DURASTAR DRBEF2421HEANMC Evaporator N-Coil | 2 Tons

In stock

The Durastar DRBEF2421HEANMC 2-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF2421HEANMC

2 tons24,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF2421HEANMC
ManufacturerDurastar
Size2 tons
RefrigerantR-454B
MeteringEEV

Low basement, low ceiling: the DRBEF2421HEANMC, a 2-ton N-coil

In many Greater Montreal homes, the furnace sits in a basement corner where a beam, a duct or a dropped ceiling limits the height. That is exactly the setting for which you choose an N-shaped coil. The DRBEF2421HEANMC is a 2-ton (24,000 BTU/h) Durastar evaporator coil, cased, running on R-454B refrigerant. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.

A common scenario

A family in Longueuil owns a bungalow from past decades with an electric furnace. They want to cool in summer and cut the winter bill. In the mechanical room, there is little clearance left between the top of the furnace and the ceiling. An A-coil wouldn't fit without moving everything; an N-coil slips into the same space.

This kind of constraint is settled with a tape measure, not a catalogue. During our visit, we measure the available height before we even talk about brands.

The N shape, concretely

The coil's tubing is folded into three zigzag faces. The whole is shorter than the A version for the same capacity, which gives a cabinet better suited to tight spaces. The DRBEF2421HEANMC ships in an insulated cabinet, ready to set on the furnace, which cuts installation time and limits air leaks around the coil.

It mounts in upflow, downflow or horizontal position, left or right.

What it brings to an add-on system

Your furnace keeps its role as the air mover: its blower, filters and ducts stay in place. The coil is inserted in the path of the air. In summer, it removes heat and humidity; in winter, when paired with a heat pump, it returns heat. The furnace only steps in if the outdoor temperature drops below the threshold programmed with you, for example during a January cold snap.

No rating on its own, but a certified system

A coil carries no SEER2 or HSPF2 rating of its own. Those figures belong to the coil and outdoor unit together, linked by an AHRI number. Durastar publishes combinations with its DRHP14B and DRHP15B heat pumps (DRAC series, R-454B, two-stage compressor): those not certified for cold climates show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. We verify the exact combination before buying, so that the ratings promised are the ones you get.

Technical data for the model

  • model: DRBEF2421HEANMC, Durastar DRBEF range;
  • type: cased N-coil;
  • size: 2 tons, 24,000 BTU/h;
  • refrigerant: R-454B, EEV metering;
  • connections: 3/8 in (liquid) and 7/8 in (suction);
  • condensate drain: two 3/4 in NPT connections;
  • net weight: 71 lb;
  • warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);
  • safety: factory A2L sensor and mitigation board, which pause the outdoor unit if excess refrigerant is detected; works with any 24 V thermostat.

The DRBEF2421HEANMC compared with its neighbours

When the choice comes down to several similar-looking model numbers, here are the differences we keep in mind for you.

  • Versus the DRBEF2421HEAAMC: same capacity, same connections, but an A-coil. If your ceiling is low, the N shape of this model is the one to pick; if you have height, the A remains possible. The N cabinet is also a little lighter than the A.
  • Versus the DRBEF2421MEANMC: same shape, same capacity, but the latter has a smaller suction connection and weighs noticeably less.
  • Versus the DRBEF2417SEANMC: same capacity and same shape, with a cabinet whose published width is 17-1/2 in.
  • Versus the DRBEF3621MEANMC: same shape, but 3 tons, for a larger home.

The winter bill, explained simply

An electric furnace turns every kilowatt-hour into an equal amount of heat. A heat pump instead moves heat from outside to inside: in mild weather, it delivers two to three times more heat than the electricity it consumes. That efficiency drops with the cold, which is why the furnace stays as backup. The N-coil in this model is the link that brings that heat into your existing ducts.

We set with you the temperature threshold at which the furnace takes over. For a family in Laval or on the North Shore, that means a heat pump that works most of the season and a furnace that holds itself in reserve for cold peaks.

What we check before installing

The plenum must be able to receive the cabinet without crushing the filter or blocking access to components. We also look at the alignment of the drain, because condensation water must flow to a low point with no slope running the wrong way. Finally, we check that the electrical circuit for the outdoor unit is ready to take the heat pump's load. These three points avoid most surprises on installation day.

Our installation method

AirGreen is a family-owned heating and cooling company in Montreal, active for more than fifteen years, holding RBQ licence 5645-9605-01 for its refrigeration, ventilation and electrical work.

  1. We take the measurements: available height, furnace width, condition of the electrical panel.
  2. We set the cabinet in the plenum, and we seal the connections with the ducts.
  3. We install the outdoor unit, braze the piping, pressure-test with nitrogen, then pull the vacuum.
  4. We connect the drain and the thermostat.
  5. We start up the system, adjust the airflow and show you the settings.

Before you decide

  • The coil and the outdoor unit are chosen at the same time, with the same refrigerant.
  • The furnace width, unknown on the spec sheet, is checked on site.
  • The blower must deliver the system's airflow.

Maintenance: what you can do yourself

A clean coil works better. The simplest step is to change the furnace filter at the rate the manufacturer recommends, since dust that gets past the filter ends up on the fins. Also keep an eye on the drain: if you see water around the cabinet in the middle of a heat wave, call us before the floor suffers. An annual check before summer lets us clean the pan and confirm that the leak sensor and the thermostat are communicating properly.

We don't promise a specific lifespan for any unit, because it depends on the quality of the installation, the maintenance and the use. What we do guarantee is an installation done to the standards of the trade.

Government assistance

Eligibility for incentives depends on the matched system and not on the coil alone. We consult the official Hydro-Québec list based on the installation date and tell you what applies.

Your estimate, on site

Book your free estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF2421HEANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF2421HEANMC
TypeCased evaporator coil
LineDRBEF
Nominal size2 tons (24,000 BTU/h)
RefrigerantR-454B
Metering deviceEEV
Liquid connection3/8 in
Suction connection7/8 in
Net weight71 lb
Model numberDRBEF2421HEANMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 2-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.