DURASTAR DRBEF6024HTANMC Evaporator N-Coil | 5 Tons

In stock

The Durastar DRBEF6024HTANMC 5-ton R-454B cased coil sits on your furnace and, matched with a matching Durastar outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF6024HTANMC

5 tons60,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedR-454B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF6024HTANMC
ManufacturerDurastar
Size5 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV

DRBEF6024HTANMC: 5 tons in a 24-1/2 in N-coil cabinet, the solution when the basement ceiling is low

Some homes need a big system and have little space. Think of a two-storey home on the South Shore whose basement was finished with a dropped ceiling, or a Montreal house whose furnace is squeezed under pipes. The Durastar DRBEF6024HTANMC evaporator coil answers that constraint: an N-shaped coil in its cabinet, of 5 tons (60,000 BTU/h), using R-454B refrigerant, with a width of 24-1/2 in. We also install it in Laval, in Longueuil and on the North Shore.

The dilemma of a large size under a low ceiling

A 5-ton capacity demands a large heat-exchange surface. An A-coil provides it by gaining height. The N-coil spreads it over three faces in a zigzag and occupies a cabinet that is less tall. That is the compromise this model offers. If you have height to spare, its A-coil cousin, the DRBEF6021STAAMC, is a lighter option; if height is tight, this is the model to choose.

What exactly you are buying

  • An evaporator coil with an insulated cabinet, ready to install.
  • A nominal size of 5 tons, which is 60,000 BTU/h.
  • R-454B refrigerant.
  • A TXV metering device.
  • A width of 24-1/2 in and a net weight of 100 lb.
  • 3/8 in (liquid) and 7/8 in (suction) connections, with two 3/4 in NPT condensate connections.
  • A multi-position installation: upflow, downflow, horizontal left or right.

One hundred pounds: what it implies

Together with the DRBEF4824MTANMC, it is the heaviest in the series. The A-coil DRBEF6021STAAMC is lighter. For you, it is not a concern: we come as two, we prepare the route down the stairs and we support the cabinet properly, especially in a horizontal installation. But it is one more reason to do the measuring visit before ordering.

A width to compare with your plenum

The 24-1/2 in of this model must agree with the width of the furnace. When it is not exactly the case, an insulated transition is built on site. We measure, we confirm, then we order. Nothing is left to approximation.

The match is still to be chosen with you

This coil's sheet does not designate a single outdoor unit. So together we choose a Durastar unit of the same capacity and the same refrigerant, then we verify the system's AHRI number in the directory before placing the order. The coil has no rating of its own: SEER2, EER2 and HSPF2 describe a certified system. Durastar pairs its DRBEF coils with the DRHP14B and DRHP15B heat pumps, with a two-stage compressor, and a Durastar furnace. Outside the two cold-climate certified matches, the published ratings are a SEER2 of 15.2, an EER2 of 11.7 and an HSPF2 of 7.8.

A useful clarification: among the standard-efficiency TXV coils listed on ENERGY STAR according to Durastar is code 6024S; this model carries the letters HT and not ST, so we do not attach it to that list.

A system that heats, a furnace that assists

In summer, the coil cools and dries the air in the ducts. In winter, with a heat pump, it gives back the heat captured outdoors. The furnace keeps its blower, its filters and its ducts, and takes over below a threshold that we program with you. For a large home, that is a reassuring safety net for the coldest days.

Choose it or choose another?

  • DRBEF6021STAAMC: 5-ton A-coil, DRHP14B60AJ2AN outdoor unit; lighter and tied to an AHRI number, but taller.
  • DRBEF4824MTANMC and DRBEF4824STANMC: 4-ton N-coils, same 24-1/2 in width; one step down in capacity.
  • DRBEF4821STANMC: 4-ton N-coil, with no published width.
  • DRBEF4821HTAAMC and DRBEF4821STAAMC: 4-ton A-coils.
  • DRBEF4221HTAAMC and DRBEF4221STAAMC: 3.5-ton A-coils.
  • DRBEF3624MTANMC: 3-ton N-coil, 24-1/2 in wide.

The rule is simple: if the house calls for five tons and the furnace height is limited, this DRBEF6024HTANMC is the natural candidate. If it calls for four tons, the DRBEF4824 models are more appropriate.

A few situations where the N-coil is the answer

A basement finished with a dropped ceiling is the most frequent case. But there are others: a furnace installed under a staircase, a blower cabinet in a closet or a utility space, a piping run that reduces the usable height. In each of these situations, a few centimetres gained in the cabinet decide whether the project is feasible. We measure the available height, compare it with that of the cabinet and tell you honestly whether the model fits.

Who is it a good choice for?

For the owner of a large home who wants to cool every room with the existing ducts, who accepts replacing the outdoor unit at the same time as the coil and who wants to keep the furnace as backup heat. Less relevant if the height under the furnace is generous: the lighter A-coil version then becomes simpler to install. Also less relevant if the house does not need five tons: a smaller size costs less and runs more quietly.

Built-in detector and warranty

A box installed at the factory on models without the L suffix combines an A2L sensor and a mitigation board. If excess refrigerant is detected, the outdoor unit pauses. Any 24 V thermostat will do (CDS-228 sheet). The manufacturer offers a conditional 10-year parts warranty, with registration.

What our installation includes

AirGreen is a family-run heating and cooling company in Montreal for more than fifteen years, under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.

  • measuring the furnace, the blower and the electrical panel;
  • installing the coil, insulated transition if needed, sealed joints;
  • outdoor unit on a stand, brazed piping, nitrogen test, vacuum;
  • condensate drain and thermostat;
  • start-up, airflow adjustment, training at your home.

A word on summer comfort

With a large size, the temptation is to believe that bigger means cooler. In reality, a system that cools too fast shuts off before it has dried the air, and the house stays clammy. The point of good sizing, confirmed by the visit, is precisely to get longer cycles and better humidity control. The coil, by collecting the condensation water in its pan, contributes directly to this.

Rebates

Eligibility depends on the matched system, not on the coil alone, and on the installation date. We verify Hydro-Québec's official list at the time of the quote and tell you what applies to your project.

Ask for your estimate

We come to measure for free: furnace, electrical service, available height. You then receive a written quote for the complete Durastar system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF6024HTANMC sits in the plenum of a furnace or air handler. Connected to a matching Durastar outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with a matching Durastar outdoor unit
Certified systemRatings belong to the certified match; we confirm the AHRI number before ordering.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF6024HTANMC
TypeCased evaporator coil
LineDRBEF
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D24-1/2 in
Net weight100 lb
Model numberDRBEF6024HTANMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.