LG

LG Multi F MAX LGRED R32 Heat Pump | 4 Heads at 48,000 BTU | Montérégie

In stock
SKU: KUMXA481A
48,000BTU/h · 4 heads
−25 °Cheats down to
$4,200LogisVert, indicative
ENERGY STAR® cold climateENERGY STAR Most EfficientWi-Fi includedR-32Up to 8 heads
Talk to a technician · 514 316-2973
Outdoor unit KUMXA481APossible indoor models KNUAK091A, KNUAK121A, NUAK181A, KNMAB071A, KNUAB091A, KNUAB121A, KNMAB151A, KNUAB181A, KNMAB241AAHRI 215408636· ENERGY STAR 3621305
In short

The LG Multi F Max LGRED R32 48 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. it delivers 35,000 BTU/h at −8 °C, heats down to −25 °C and qualifies for a $4,200 LogisVert grant. Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

4 rooms, one outdoor unit.

Compared with the 82 multi-zone systems of 48,000 BTU we sell. Every number on this page carries its source.

ENERGY STAR Most EfficientNEEP 389330AHRI 215408636LogisVert · October 1, 2026
+EER2 13.1Rank 1 (tied) of 78. Class median: 12.0.
+HSPF2 10.5Rank 15 (tied) of 78. Class median: 10.0.
!Good to know: SEER2 20.5Rank 54 of 78; class median: 21.3.
35,000BTU/h certified at −8 °C
−25 °Cstill heating
4 → 8heads, on the same unit
2.47COP at −8 °C
$4,200LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KUMXA481A

Outdoor unit

One compressor for the whole house. It supplies up to 8 heads and modulates from 12,420 to 56,500 BTU/h depending on what the rooms call for (NEEP).

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones7 zones8 zones
36,000BTU
2345
42,000BTU
23456
48,000BTU
23Here5678

LG Multi F Max LGRED R32 48 000 · 4 zones

35,000 BTU/h
at −8 °C
$4,200
LogisVert

Up to 8 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 100 % of its rated capacity.

Tap a temperature: certified capacity, efficiency and the cost of one hour of heating.

It slows down, it speeds up: the certified modulation range

Light bar: from minimum to maximum capacity. Dark mark: the rated value.

+8.3 °C
12,420 → 59,000 BTU/h
-8 °C
16,950 → 56,500 BTU/h
-15 °C
15,255 → 52,500 BTU/h
Source: NEEP, minimum, rated and maximum ratings at 47, 17 and 5 °F.
07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification. The mark shows the median of the same-size multi-zone systems we sell.

SEER2 · seasonal cooling20.5
Scale 1 – 30Median: 21.3
Rank 54 (tied) of 78 in its class.
HSPF2 · seasonal heating10.5
Scale 1 – 15Median: 10
Rank 15 (tied) of 78 in its class.
EER2 · cooling in peak heat13.1
Scale 1 – 20Median: 12
Rank 1 (tied) of 78 in its class.
COP at −15 °C2.09
Scale 0 – 4Median: 2
Rank 22 (tied) of 71 in its class.
ENERGY STAR Most EfficientCold climate · ID 3621305 · ENERGY STAR database
09 · LogisVert grant

A grant you can calculate, not guess.

35,000 BTU/h÷ 1,000 ×$120=$4,200

The capacity at −8 °C comes from Hydro-Québec’s list of October 1, 2026. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215408636). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Report card

Where it ranks among same-size multi-zone systems.

Compared with the 82 multi-zone systems of 48,000 BTU we sell, using the LogisVert list figures. Weaknesses too, said plainly.

11 · Head-to-head

Against three other brands in its class.

Same rated size, other manufacturers. Pick the opponent.

12 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone4 wall units
On the wall1 outdoor unit4 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,200 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

13 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

54.34 in
KUMXA481ADepth 15.34 in
37.41 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
40 A max. breaker
MCA 34 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Head 4
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 34 A, 40 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
14 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

29
38
56
28
64
20 dB(A)3040506070
29 Reference head, lowest speed38 Reference head, highest speed28 Class indoor median56 Outdoor unit64 Class outdoor median
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
15 · What sets it apart

What is particular about this machine.

Only facts published by ENERGY STAR, NEEP or the manufacturer.

Most EfficientENERGY STARAmong the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
56,500BTU/h peak at −8 °CIts maximum capacity certified by NEEP, above its rated value.
12,420BTU/h at low speedMinimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
−25 °CColdest certified pointNEEP still lists 39,200 BTU/h at a COP of 1.92 at −13 °F.
120 WBase pan heaterHeater in the outdoor unit’s base pan, against ice (NEEP).
675R-32 GWPGlobal warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
16 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTUSheet
Certified cooling at 35 °C48,000 BTU/hNEEP
SEER2 (seasonal cooling efficiency)20.5AHRI
EER2 (instant cooling efficiency)13.1AHRI
HSPF2 (seasonal heating efficiency, region IV)10.5AHRI
HSPF2, region V (coldest)8.5NEEP
Heating
Capacity at +8.3 °C52,500 BTU/h · COP 3.62NEEP
Capacity at −8 °C35,000 BTU/h · COP 2.47NEEP
Capacity at −15 °C48,000 BTU/h · COP 2.09NEEP
Capacity at −25 °C (max.)39,200 BTU/h · COP 1.92NEEP
Modulation range12,420 – 56,500 BTU/hNEEP
Heats down to−25 °CSheet
Zones and heads
Zones on this product4 Zones (Quad Zone)Sheet
Maximum zones8 ZonesSheet
Possible indoor modelsKNUAK091A, KNUAK121A, NUAK181A, KNMAB071A, KNUAB091A, KNUAB121A, KNMAB151A, KNUAB181A, KNMAB241ASheet
Indoor dimensions (W × D × H)32.94 x 7.56 x 12.13 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)459 CFMSheet
Indoor sound (reference head)29 – 38 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.41 x 15.34 x 54.34 inSheet
Outdoor sound56 dB(A)Sheet
Base pan heater120 WNEEP
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)34 ASheet
MOP (maximum overcurrent protection)40 ASheet
RefrigerantR-32Sheet
Wi-FiIncludedSheet
Certifications and warranty
AHRI215408636AHRI
ENERGY STARYes · cold climate · ID 3621305ENERGY STAR
ENERGY STAR Most EfficientYesENERGY STAR
LogisVert grant (indicative)$4,200LogisVert
Warranty (compressor · parts · labour)10 yrs · 10 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
17 · Official brochures

The manufacturer’s documentation, as PDF.

18 · Description

Everything we have written about this system.

A multi-zone solution designed for the demanding buildings of the Montérégie region

At AirGreen , we have been installing HVAC systems for many years in a wide variety of settings: single-family homes, semi-detached houses, multi-unit residential buildings, and light commercial buildings. The LG Multi F MAX LGRED R32 heat pump with 4 indoor units and a nominal capacity of 48,000 BTU is perfectly suited to this regional reality: compartmentalized buildings, varying comfort needs in different areas, outdoor space constraints, and high energy requirements.

In the Montérégie region , we often encounter projects where a single outdoor unit needs to supply multiple spaces: ground floor and upper floor, enclosed offices, commercial spaces with technical areas, or even apartments where each occupant wants independent control. This is precisely the area where this advanced multi-zone system is ideally suited.

Multi F MAX LGRED Architecture: what truly distinguishes this system

An outdoor unit designed for intensive multi-zone use

The heart of the system is the LG Multi F MAX LGRED R32 outdoor unit – model KUMXA481A – capable of powering up to 8 indoor units , including 4 simultaneously in the configuration shown here. Unlike traditional residential multi-split systems, this platform originates from the light commercial sector, with:

  • a variable-speed scroll compressor designed to operate over wide load ranges

  • a much more precise electronic refrigerant management (EEV) system

  • a high tolerance for pipe lengths and level differences between units

These features are essential in South Shore buildings, where pipe runs are rarely simple and the outdoor unit is not always installed directly behind each indoor head.

R-32 refrigerant: technical and regulatory choice

R-32 is not a marketing ploy for AirGreen; it's a logical technical choice. This refrigerant offers:

  • improved thermodynamic efficiency compared to R-410A

  • a lower total load for the same capacity

  • a reduced global warming potential (GWP) , in line with regulatory guidelines in Quebec

In our facilities in Montérégie , this point is particularly relevant for new or renovated buildings aiming for better overall energy performance.

Indoor units: adapt each zone to its actual use

A full range of power outputs

One of the major advantages of the LG Multi F MAX is the flexibility in choosing indoor units. Depending on the configuration selected, we can install wall-mounted units of:

  • 9,000 BTU

  • 12,000 BTU

  • 14,300 BTU

  • 18,000 BTU

This allows for precise adjustment of capacity for each room: bedroom, office, open-plan area, retail space, or meeting room. In practice, this approach avoids two common errors that we often correct in existing systems:

  • Oversizing , a source of discomfort and short cycles

  • Undersizing , which forces the device to operate continuously

Acoustic comfort and air diffusion

The wall units compatible with this system are designed to operate quietly , even under partial load. In residential projects in the Montérégie region , this is a key criterion, particularly for:

  • bedrooms

  • home offices

  • care or consultation areas

Automatic control of the shutters (horizontal and vertical) allows for homogeneous air distribution, limiting localized cold or hot zones.

Heating performance: a crucial point for Quebec's climate

Reliable heating in cold weather

The LG Multi F MAX LGRED is designed to maintain stable heating capacity down to -25°C , which corresponds to the climatic realities of the Montérégie region . In our projects, this translates to:

  • a primary heating system for many buildings

  • a marked reduction in the use of backup systems

It is important to point out that, on this type of advanced multi-zone system, seasonal performance indicators must be interpreted correctly: the priority is capacity stability and intelligent load management , rather than isolated theoretical figures.

Real example in Montérégie

During a recent installation in a multi-unit residential building in Saint-Jean-sur-Richelieu , we replaced several independent systems with an LG Multi F MAX 48,000 BTU unit with four separate zones. Results observed after a full season:

  • stable temperature in each dwelling

  • Significant reduction in service calls

  • better control of energy costs for the owner

HVAC Installation: Why Expertise Makes All the Difference

Piping and bypass unit management

This type of system requires advanced expertise in HVAC installation :

  • compliance with maximum pipe lengths

  • managing height differences between units

  • correct installation of distribution units (BDUs) when required

At AirGreen, our refrigeration technicians plan each piping network before even arriving on site. This preparation significantly reduces the risk of imbalances between zones and guarantees long-lasting performance.

Common mistakes to avoid

We regularly work on poorly installed multi-zone systems. The most common problems are:

  • Inadequate choice of power levels per zone

  • non-optimized pipe lengths

  • lack of reflection on the future evolution of the building

An improperly sized LG Multi F MAX loses many of its advantages. That's why we always insist on a complete analysis before any installation in Montérégie , the South Shore , or the North Shore .

LogisVert subsidy: an important financial lever

At the time of writing, this system is eligible for a provincial LogisVert grant of up to $4,200 , depending on the final configuration and building type. For many projects in the Montérégie region , this financial assistance makes a real difference in the decision to invest in a high-quality, multi-zone system.

We systematically support our clients in:

  • eligibility verification

  • the preparation of the required documents

  • the technical conformity of the installation

Why choose AirGreen for this LG system?

Choosing an LG Multi F MAX LGRED R32 is an important technical decision. Choosing AirGreen to install it is just as important. Our customers trust us for:

  • our field experience in multi-zone HVAC

  • our ability to operate in Montérégie , Montreal , Laval , Longueuil , South Shore and North Shore

  • the transparency of our recommendations and our offers

Each project is treated as a bespoke system, never as a simple standard installation.

A solution truly suited to today's buildings

The LG Multi F MAX LGRED R32 heat pump – 4 heads, 48,000 BTU – is designed for homeowners and managers looking for:

  • maximum flexibility per zone

  • proven reliability in cold climates

  • a scalable HVAC solution, capable of adapting to future changes

In Montérégie , it is one of the most coherent systems for combining comfort, performance and control.

Contact AirGreen

For a complete analysis , a detailed quote , or a technical visit , contact AirGreen Heat Pumps, Air Conditioning & Heating . We will guide you toward the configuration best suited to your building and your energy objectives.

Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.

19 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 35,000 BTU/h at −8 °C, 48,000 at −15 °C.

How many heads can I connect?

Up to 8 on this outdoor unit. This product is configured for 4 heads.

How much is the LogisVert grant?

$4,200 according to Hydro-Québec’s list of October 1, 2026. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3621305. It also meets the ENERGY STAR Most Efficient criteria, according to the ENERGY STAR database.

Down to what temperature does it heat?

Down to −25 °C.

Is it noisy?

Indoors, the reference head goes down to 29 dB(A). Outdoors, 56 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 10 years on the compressor and 10 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,200AHRI 215408636 checked against the list of October 1, 2026
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
Sources checked on October 1, 2026.NEEP, Cold Climate Air Source Heat Pump List, product 389330 (AHRI 215408636): capacities and COP, modulation, SEER2, EER2, HSPF2.ENERGY STAR certified heat pump database, ID 3621305.Hydro-Québec, LogisVert eligible heat pump list (owner, existing home), file of October 1, 2026; participation guide, version 1.10.Costs: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.