DURASTAR DRBEF3621MEAAMC Evaporator A-Coil | 3 Tons
The Durastar DRBEF3621MEAAMC 3-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF3621MEAAMC
514 316-2973 · sales@airgreen.ca
Quick facts
Three tons, A-coil shape: the DRBEF3621MEAAMC for the mid-sized home
Between the small bungalow and the large multi-storey property, there is a wide range of mid-sized homes: suburban cottages, split-levels, semi-detached houses with a finished basement. For them, the 3-ton size (36,000 BTU/h) is often the starting point of the discussion. The DRBEF3621MEAAMC is a Durastar evaporator coil of that capacity, A-shaped, cased, running on R-454B refrigerant. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Three common mistakes this size helps you avoid
First mistake: choosing by floor area alone. Two homes with the same floor area can call for different capacities depending on insulation, windows and orientation. We do a load calculation, not a rule of thumb.
Second mistake: neglecting the blower. At 3 tons, the airflow the coil requires is greater than with a small model. If the furnace blower can't deliver it, the coil may ice up or the house will lack comfort. We check before ordering.
Third mistake: buying a coil without thinking about the outdoor unit. The two parts are a couple. The outdoor unit must have the same capacity and run on R-454B.
The A shape, its logic and its footprint
The A-coil rests on two sloped faces that join at the top. Air rises along the furnace axis and passes through each face. It is a classic geometry for upflow furnaces, and it suits mechanical rooms that offer a bit of height above the unit.
If clearance is limited, the N version of the same capacity, the DRBEF3621MEANMC, offers a shorter cabinet. We help you decide by measuring the real space.
A coil for air conditioning and heating at once
On its own, a coil produces nothing: the outdoor unit supplies the refrigerant, and the coil exchanges heat with your home's air. With a central air conditioner, it cools in summer. With a heat pump, it also heats in winter, using the same ducts. The furnace keeps its blower and serves as backup during the deep cold.
The condensation water that forms on the coil runs into the pan and leaves through the two 3/4 in NPT condensate connections. The metering device is an EEV.
DRBEF3621MEAAMC data
- manufacturer and range: Durastar, DRBEF;
- type: cased A-coil;
- size: 3 tons, 36,000 BTU/h;
- refrigerant: R-454B;
- connections: 3/8 in for liquid, 7/8 in for suction;
- positions: upflow, downflow, horizontal left or right;
- net weight: 76 lb;
- warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);
- leak detection: factory-installed A2L sensor and mitigation board, pausing the outdoor unit if excess refrigerant is detected, compatible with any 24 V thermostat.
Efficiency: reading the ratings correctly
The coil has no rating on its own. SEER2, EER2 and HSPF2 values describe a system, that is, a specific outdoor unit linked to a specific coil, with an AHRI number. Durastar states that its DRHP14B and DRHP15B heat pumps, from the DRAC series on R-454B and with a two-stage compressor, pair with DRBEF coils; the standard pairings show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. Only certain TXV coils are listed on ENERGY STAR, with ratings for the American market.
This detail matters when you compare two quotes: always ask for the AHRI number.
How this model compares with the series
- To the DRBEF3621MEANMC: same capacity and same connections; the latter is an N-coil, so shorter.
- To the 2-ton models (DRBEF2421HEAAMC, DRBEF2421HEANMC, DRBEF2421MEANMC, DRBEF2417SEANMC): lower capacity, for small homes or a plex unit.
- To the DRBEF4821SEAAMC: same A shape, but 4 tons, for a larger home or higher airflow.
- To the 5-ton models (DRBEF6021SEAAMC, DRBEF6024SEANMC and DRBEF6024STANMC): for the largest properties.
- Metering device: this model has an EEV, like most of its neighbours; only the DRBEF6024STANMC has a TXV.
Humidity, noise, comfort: what we really look at
Many homeowners judge an air conditioning system on a single criterion: the thermostat temperature. Yet the feeling of comfort also comes from the humidity of the air. A properly sized coil runs long enough to dry the air, whereas an oversized coil short-cycles and leaves an unpleasant clamminess. That is one of the reasons we don't sell one size up "just in case."
Air noise in the ducts is another clue. If the vents whistle, it is often because the ducts or filters are limiting the flow. We take that into account, because a 3-ton system only delivers its full effect if the air circulates freely.
What remains of your current installation
In most cases, the furnace, filters and ducts stay. What changes: the coil in the plenum, the outdoor unit, the refrigerant piping, the drain and the thermostat. It is a relatively limited renovation that requires no demolition and no new ducts in the walls. It still comes with a check of the electrical panel, because the heat pump or the outdoor air conditioner needs its own circuit.
An installation carried out by a single team
AirGreen has been a family-owned heating and cooling company in Montreal for more than fifteen years, and we work under RBQ licence 5645-9605-01. The same people handle the refrigeration, ventilation and electrical side of your project.
- Measuring the furnace, checking the blower and the electrical panel.
- Setting the coil in the plenum, sealing the duct connections, insulated transition if the width differs.
- Placing the outdoor unit on its base, brazed piping, nitrogen pressure test, vacuum.
- Connecting the drain and the thermostat.
- Commissioning, airflow adjustment, demonstration of the controls.
Questions to ask before ordering
- Is the furnace width compatible with the cabinet? We measure it at your home.
- Does the blower reach the airflow a 3-ton system calls for?
- Does the load calculation confirm this size?
- Does the outdoor unit use R-454B?
A word about the warranty
Durastar offers a conditional 10-year parts warranty, with registration (sheet CDS-228). The word "conditional" matters: the unit must be registered, and the installation must be done to the rules. We handle this step with you at commissioning, so the registration deadline isn't missed.
Hydro-Québec incentives
The programs apply to the complete system, not the coil alone. We consult the official list at the time of the quote, taking the installation date into account, then tell you what applies to your file.
Next step: a visit
Request your free on-site estimate. We measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The DRBEF3621MEAAMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Durastar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
