DURASTAR DRBEF6024SEANMC Evaporator N-Coil | 5 Tons
The Durastar DRBEF6024SEANMC 5-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF6024SEANMC
514 316-2973 · sales@airgreen.ca
Quick facts
DRBEF6024SEANMC: a 24-1/2 in N-coil cabinet for 5-ton systems under low ceilings
Large capacities are often associated with big, bulky cabinets. The DRBEF6024SEANMC takes the opposite approach: it is a 5-ton (60,000 BTU/h) Durastar evaporator coil, N-shaped and therefore shorter than an A, with a cabinet 24-1/2 in wide and an EEV metering device. It runs on R-454B refrigerant. AirGreen installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.
Reading the spec sheet: three key facts
What characterizes this model fits in three lines: N shape, 24-1/2 in width, EEV metering. Each has a consequence on the job site.
- The N shape limits the height of the cabinet, useful under a beam or in a low mechanical room.
- The 24-1/2 in width must be compared with the furnace's. When they don't match, we build an insulated transition.
- The EEV regulates the flow of refrigerant in the coil, as opposed to the TXV of its twin, the DRBEF6024STANMC.
A large capacity doesn't rule out a compact space
A North Shore family in a large split-level home, where the furnace sits under a low ceiling: that is the kind of case where this model makes full sense. The A-coil of the same capacity, the DRBEF6021SEAAMC, would have required height that the basement doesn't offer. Here, the N lets the 5 tons fit in a restricted space, without breaking through a ceiling.
The cabinet is insulated and delivered ready to set on the furnace. It mounts in upflow, downflow or horizontal position, left or right.
What the EEV does for you
An electronic expansion valve, or EEV, adjusts the passage of refrigerant in the coil by means of an electrical control, rather than relying only on a mechanical part. For a homeowner, this boils down to precise control of the coil, which works in its normal operating range. We have no figure to offer on energy gain: efficiency depends on the certified system, not on the coil alone.
The piping and connections
The liquid line arrives at 3/8 in and the suction line leaves at 7/8 in. The condensate drain has two 3/4 in NPT connections. At 5 tons, a pan that drains well is crucial in midsummer: we test the flow at commissioning. The net weight of the unit is 100 lb, which takes two people to handle the cabinet and lift it onto the furnace.
DRBEF6024SEANMC model spec sheet
- manufacturer: Durastar, DRBEF range;
- type: cased N-coil;
- size: 5 tons (60,000 BTU/h);
- refrigerant: R-454B;
- width: 24-1/2 in;
- metering device: EEV;
- connections: liquid 3/8 in, suction 7/8 in;
- net weight: 100 lb;
- warranty: conditional 10-year parts warranty, with registration (sheet CDS-228);
- safety: factory A2L sensor and mitigation board; the outdoor unit pauses if excess refrigerant is detected; standard 24 V thermostat accepted.
Choosing between the DRBEF6024SEANMC and the DRBEF6024STANMC
These two coils look very much alike: same N shape, same 24-1/2 in width, same 5-ton capacity, same connections, same net weight of 100 lb. The difference lies in the metering device and the published pairing.
- DRBEF6024SEANMC (this one): EEV. The pairing is confirmed case by case in the AHRI directory.
- DRBEF6024STANMC: TXV, with published pairings for the DRHP15B60AJ2AN outdoor unit, so simpler to document for an incentive application.
If the incentive file weighs heavily in your decision, this is a factor to know about. If the available height is generous, you can also consider the DRBEF6021SEAAMC, an A-coil.
Where it sits in the series
- 4 tons: DRBEF4821SEAAMC, A-coil.
- 3 tons: DRBEF3621MEAAMC (A) and DRBEF3621MEANMC (N).
- 2 tons: DRBEF2421HEAAMC, DRBEF2421HEANMC, DRBEF2421MEANMC and DRBEF2417SEANMC.
Winter heating with a heat pump
With a heat pump outside, this coil gives the home's air the heat harvested outdoors. Because the heat pump moves heat instead of making it, in mild weather it delivers two to three times more heat than the electricity it consumes; this efficiency declines with the cold, and the furnace takes over below the threshold we program with you. For a large home, that is often where the difference on the winter bill is made.
What we do with the existing furnace
We keep the furnace, its blower and its filters. We check that the blower can deliver the system's airflow, because a 5-ton coil needs a lot. If it can't, we say so clearly and propose the options, rather than letting a new system run at half strength.
Why Durastar
Durastar is the heating and air conditioning brand of Ferguson, distributed in Canada by Wolseley. Its DRBEF coils, on R-454B, are installed with Durastar heat pumps and central air conditioners on a furnace.
The installation work
We are a family-owned heating and cooling company, based in Montreal for more than fifteen years. RBQ licence 5645-9605-01 covers refrigeration, ventilation and electrical work.
- Visit: available height, furnace width, electrical panel.
- Cabinet on the plenum, insulated transition if needed, sealed connections.
- Outdoor unit on a base, brazed copper, nitrogen, vacuum.
- Drain and thermostat.
- Commissioning, airflow, demonstration.
To check before ordering
- The electrical service must accommodate the circuit of an outdoor unit this size.
- The 24-1/2 in width is compared with the furnace's.
- The blower must deliver the system's airflow.
- R-454B requires pairing the coil with an outdoor unit using the same refrigerant.
The built-in leak sensor
R-454B belongs to the A2L category. Durastar therefore mounts a sensor and a mitigation board, grouped in one housing, on this coil at the factory. If the sensor detects excess refrigerant, the outdoor unit shuts off. There is no module to add, and a standard 24 V thermostat may be suitable. We verify the device's operation at commissioning, then explain what it does.
The drain, water and summer
At 5 tons, the volume of condensation water can be considerable in humid weather. The two 3/4 in NPT condensate connections must lead to a well-sloped drain, and we test the flow with water before leaving. A dry mechanical room is also proof that the installation was done properly.
Incentives
Eligibility depends on the matched system, not on the coil alone. We consult the official Hydro-Québec list with the installation date and tell you what applies.
Estimate
Request your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.
The heat pump coil for your furnace
The DRBEF6024SEANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Durastar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- The coil is 24-1/2 in wide; we check the furnace before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 5-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.