DURASTAR DRBEF2421MEANMC Evaporator N-Coil | 2 Tons

In stock

The Durastar DRBEF2421MEANMC 2-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF2421MEANMC

2 tons24,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF2421MEANMC
ManufacturerDurastar
Size2 tons
RefrigerantR-454B
MeteringEEV

DRBEF2421MEANMC: a 2-ton N-coil, lighter than its 2421 twins

A unit's weight changes nothing about a home's comfort, but it changes a lot for whoever has to carry the cabinet down a narrow staircase. The DRBEF2421MEANMC is a Durastar N-shaped evaporator coil, cased, rated at 2 tons (24,000 BTU/h) and running on R-454B refrigerant. It weighs 51 lb and its suction connection measures 3/4 in. It is installed by AirGreen in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

What sets it apart from the other two DRBEF2421 models

Three models in the series share the same base number, 2421. The HEAAMC (A-coil) and the HEANMC (N-coil) have a 7/8 in suction connection and a noticeably heavier cabinet. This MEANMC drops to 51 lb with a 3/4 in connection. The liquid connection stays at 3/8 in for all three.

On the job site, that means a cabinet that is easier to carry and slightly smaller copper piping on the suction side. For the homeowner, the difference shows mostly on installation day.

The N, for compact spaces

Its tubing forms three zigzag faces, in a cabinet shorter than an A-coil. Under a beam or in a narrow mechanical room, this size makes it possible to fit a coil where others wouldn't pass. The cabinet is insulated and ready to set on the furnace, which speeds up installation and improves air tightness.

The model is multi-position: upflow, downflow, horizontal left or right.

What a coil's day looks like

As soon as the thermostat calls for cooling, the outdoor unit sends refrigerant to the coil. The coil absorbs heat from the air passing through it, and condensation water runs to the pan, then to the two 3/4 in NPT condensate connections. An EEV-type metering device doses the refrigerant as needed. The cooled air goes back out through the ducts.

In winter, with a heat pump, the direction of the cycle is reversed. This coil then becomes the starting point of the heat distributed through the house.

Quick spec sheet

  • model: DRBEF2421MEANMC;
  • brand: Durastar, DRBEF range;
  • shape: N, cased;
  • size: 2 tons (24,000 BTU/h), R-454B refrigerant;
  • metering: EEV;
  • connections: liquid 3/8 in, suction 3/4 in;
  • net weight: 51 lb;
  • manufacturer warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);
  • leak detection: a factory-mounted A2L sensor and mitigation board, which suspend the outdoor unit when there is excess refrigerant; standard 24 V thermostat accepted.

What does a certified match mean?

A coil alone has no efficiency rating. SEER2, EER2 and HSPF2 values belong to a specific combination of coil and outdoor unit, identified by an AHRI number. For the DRBEF series, Durastar mentions its DRHP14B and DRHP15B heat pumps (DRAC series, R-454B, two-stage), most of whose pairings show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. We confirm the combination in the AHRI directory before the order.

Do you really need 2 tons?

A townhouse, a small bungalow or a plex unit with its own furnace suits this size well. Conversely, a system bigger than necessary shuts off too early, leaves humidity in the air and ends up giving a clammy, cold feeling. We calculate the needs before proposing a size, and we prefer to steer you toward 3 tons if that is what the house calls for.

MEANMC, HEAAMC, HEANMC: how to decide

  • The lightest to handle among the three 2421 models: the MEANMC, at 51 lb.
  • If you have height: the DRBEF2421HEAAMC, an A-coil, becomes a candidate.
  • If space is tight and the existing piping is larger: the HEANMC keeps the N shape with a 7/8 in connection.
  • If width is decisive: the DRBEF2417SEANMC publishes 17-1/2 in.
  • If the house is larger: the DRBEF3621MEAAMC and DRBEF3621MEANMC offer 3 tons.

A small system, but a real calculation process

Just because the size is modest doesn't mean we can improvise. We start with the walls and windows, then look at the orientation of the house, the ceiling height and the number of people living in it. A well-insulated bungalow in Laval doesn't have the same needs as a cottage with west-facing windows on the South Shore.

The result fits on one page: the estimated load, the recommended size and the reason for that choice. If 2 tons is right, this coil is a strong candidate. If not, we steer you to a larger model without pushing.

Winter heating with a heat pump

With a heat pump outside, this coil takes on a second role. In winter, it gives the home's air the heat captured outdoors. The furnace only starts below the threshold we program, which avoids heating with electricity on days when the heat pump is enough. You keep the existing ducts and a single thermostat for both seasons.

How AirGreen installs this coil

Our family-owned heating and cooling company has been based in Montreal for more than fifteen years. We hold RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.

  • Step one: measuring the furnace, checking the blower and the panel.
  • Step two: setting the cabinet in the plenum, with a transition built on site if the width doesn't match.
  • Step three: outdoor unit on its base, brazed copper, nitrogen, vacuum.
  • Step four: condensate drain and thermostat.
  • Step five: commissioning, airflow and an explanation of how it works.

What to check before buying

  • The outdoor unit must use the same refrigerant, R-454B.
  • The furnace width is not published for this model: we take it on site.
  • The announced ratings apply to the certified match.

The leak sensor, a reassuring detail

R-454B is a refrigerant in the A2L family, and Durastar built a response into the unit itself: a sensor and a mitigation board, grouped in a single housing installed at the factory. If the sensor measures excess refrigerant, the outdoor unit is paused. You have nothing to add, and the usual 24 V thermostat can be used. We test this device at commissioning, then explain what it does.

Incentives

The coil does not qualify on its own: it is the complete system that is assessed. We consult the official Hydro-Québec list based on the installation date, then tell you exactly what is possible.

Estimate and financing

Request your free estimate: we come to your home, measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF2421MEANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF2421MEANMC
TypeCased evaporator coil
LineDRBEF
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceEEV
Liquid connection3/8 in
Suction connection3/4 in
Net weight51 lb
Model numberDRBEF2421MEANMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.