LG

LG Multi F MAX LGRED R32 Heat Pump | 2 Heads + 36000 BTU | Montérégie

In stock
SKU: KUMXA361A
36,000BTU/h · 2 heads
−25 °Cheats down to
$3,552LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientWi-Fi includedR-32Up to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit KUMXA361APossible indoor models KNUAK091A, KNUAK121A, NUAK181A, KNMAB071A, KNUAB091A, KNUAB121A, KNMAB151A, KNUAB181A, KNMAB241AAHRI 215402345· ENERGY STAR 3621279
In short

The LG Multi F Max LGRED R32 36 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 29,600 BTU/h at −8 °C, heats down to −25 °C and qualifies for a $3,552 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Compared with the 141 multi-zone systems of 36,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 389367AHRI 215402345LogisVert · October 1, 2026
+EER2 14.5Rank 5 (tied) of 138. Class median: 12.0.
+HSPF2 11.0Rank 9 (tied) of 141. Class median: 10.0.
+Only 55 dB(A) outdoorsRank 7 (tied) of 141. Class median: 61 dB(A).
!Good to know: indoor head from 29 dB(A)Rank 73 of 134; class median: 28 dB(A).
29,600BTU/h certified at −8 °C
−25 °Cstill heating
2 → 5heads, on the same unit
2.38COP at −8 °C
$3,552LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KUMXA361A

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads and modulates from 12,420 to 49,600 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones7 zones8 zones
36,000BTU
Here345
42,000BTU
23456
48,000BTU
2345678

LG Multi F Max LGRED R32 36 000 · 2 zones

29,600 BTU/h
at −8 °C
$3,552
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 115 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
12,420 → 50,000 BTU/h
-8 °C
14,880 → 49,600 BTU/h
-15 °C
13,392 → 45,000 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling22.0
Scale 1 – 30Median: 21
Rank 45 (tied) of 141 in its class.
HSPF2 · seasonal heating11.0
Scale 1 – 15Median: 10
Rank 9 (tied) of 141 in its class.
EER2 · cooling in peak heat14.5
Scale 1 – 20Median: 12
Rank 5 (tied) of 138 in its class.
COP at −15 °C1.89
Scale 0 – 4Median: 1.9
Rank 73 (tied) of 118 in its class.
ENERGY STAR Most EfficientCold climate · ID 3621279 · ENERGY STAR database
09 · LogisVert grant

A grant you can calculate, not guess.

29,600 BTU/h÷ 1,000 ×$120=$3,552

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215402345). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 141 multi-zone systems of 36,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

11 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

12 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$3,552 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

13 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

54.34 in
KUMXA361ADepth 15.34 in
37.41 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
40 A max. breaker
MCA 33 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 33 A, 40 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
14 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

29
38
55
28
61
20 dB(A)3040506070
29 Reference head, lowest speed38 Reference head, highest speed28 Class indoor median55 Outdoor unit61 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
15 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
49,600BTU/h peak at −8 °CIts maximum capacity certified by NEEP, above its rated value.
12,420BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−25 °CColdest certified pointNEEP still lists 35,900 BTU/h at a COP of 1.87 at −13 °F.
120 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
675R-32 GWPGlobal warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
16 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTUSheet
Certified cooling at 35 °C36,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)22.0AHRI
EER2 (instant cooling efficiency)14.5AHRI
HSPF2 (seasonal heating efficiency, region IV)11.0AHRI
HSPF2, region V (coldest)9.8NEEP
Heating
Capacity at +8.3 °C45,000 BTU/h · COP 4NEEP
Capacity at −8 °C29,600 BTU/h · COP 2.38NEEP
Capacity at −15 °C41,500 BTU/h · COP 1.89NEEP
Capacity at −25 °C (max.)35,900 BTU/h · COP 1.87NEEP
Modulation range12,420 – 49,600 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product2 Zones (Dual Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsKNUAK091A, KNUAK121A, NUAK181A, KNMAB071A, KNUAB091A, KNUAB121A, KNMAB151A, KNUAB181A, KNMAB241ASheet
Indoor dimensions (W × D × H)32.94 x 7.56 x 12.13 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)459 CFMSheet
Indoor sound (reference head)29 – 38 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.41 x 15.34 x 54.34 inSheet
Outdoor sound55 dB(A)Sheet
Base pan heater120 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)33 ASheet
MOP (maximum overcurrent protection)40 ASheet
RefrigerantR-32Sheet
Wi-FiIncludedSheet
Certifications and warranty
AHRI215402345AHRI
ENERGY STARYes · cold climate · ID 3621279ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$3,552LogisVert
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
17 · Official brochures

The manufacturer’s documentation, as PDF.

18 · Description

Everything we have written about this system.

A multi-zone solution designed for the residential and multi-unit realities of the Montérégie region

At AirGreen Heat Pumps, Air Conditioning & Heating , we have been installing multi-zone systems for many years in a wide variety of settings: single-family homes, duplexes, triplexes, new condos, major renovations, and multi-unit buildings. The LG Multi F MAX LGRED R32 | 2 Heads + 36,000 BTU Heat Pump is one of the solutions we recommend when flexibility, winter performance, and precise comfort control are top priorities, particularly in the Montérégie region , Longueuil , the South Shore , and as far north as the South Shore .

This system is based on a simple logic: a high-performance outdoor unit capable of powering several independent indoor units, while maintaining excellent energy efficiency, even during periods of intense cold typical of the Quebec climate.


Understanding the Multi F MAX architecture: why this system stands out

The LG Multi F MAX LGRED R32 is not a typical wall-mounted heat pump. It is an advanced multi-zone system, designed to distribute heating and cooling power precisely where it is needed.

A robust and intelligent outdoor unit

The KUMXA361A outdoor unit offers a nominal capacity of 36,000 BTU , with an operating range that remains stable down to -25°C in heating mode . In practice, this means the system continues to provide reliable comfort even during the prolonged cold spells we regularly experience in Montreal , Laval , Longueuil , and the Montérégie region .

Thanks to LGRED technology combined with R-32 gas , this heat pump offers:

  • Improved seasonal energy efficiency

  • A reduction in the environmental burden

  • Increased performance stability in extreme conditions

The electrical parameters, current management (MCA 33 A, MOP 40 A) and internal design are suitable for serious residential installations, without compromising on safety or durability.

Two zones today, up to five tomorrow

Although this configuration is shown with 2 indoor units , the system allows for up to 5 zones in total. This scalability is particularly advantageous in projects where:

  • A renovation is planned in several phases

  • A basement or secondary dwelling will be created at a later date.

  • The owner wants to maintain room for expansion.

We have installed this type of configuration in several properties on the South Shore , where needs are evolving rapidly with family or rental projects.


Indoor units: targeted comfort, precise control

One of the major advantages of a multi-zone system lies in the independent management of each space . Compatible indoor units (including the KNUAK , KNUAB and KNMAB series) allow the power, airflow and airflow direction to be adapted according to the actual use of each room.

A comfort that is noticeable on a daily basis

In the residences we have equipped in Boucherville , Saint-Hubert and Saint-Lambert , the occupants quickly notice:

  • A more stable temperature

  • Fewer abrupt variations between rooms

  • A reduction in overheated or underheated areas

The internal noise level , which can go down to around 29 dB(A) depending on the model chosen, makes these units perfectly suited for bedrooms, home offices and open living spaces.

Air direction and diffusion quality

Automatic motorized louvers , both horizontal and vertical, ensure even air distribution. This limits direct drafts, an often overlooked but essential point for real comfort, especially during prolonged heating.


Energy efficiency: beyond the numbers, real savings

The seasonal efficiency values ​​announced for this system are high, but at AirGreen , we always insist on the concrete interpretation of this data.

What this means for a homeowner in Montérégie

In real-world projects that we have followed over several heating seasons:

  • Electricity consumption is more stable

  • Demand peaks are better controlled.

  • Comfort is maintained without frequent recourse to supplementary sources

The high COP at -8°C indicates the system's ability to produce more heat per kilowatt consumed, even when the outside temperature drops. This is a key factor for homeowners concerned about their long-term operating costs.


HVAC installation: a determining factor often underestimated

A system like the LG Multi F MAX LGRED R32 doesn't tolerate approximations. The quality of the HVAC installation directly influences the performance, reliability, and lifespan of the equipment.

Refrigeration network management

Adherence to maximum pipe lengths, permitted elevation differences, and refrigerant distribution is essential. In multi-story buildings or multi-unit dwellings, we pay particular attention to:

  • The location of the outdoor unit

  • The routing of the main and secondary pipes

  • Reducing pressure losses

These elements are crucial to ensuring that each indoor unit receives the intended capacity, without imbalance.

An approach tailored to each building

Every installation we carry out in Montreal , Laval , Longueuil , or on the South Shore begins with a precise analysis of heating and cooling needs, building configuration, and occupancy patterns. This approach allows us to fully exploit the potential of an advanced multi-zone system.


Concrete scenarios encountered by AirGreen

Intergenerational home in Longueuil

In a residence comprising a main dwelling and an intergenerational space, the LG Multi F MAX enabled:

  • Independent control of the two areas

  • A reduction in comfort conflicts between occupants

  • Simplified HVAC maintenance

Renovated duplex in Montérégie

For a renovated older duplex, choosing a multi-zone system avoided the installation of multiple outdoor units, improving both aesthetics and municipal compliance.


LogisVert subsidy and energy compliance

This model is eligible for the LogisVert provincial subsidy , with an amount of up to $3,552 depending on the applicable conditions. We systematically support our clients in:

  • Validation of eligibility

  • Preparing the required documents

  • Compliance with technical requirements


Why entrust your project to AirGreen

Choosing AirGreen means benefiting from:

  • With recognized expertise in multi-zone HVAC installation

  • Transparent pricing , confirmed before work begins

  • Certified refrigeration technicians experienced with advanced LG systems

  • $5 million in liability insurance

Our field experience allows us to anticipate real constraints and avoid costly mistakes that we see too often on poorly planned multi-zone installations.


Conclusion

The LG Multi F MAX LGRED R32 | 2 Heads + 36,000 BTU Heat Pump represents a high-level solution for homeowners in Montérégie , Montreal , Laval , Longueuil , the North Shore and the South Shore who are looking for a reliable, scalable system perfectly suited to the Quebec climate.

For a detailed quote , a personalized analysis , or advice on integrating this system into your property, contact AirGreen Heat Pumps, Air Conditioning & Heating directly. Our team will be happy to assist you at every stage of your HVAC project.

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.

19 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 29,600 BTU/h at −8 °C, 41,500 at −15 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$3,552 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3621279. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 29 dB(A). Outdoors, 55 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $3,552AHRI 215402345 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 389367 (AHRI 215402345): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 3621279.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.