DURASTAR DRBEF4821STANMC Evaporator N-Coil | 4 Tons
The Durastar DRBEF4821STANMC 4-ton R-454B cased coil sits on your furnace and, matched with the Durastar DRHP15B42AJ2AN outdoor unit, makes a central system that cools and, with a heat pump, heats your home.
Model numberDRBEF4821STANMC
514 316-2973 · sales@airgreen.ca
Quick facts
DRBEF4821STANMC: the 4-ton N-coil, matched to face the Quebec winter
Most coils come with a capacity and a shape. This one arrives with a named partner: the DRHP15B42AJ2AN outdoor unit. The Durastar DRBEF4821STANMC evaporator coil, N-shaped, cased, with a nominal size of 4 tons (48,000 BTU/h) and R-454B refrigerant, is one of the two matches that Durastar publishes as certified for cold climates. For a home in Montreal, Laval, Longueuil, the North Shore or the South Shore where the thermometer stays below zero for weeks, that detail changes how you read the spec sheet.
What "cold climate" means here
In the manufacturer's documentation, the match of the DRBEF4821STANMC with the DRHP15B42AJ2AN heat pump shows (HSPF2 8.1, 40,000 BTU/h at -8 °C). These values describe the system, not the coil alone. The SEER2 published for this system is 15.2. The AHRI numbers that correspond to this combination are 216686804, 216686811.
Why do these numbers matter? Because they link a specific coil to a specific outdoor unit. It is the only way to prove, in a public directory, that the advertised ratings really apply to what is installed in your home.
A heat pump that works in winter, a furnace that stands watch
Even with a match certified for the cold, the furnace does not disappear. It keeps its blower, its filters and its ducts, and it stays ready to take over the heating when the outdoor temperature drops below the threshold we program with you. This division of labour, the heat pump for most of the season and the furnace for the harshest nights, is what makes the project reasonable for a home that is already equipped.
If you currently heat with electricity, the difference is telling. An electric furnace converts each kilowatt-hour into an equivalent amount of heat. A heat pump moves heat from outdoors, and in mild weather provides roughly two to three times the energy it consumes; that efficiency drops with the cold, which is why a match designed for low temperatures is worth having.
Why the N shape?
Three faces in a zigzag, in a cabinet less tall than that of an A-coil. It is the solution when the space above the furnace is restricted: a beam, piping, a finished ceiling. The insulated cabinet is delivered ready to install. The positions allowed by the manufacturer are: upflow, downflow, horizontal left or horizontal right. The TXV regulates the refrigerant flow.
This model is the lightest of its size: 71 lb net weight, less than each of the other 4-tons. The connections are 3/8 in (liquid) and 7/8 in (suction), with two 3/4 in NPT condensate connections.
A width to confirm
Unlike the DRBEF4824 models, this coil has no published width in our sheet. So we measure the furnace during the visit and confirm that the plenum is suitable. If needed, an insulated transition is built on site.
DRBEF4821STANMC or DRBEF4824STANMC?
Both are 4-ton N-coils, both are certified for cold climates, and both appear in Durastar's standard-efficiency ENERGY STAR list (4821S and 4824S), with ratings published for the US market. Here is what sets them apart:
- the DRBEF4821STANMC weighs 71 lb and is matched to the DRHP15B42AJ2AN;
- the DRBEF4824STANMC shows a width of 24-1/2 in, weighs more and offers two outdoor unit options, the DRHP15B42AJ2AN or the DRHP14B42AJ2AN.
If you are looking for the lightest option to handle and your furnace allows it, this is the one. If you want a known width and more matching choices, look at the other.
Compared with the other sizes in the series
- 3 tons: DRBEF3624MTANMC, N-coil, 24-1/2 in wide.
- 3.5 tons: DRBEF4221HTAAMC and DRBEF4221STAAMC, A-coils.
- 4 tons as A-coils: DRBEF4821HTAAMC and DRBEF4821STAAMC.
- 4 tons as N-coils: DRBEF4824MTANMC in addition to the DRBEF4824STANMC.
- 5 tons: DRBEF6021STAAMC as an A-coil, DRBEF6024HTANMC as an N-coil.
Why cold changes the choice of system
Here, winter is not an average: it is a succession of icy mornings, thaws and setbacks. A heat pump whose spec sheet only talks about mild temperatures leaves you guessing what happens when the mercury plunges. A match whose heating output is published at -8 °C gives you, by contrast, a concrete reference that you can compare from one quote to the next. It is not a guarantee that your home will stay comfortable in extreme cold, but it is a solid basis for discussion, and we use it to decide with you on the threshold for switching to the furnace.
An example home for this coil
Think of an expanded bungalow in Longueuil, with a gas or electric furnace in the basement, a finished ceiling that is a little low and a cooling need that grows each summer. Four tons suits this size of house when the ducts are in good shape, and the N shape avoids sacrificing space. The match certified for the cold is reassuring for winter, and the furnace is still there for the extreme moments. This is the kind of home we have in mind when we recommend this model.
Leak detector and warranty
A box installed at the factory on models without the L suffix contains an A2L sensor and a mitigation board. It stops the outdoor unit if there is excess refrigerant, and it suits any 24 V thermostat (CDS-228 sheet). The manufacturer offers a conditional 10-year parts warranty, with registration.
Our way of installing
AirGreen is a family-run heating and cooling company, based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For this system, we proceed as follows:
- measuring the furnace, checking the blower and the electrical panel;
- coil in the plenum, insulated transition if needed, sealed joints;
- outdoor unit on a base or stand, brazed piping, nitrogen test, vacuum;
- connecting the drain and the thermostat;
- start-up, airflow adjustment and explanations at your home.
To check before committing
- The coil only works with an outdoor unit using the same refrigerant, installed at the same time.
- The ratings apply to the certified match, so to the DRHP15B42AJ2AN, and not to another unit.
- The furnace blower must provide the airflow this size requires.
LogisVert rebate
The matched Durastar system appears on Hydro-Québec's list of eligible heat pumps. The amount varies according to the installation date and your situation: we verify it on the official list when we prepare the quote and put the application together with you.
Ask for your estimate
Book a free visit: we measure the furnace, check the electrical supply and leave you a written quote for the complete Durastar system. Financing lets you spread the cost of the project.
The heat pump coil for your furnace
The DRBEF4821STANMC sits in the plenum of a furnace or air handler. Connected to the Durastar DRHP15B42AJ2AN outdoor unit, it cools in summer and, with a heat pump, heats in winter through the existing ductwork.
- Turning an electric furnace into a central heat pump
- Replacing an old central air conditioner with a new system
- Keeping the furnace as backup heat for the coldest nights
- Pairing with the Durastar DRHP15B42AJ2AN outdoor unit
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- R-454B refrigerant: the coil is matched with an outdoor unit on the same refrigerant.
- The coil has no efficiency rating of its own; published ratings belong to the matched system.
- We check the furnace width before ordering.
- The blower must deliver the system airflow.
- Grants depend on the complete system; we confirm eligibility for the installation date.
Manufacturer documents
Explore the range
Evaporator coilsSee allSame brand
DURASTARSee all
Frequently asked questions
Can this coil heat?
Yes, when matched with a heat pump: it cools in summer and heats in winter. With a central air conditioner it only cools.
Can I keep my current air conditioner?
Usually not. The coil runs on R-454B and must be matched with the outdoor unit specified by the manufacturer. We install the complete system.
Does it qualify for grants?
Eligibility depends on the matched system, not the coil alone. We check Hydro-Québec's official list for the installation date.
My furnace is a different width. What are my options?
We measure the furnace and build an insulated transition on site if needed.
Is the furnace still useful?
Yes. It keeps its blower and serves as backup heat when the outdoor temperature drops below the set point we program with you.
A 4-ton Durastar coil, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on November 26, 2026.