DURASTAR DRBEF4821STAAMC Evaporator A-Coil | 4 Tons
The Durastar DRBEF4821STAAMC 4-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF4821STAAMC
514 316-2973 · sales@airgreen.ca
Quick facts
DRBEF4821STAAMC: the 4-ton A-coil that Durastar lists among its standard-efficiency ENERGY STAR models
Among this model's nine siblings, a few have a trait the others do not: the ENERGY STAR mention in the manufacturer's documentation. The DRBEF4821STAAMC is one of them. An A-shaped, cased evaporator coil of 4 tons (48,000 BTU/h), using R-454B, it installs on a furnace or a blower cabinet and pairs with a Durastar outdoor unit. Here is what that means, and what it does not mean, for a homeowner in Montreal, Longueuil, Laval, the South Shore or the North Shore.
The ENERGY STAR mention, spelled out
Durastar specifies that only the standard-efficiency TXV coils 3617S, 3621S, 4821S, 4824S, 6021S (A) and 6024S appear on ENERGY STAR, with ratings published for the US market. The "4821S" in that list matches the code of this model. That said, this coil has no efficiency rating of its own: the listing applies to the whole system. So keep two things in mind. First, it is one more point in its favour when you compare part numbers. Second, the figures that matter for your bill are those of the matched system, with its AHRI number.
Decoding the part number
A code like DRBEF4821STAAMC looks like a licence plate. Here is what can be taken from it with confidence:
- DRBEF is Durastar's series of cased coils;
- the number that follows corresponds to the 48,000 BTU/h size, which is 4 tons;
- the "S" is the letter found in the ENERGY STAR list above;
- the "A" that follows designates the A shape.
For the rest, we do not give you an interpretation that the manufacturer has not published.
The A shape and what it requires
Two sloped surfaces that meet at the top, with air passing through the centre: the profile is familiar to any installer. It suits upflow furnaces and requires available height. The net weight is 76 lb. The manufacturer states that it is multi-position: upflow, downflow, horizontal left or right.
The connections: 3/8 in on the liquid side, 7/8 in on the suction side. Two 3/4 in NPT condensate connections serve the drain. The metering device is a TXV, which modulates the refrigerant flow.
The coil through the year
In summer, the tubes are cold and capture heat as well as moisture from the air of the house. In winter, with a heat pump, the direction reverses and the heat brought in from outdoors passes into the duct air. The furnace stays in place and kicks in as backup below a threshold set with you.
Matching: yours to verify
The coil and the outdoor unit are installed together, with the same refrigerant and the same capacity. Durastar pairs its DRBEF coils with the DRHP14B and DRHP15B heat pumps, with a two-stage compressor. Outside the two certified cold-climate matches (see the DRBEF4821STANMC and the DRBEF4824STANMC), the published ratings are a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8. For this A-coil, we confirm the AHRI number in the directory before ordering.
Four tons in an A-coil: who is it for?
For homes whose blower can sustain the airflow of a four-ton system: a large two-storey home, a multi-storey house with generous ducts, a sprawling single-storey home. This is not a promise about floor area: we check the blower, the air returns and the plenum, then we confirm the size or propose another.
Choosing among the models in the series
- DRBEF4821HTAAMC: same capacity, same shape, same published specifications; the ENERGY STAR mention in the list above does not attach to it, because the list cites the 4821S.
- DRBEF4821STANMC: 4-ton N-coil, tied to the DRHP15B42AJ2AN outdoor unit; choose it if height is lacking.
- DRBEF4824STANMC: 4-ton N-coil, 24-1/2 in wide, also in the ENERGY STAR list (4824S).
- DRBEF4824MTANMC: 4-ton N-coil, 24-1/2 in wide.
- Other sizes: 3 tons (DRBEF3624MTANMC), 3.5 tons (DRBEF4221HTAAMC, DRBEF4221STAAMC), 5 tons (DRBEF6021STAAMC, DRBEF6024HTANMC).
What does "standard efficiency" mean?
The phrase is the one Durastar uses to designate these TXV coils in its ENERGY STAR list; it is not a judgment on quality. It says nothing about build quality and does not mean the system will be mediocre. A well-sized, well-installed and well-adjusted system produces steady results, whether or not the part number is standard. Conversely, a quality system that is poorly installed costs dearly in discomfort. Our job is to make the gap between the spec sheet and the house as thin as possible.
And in everyday life?
You set the thermostat, the house cools down in July, and the furnace takes over again when the cold gets serious. The filter needs to be changed from time to time, the drain stays clear and the outdoor unit free of snow. If a detail worries you, an annual check puts things back in order before the season begins.
Built-in leak detection
The A2L sensor and its mitigation board are combined in a single box installed at the factory on models without the L suffix. If an excessive amount of refrigerant is detected, the outdoor unit is paused. Any 24 V thermostat will do (CDS-228 sheet). The manufacturer offers a conditional 10-year parts warranty, with registration.
An example home for this coil
A two-storey home in Laval with an upflow furnace in a spacious utility room, large open spaces on the main floor and bedrooms upstairs. Height is no concern, the blower has been checked, and the owner wants a part number that appears in the manufacturer's list. The DRBEF4821STAAMC ticks those boxes, provided that the match and the AHRI number are confirmed before the order.
What we do, from A to Z
AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01.
- measuring the furnace, the blower and the electrical panel;
- installing the coil in the plenum, insulated transition if needed, sealed joints;
- outdoor unit on a base, brazing, nitrogen test, vacuum;
- condensate drain and thermostat;
- commissioning, airflow adjustment and an explanation of how it works.
Rebates and the LogisVert program
Eligibility depends on the matched system and the installation date, not on the coil alone. At the time of the quote, we verify the match on Hydro-Québec's official list and tell you what applies to your project, including for the LogisVert rebate.
Move on to the estimate
Come to us, or rather let us come to you: a free on-site estimate, furnace measurements, a check of the electrical service and a written quote for the complete Durastar system. Financing is available to spread the cost.
The heat pump coil for your furnace
The DRBEF4821STAAMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with a matching Durastar outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.