DURASTAR DRBEF4221HTAAMC Evaporator A-Coil | 3.5 Tons
The Durastar DRBEF4221HTAAMC 3.5-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF4221HTAAMC
514 316-2973 · sales@airgreen.ca
Quick facts
Durastar DRBEF4221HTAAMC coil: 3.5-ton A-coil, the in-between size for homes between 3 and 4 tons
There is a category of homes that capacity charts handle poorly: those that are a little too big for three tons but do not need four. The DRBEF4221HTAAMC exists for them. It is an A-shaped, cased evaporator coil with a nominal size of 3.5 tons (42,000 BTU/h) and R-454B refrigerant, made by Durastar in the DRBEF series. This page answers, one question at a time, the questions homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore ask us before choosing.
What is an evaporator coil for?
It is the heat exchanger located in the plenum, in the path of your furnace's air. In summer, the liquid refrigerant turns into gas there by absorbing heat from the air; the moisture that condenses on it is carried off by the drain. With a heat pump, the cycle reverses in winter and the same coil releases heat into your ducts. Without it, the furnace blows air, and nothing more.
Why 3.5 tons rather than 3 or 4?
Because the size of a system follows the house, not the other way around. The 3.5-ton size sits between the two: it offers a more generous heat-exchange surface than the 3-ton model, without requiring the blower of a 4-ton model. It suits a two-storey home, a large single-storey house or a house with an addition whose ducts serve quite a few rooms.
Our method: we look at the floor area, the windows, the insulation and the orientation, then the blower. If the blower cannot push the airflow this size needs, it is better to know before the order than to guess in July.
Why the A shape?
The A-coil has two sloped faces that meet at the top. Air from the furnace rises toward the centre and passes through both planes. It is the most common configuration on upflow furnaces, which makes replacing an old model much easier. The price to pay is height: you need space above the furnace. If the ceiling is low, look instead at the N-coils in the same series.
How is it installed?
The cabinet is insulated and delivered ready to install, which means a faster installation and better-sealed joints. The manufacturer states that the coil is multi-position: upflow, downflow, horizontal left or right. It uses a TXV metering device and has two 3/4 in NPT condensate connections. The refrigerant connections are 3/8 in for the liquid line and 7/8 in for the suction line. The net weight is 76 lb.
Do you also need to replace the outdoor unit?
Almost always. The coil runs on R-454B and must be matched with a Durastar outdoor unit of the same capacity and the same refrigerant. Keeping the old condenser is not a good idea: the fluids are not the same. So we install the complete system, and we confirm the match in the AHRI directory before placing the order.
How efficient is it?
The coil has no rating of its own. The SEER2, EER2 and HSPF2 ratings describe a certified system, meaning a coil, an outdoor unit and an AHRI number that links them. Durastar's DRHP14B and DRHP15B heat pumps, R-454B models with a two-stage compressor, are matched with DRBEF coils and a Durastar furnace. Outside the certified cold-climate matches, these systems show a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8.
HTAA or STAA: what is the difference between the two 3.5-ton models?
The catalogue contains two 3.5-ton part numbers: this DRBEF4221HTAAMC and the DRBEF4221STAAMC. Both are A-coils, with R-454B and a TXV. Their published specifications are identical, including the 76 lb weight. A useful note: among the standard-efficiency coils that Durastar lists as ENERGY STAR, there is no 3.5-ton in the list. So do not choose one or the other based on that logo. Tell us instead which outdoor unit you have in mind, and we will validate the match.
Comparing it with the rest of the series
- DRBEF3624MTANMC, 3 tons, N-coil, 24-1/2 in wide: for a smaller furnace or a low ceiling.
- DRBEF4821HTAAMC and DRBEF4821STAAMC, 4 tons, A-coil: same profile as this model, but one step up in capacity.
- DRBEF4821STANMC, DRBEF4824MTANMC and DRBEF4824STANMC, 4 tons, N-coil.
- DRBEF6021STAAMC (A) and DRBEF6024HTANMC (N), 5 tons.
If you are on the borderline between two sizes, bring us your heating and cooling bills for the last two years, or simply your observations: the room that never reaches temperature, the bedroom under the roof. That weighs as much as floor area.
What sizing mistakes should you avoid?
The first is choosing the size based on the old unit. If the old air conditioner was undersized, the house lacked cooling for years; if it was oversized, it shut off too quickly and left the air humid. In both cases, the old label does not tell you what you need today. The second mistake is to look only at capacity and forget the air distribution system: ducts that are too narrow choke any coil. The third is to neglect the furnace itself, because it is the furnace that blows air through the exchanger.
With the DRBEF4221HTAAMC, the risk of error is low if you follow the order: measure the plenum, check the blower, then match it with the outdoor unit.
How do you maintain it?
A properly installed coil needs little, but that little matters. Change the filter on the schedule recommended for your furnace, so that dust does not clog the fins. Check from time to time that water flows through the condensate drain; a blocked pipe eventually overflows the pan. And ask for an annual check before the warm season: it is the time to spot a leak or an airflow that has changed. We offer these visits to customers in Montreal, Laval, Longueuil and both shores.
What is leak detection?
R-454B requires monitoring. A factory-installed box combines a sensor and a board that shut off the outdoor unit if an excessive amount of refrigerant is detected. It works with any 24 V thermostat (see the CDS-228 sheet for details). The manufacturer also provides a conditional 10-year parts warranty, with registration.
What does our installation include?
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work are carried out under RBQ licence 5645-9605-01. Our work includes:
- an examination of the furnace, the blower and the electrical panel;
- installing the coil in the plenum and sealing the air connections, with a transition if needed;
- installing the outdoor unit, brazed piping, a nitrogen test and a vacuum;
- the condensate drain and the thermostat;
- start-up, airflow adjustment and a demonstration.
Is there financial assistance?
It depends on the matched system and the installation date, not on the coil alone. We consult Hydro-Québec's official list when we prepare the quote and tell you what applies.
What comes next?
Book a free estimate at your home. We take the furnace measurements, validate the electrical supply and give you a written price for the complete Durastar system. Financing lets you spread the cost.
The heat pump coil for your furnace
The DRBEF4221HTAAMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Durastar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 3.5-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.
