DURASTAR DRBEF4824STANMC Evaporator N-Coil | 4 Tons

In stock

The Durastar DRBEF4824STANMC 4-ton R-454B cased coil sits on your furnace and, matched with the Durastar DRHP15B42AJ2AN outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF4824STANMC

4 tons48,000 BTU/h nominal
24-1/2 inwidth
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216686805
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF4824STANMC
ManufacturerDurastar
Size4 tons
Width24-1/2 in
RefrigerantR-454B
MeteringTXV
Outdoor unitDRHP15B42AJ2AN

DRBEF4824STANMC: a 4-ton N-coil, two possible outdoor units and three AHRI numbers

Most coils are sold with a single matching story. This one has several. The Durastar DRBEF4824STANMC evaporator coil is an N-shaped, cased model of 4 tons (48,000 BTU/h), 24-1/2 in wide, using R-454B refrigerant. The sheet mentions two outdoor units, the DRHP15B42AJ2AN and the DRHP14B42AJ2AN, as well as three certification numbers. This page teaches you how to read that sheet, whether you live in Montreal, Laval, Longueuil, on the North Shore or on the South Shore.

Reading the matching sheet

Here is what the DRBEF4824STANMC sheet states: matched outdoor units, DRHP15B42AJ2AN, DRHP14B42AJ2AN; system AHRI numbers, 216686805, 216686807, 216686737; SEER2 of 15.2 for the system, with the cold-climate certification described below. In concrete terms, each AHRI number corresponds to a specific combination of coil and outdoor unit; it is a certificate, not a decoration. We cannot tell you here which of the three numbers goes with which of the two units: we confirm it in the directory before ordering, so that the paperwork and the equipment correspond.

Why insist on this number

Imagine two quotes that advertise the same efficiency. One cites an AHRI number, the other does not. The first lets you verify; the second asks you to believe. The number is also the key that opens the rebate lists: without it, there is no way to know whether the match is eligible.

A match designed for the cold

Durastar publishes this coil among the cold-climate certified matches, with the DRHP15B42AJ2AN: (HSPF2 8.1, 40,000 BTU/h at -8 °C). It is one of the two models designated this way, along with the DRBEF4821STANMC. It also appears, as "4824S", in the list of standard-efficiency TXV coils listed on ENERGY STAR, with ratings published for the US market.

The furnace stays in place. It keeps its blower, its filters and its ducts, and takes over below a threshold set with you when the outdoor temperature plunges.

The N shape and the 24-1/2 in width

The N is a coil with three faces in a zigzag, installed in a cabinet lower than that of an A-coil. You choose it when height is lacking above the furnace. Its 24-1/2 in width must agree with that of the plenum; if not, an insulated transition is built on site. The cabinet is delivered insulated, ready to install. The stated positions: upflow, downflow, horizontal left or right. The TXV regulates the refrigerant flow.

The net weight is 83 lb. Two 3/4 in NPT condensate connections, and 3/8 in and 7/8 in connections for the refrigerant piping.

How to choose between the DRBEF4824STANMC and its four-ton neighbours

  • DRBEF4824MTANMC: same shape, same width, but heavier and with no single published outdoor unit; for those who want to choose freely.
  • DRBEF4821STANMC: 4-ton N-coil, matched to the DRHP15B42AJ2AN only, lighter, with no published width.
  • DRBEF4821HTAAMC and DRBEF4821STAAMC: A-coils, taller.

And compared with the other sizes: DRBEF3624MTANMC for three tons; DRBEF4221HTAAMC and DRBEF4221STAAMC for three and a half tons; DRBEF6021STAAMC and DRBEF6024HTANMC for five tons.

Our advice: if your furnace has the 24-1/2 in width and you want a cold-climate certified system with a choice between two outdoor units, this is the model to look at.

What a coil does, in two sentences

In summer, the refrigerant evaporates in its tubes, absorbs heat from the air and leaves the moisture in the pan. In winter, with a heat pump, the cycle reverses and heat is passed to the air of the house.

Which match to choose, the DRHP15B42AJ2AN or the DRHP14B42AJ2AN?

Both outdoor units belong to the family of Durastar R-454B heat pumps with a two-stage compressor. Only the DRHP15B42AJ2AN is expressly cited in this coil's cold-climate certified match. If winter heating is your priority, that is therefore the one we look at first. The other option keeps its place if availability, installation space or the layout of your lot justify it; we discuss it during the visit and verify the combination in the directory before placing the order.

One coil, three documents to ask for

Whoever the supplier is, ask for three things: the AHRI number of the proposed system, the exact part number of the outdoor unit and confirmation of the plenum width against the coil's 24-1/2 in. With those three items, you have what you need to compare quotes without relying on a slogan. We provide this information in writing with every quote.

And what about the furnace?

It keeps its role. Its blower pushes air through the coil, its filters catch dust and its ducts serve each room. If you are moving from an electric furnace to a heat pump, it lightens the bill in the mild season; if you keep a gas furnace, it becomes backup heat for the harshest days.

Safety and warranty

The refrigerant detector, a box combining an A2L sensor and a mitigation board, is installed at the factory on models without the L suffix. It pauses the outdoor unit if there is excess refrigerant and accepts any 24 V thermostat (CDS-228 sheet). The manufacturer's warranty is conditional, 10 years on parts, with registration.

Our work, from measurement to training

AirGreen is a family-run heating and cooling company in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.

  • measuring the furnace, the blower and the panel;
  • installing the coil, insulated transition if needed, sealed joints;
  • outdoor unit installed, brazed piping, nitrogen test, vacuum;
  • condensate drain and thermostat;
  • start-up, airflow adjustment, explanations.

How long does such a system last in service?

We avoid lifespan promises that the manufacturer does not publish. What we do know is that a well-installed system, with tight piping, a careful vacuum and a tuned airflow, ages better than a system installed in a hurry. The conditional 10-year parts warranty, with registration, provides a framework; our role is to make sure you never have to use it. An annual check before the cooling season is a good habit to take up.

LogisVert rebate

The matched Durastar system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We verify it on the official list at the time of the quote and put the application together with you.

Ask for your estimate

We stop by your home at no charge, measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread out the cost.

01 · What it is for

The heat pump coil for your furnace

The DRBEF4824STANMC sits in the plenum of a furnace or air handler. Connected to the Durastar DRHP15B42AJ2AN outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Durastar DRHP15B42AJ2AN outdoor unit
Certified systemMatched with the DRHP15B42AJ2AN, the system carries AHRI 216686805.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF4824STANMC
TypeCased evaporator coil
LineDRBEF
Nominal size4 tons (48,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Dimensions W × H × D24-1/2 in
Net weight83 lb
Matched outdoor unitDRHP15B42AJ2AN, DRHP14B42AJ2AN
System AHRI number216686805, 216686807, 216686737
System SEER2 / HSPF215.2 / 8.1
Model numberDRBEF4824STANMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • The coil is 24-1/2 in wide; we check the furnace before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 4-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.