice

Our summers are short, but humid. One heat-wave week in July is enough to turn a basement or a second floor into a steam room. A properly sized central air conditioner handles the temperature and the humidity at once, whereas a window unit looks after only one room. The 2-ton A-coil is cut out for homes where the load is moderate and a single zone is enough.

If, on the contrary, your upper rooms overheat while the basement stays cool, a single system won't fix everything. We say so during the visit, because it is better to correct the air circulation or the insulation than to buy more tons.

Why we install the outdoor unit and the coil on the same day

A new coil connected to an old outdoor unit is like a chain with a worn link: the capacity, the refrigerant and the piping must agree. Since this model runs on R-454B, the outdoor unit must use the same fluid. Installing both parts together lets us braze new piping, pressure-test with nitrogen and pull the vacuum once, with a single commissioning report to hand you.

How an installation with AirGreen unfolds

A family-owned heating and cooling company based in Montreal for more than fifteen years, AirGreen does its own refrigeration, ventilation and electrical work under RBQ licence 5645-9605-01. For this coil, here are our steps:

  • measuring visit: furnace, blower, electrical panel;
  • setting the cabinet in the plenum and sealing the duct connections;
  • mounting the outdoor unit, brazed piping, nitrogen test, vacuum;
  • connecting the drain and the thermostat;
  • commissioning, airflow adjustment, handing over the operating instructions.

Points to validate before you sign

  • R-454B requires pairing the coil with an outdoor unit using the same refrigerant.
  • The furnace blower must deliver the required airflow.
  • The house's load calculation must confirm that 2 tons is the right choice.

Financial assistance programs

Hydro-Québec incentives are tied to the complete system. We check the official list based on the installation date, then explain what applies before you sign anything.

Taking the next step

Request your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing lets you spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF2421HEAAMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF2421HEAAMC
TypeCased evaporator coil
LineDRBEF
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceEEV
Liquid connection3/8 in
Suction connection7/8 in
Net weight76 lb
Model numberDRBEF2421HEAAMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.