DURASTAR DRBEF6021STAAMC Evaporator A-Coil | 5 Tons

In stock

The Durastar DRBEF6021STAAMC 5-ton R-454B cased coil sits on your furnace and, matched with the Durastar DRHP14B60AJ2AN outdoor unit, makes a central system that cools and, with a heat pump, heats your home.

Model numberDRBEF6021STAAMC

5 tons60,000 BTU/h nominal
casedtype
R-454Brefrigerant
R-454BAdd-on heat pumpCasedAHRI 216686623
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberDRBEF6021STAAMC
ManufacturerDurastar
Size5 tons
RefrigerantR-454B
MeteringTXV
Outdoor unitDRHP14B60AJ2AN

DRBEF6021STAAMC: five tons in an A-coil, the large size of the DRBEF series, for big homes

At the top of the range is the big coil. The DRBEF6021STAAMC is a Durastar A-shaped, cased evaporator coil with a nominal size of 5 tons (60,000 BTU/h) and R-454B refrigerant. It is designed to install on a furnace or a blower cabinet, and to pair with the DRHP14B60AJ2AN outdoor unit. In Montreal, Laval, Longueuil, on the North Shore as on the South Shore, the homes that call for this size are not the most numerous, but they are the ones where a wrong choice costs the most.

Five tons: what are we talking about?

Sixty thousand BTU/h is the largest size in the series. It is aimed at large homes, multi-storey residences, open-plan layouts with high ceilings and houses with a long glazed façade. Capacity alone is not enough: at this size, the coil needs a considerable airflow, and the furnace blower must be up to it. We check this before proposing this model, and we are the first to advise a smaller size if the ducts or the blower cannot keep up.

The A, the two-sided shape

Two sloped faces that meet at the top, like a roof: the air rises into the centre and passes through both planes. It is the classic shape for upflow furnaces. It demands height, and for a five-ton size, that is a point to examine first. If the basement ceiling is low, its N version is the DRBEF6024HTANMC, 24-1/2 in wide.

The cabinet is insulated and delivered ready to install. Net weight: 76 lb, which is less than its N-coil cousin. Published positions: upflow, downflow, horizontal left or right. The metering device is a TXV. The connections: 3/8 in (liquid), 7/8 in (suction), and two 3/4 in NPT condensate connections.

The outdoor partner: the DRHP14B60AJ2AN

The manufacturer's sheet lists, for this coil, the DRHP14B60AJ2AN outdoor unit and the AHRI numbers 216686623, 216686621. The published ratings of the system are a SEER2 of 15.2 and an HSPF2 of 7.8. This system is not one of the series' two cold-climate certified matches: it is another configuration, for another size of home.

The coil has no efficiency rating of its own. It is the system's figures, tied to an AHRI number, that matter when comparing quotes. We verify this number in the directory before ordering.

What the coil does in the house

It cools the air in summer by absorbing its heat and moisture, and with a heat pump, it heats in winter by passing to the air the heat captured outdoors. The furnace keeps its blower, its filters and its ducts, and takes over below a threshold programmed with you. For a large home, that is a valuable advantage: the backup heat is already there, sized for the whole dwelling.

Five tons or four? A question of airflow

Between the four-ton and five-ton sizes, the difference is not limited to capacity. The larger coil needs more heat-exchange surface, therefore more airflow, therefore a suitable blower and ducts. Here are the neighbours to consider:

  • DRBEF6024HTANMC: 5-ton N-coil, 24-1/2 in wide, heavier; for a low ceiling.
  • DRBEF4821HTAAMC and DRBEF4821STAAMC: 4-ton A-coils, same profile as this one.
  • DRBEF4821STANMC, DRBEF4824MTANMC, DRBEF4824STANMC: 4-ton N-coils.
  • DRBEF4221HTAAMC and DRBEF4221STAAMC: 3.5-ton A-coils.
  • DRBEF3624MTANMC: 3-ton N-coil.

The DRBEF6021STAAMC is part of, under code 6021S (A), the standard-efficiency TXV coils that Durastar lists as ENERGY STAR, with ratings published for the US market.

An example home for five tons

Think of a large two-storey home on the North Shore with a full basement, a kitchen open to the living room and windows across the whole back façade. In summer, the afternoon sun heats the main floor and the upstairs stays stifling. A window unit fixes nothing, and a smaller system runs out of breath. This is the kind of home for which a five-ton size is worth discussing, provided the blower and the ducts keep up. We never start from floor area alone: we look at the windows, the insulation, the exposure and the air distribution system.

What we check for this size

Three points come up every time. First, the blower: can it move the required airflow without excessive noise? Second, the air returns: are they wide enough to feed the furnace? Third, the electrical panel: does it have the room and the capacity for the outdoor unit? If any of these points fails, we propose a correction or another size, even if it reduces the value of the sale. A large house that is poorly equipped stays uncomfortable, whatever the size of the coil.

Leak detector, thermostat, warranty

A single box, installed at the factory on models without the L suffix, contains an A2L sensor and a mitigation board. It pauses the outdoor unit if refrigerant builds up in excess, and it works with any 24 V thermostat (CDS-228 sheet). The manufacturer's warranty is conditional, 10 years on parts, with registration.

How we proceed

AirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For a system of this size, we insist on three points: the blower, the air returns and the electrical panel.

  • visit: measuring the furnace, assessing the blower, the duct system and the panel;
  • installing the coil in the plenum, insulated transition if needed, sealed joints;
  • outdoor unit on a base or stand, brazing, nitrogen leak test, vacuum;
  • connecting the drain and the thermostat;
  • start-up, airflow adjustment and explanations.

To check before choosing

  • The coil only installs with an outdoor unit using the same refrigerant, installed at the same time.
  • The ratings apply to the certified match, with the DRHP14B60AJ2AN.
  • The furnace width must match; we verify it on site.
  • The blower must provide the airflow this size requires.

LogisVert rebate

The matched Durastar system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation: we verify it on the official list when we prepare the quote and put the application together with you.

Ask for your estimate

On site, at no charge: we measure the furnace, check the electrical service and give you a written quote for the complete Durastar system. Financing is available to spread the cost of the project.

01 · What it is for

The heat pump coil for your furnace

The DRBEF6021STAAMC sits in the plenum of a furnace or air handler. Connected to the Durastar DRHP14B60AJ2AN outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.

  • Turning an electric furnace into a central heat pump
  • Replacing an old central air conditioner with a new system
  • Keeping the furnace as backup heat for the coldest nights
  • Pairing with the Durastar DRHP14B60AJ2AN outdoor unit
Certified systemMatched with the DRHP14B60AJ2AN, the system carries AHRI 216686623.
On your furnaceThe blower, filters and existing ducts are kept.
R-454B refrigerantThe coil and outdoor unit are installed together, on the same refrigerant.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDurastar
ModelDRBEF6021STAAMC
TypeCased evaporator coil
LineDRBEF
Nominal size5 tons (60,000 BTU/h)
RefrigerantR-454B
Metering deviceTXV
Liquid connection3/8 in
Suction connection7/8 in
Net weight76 lb
Matched outdoor unitDRHP14B60AJ2AN
System AHRI number216686623, 216686621
System SEER2 / HSPF215.2 / 7.8
Model numberDRBEF6021STAAMC
03 · Before installing

What to know before installing

  • R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
  • The coil has no efficiency rating of its own; published ratings belong to the matched system.
  • We check the furnace width before ordering.
  • The blower must deliver the system airflow.
  • Grants depend on the complete system; we confirm eligibility for the installation date.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Evaporator coils
See all
Same brand
DURASTAR
See all
06 · Questions

Frequently asked questions

Can this coil heat?

Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.

Can I keep my current air conditioner?

Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.

Does it qualify for grants?

Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.

My furnace is a different width. What are my options?

We measure the furnace and build an insulated transition on site if needed.

Is the furnace still useful?

Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 5-ton Durastar coil, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on November 26, 2026.