GE RAK149F2A Wired Wall Thermostat for Zoneline PTAC
The genuine GE wall thermostat that controls a Zoneline PTAC from the wall instead of the unit’s own panel.
AirGreen codeAG-PT-002
514 316-2973 · sales@airgreen.ca
Quick facts
The GE RAK149F2A wall thermostat controls a Zoneline PTAC from the room’s wall. It is wired, non-programmable and powered at 24 V by the unit. It handles cooling, heat pump heating and electric heat, with two fan speeds.
A simple wall control for Zoneline PTACs
Placed away from the air discharge, the thermostat reads the room’s actual temperature better than the unit’s panel. In heat pump mode, it works in two stages: the compressor first, then electric heat when the setpoint is not reached. GE specifies that all Zoneline applications are type B heat pumps.
Manufacturer specifications
- R, C, Y, W, O/B, GL and GH terminals
- Power supply of 20 to 30 V AC, class 2, 50/60 Hz
- Setpoint from 16 to 29 °C (60 to 85 °F), display in °F or °C, backlit screen
- 5-minute delay against compressor short cycling, in the installer menu
- Dimensions: 3-3/4 × 6 × 1-1/8 in
Before installation
The thermostat is designed for low voltage only: a higher voltage will damage it. The PTAC must be set for wall thermostat control, according to its manual. Send us your unit’s full model number: we confirm compatibility before ordering.
Installed by AirGreen across Greater Montréal
We install the thermostat, run the control wire to the PTAC and set up the unit in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with your unit model and the quantity.
Control the PTAC where people actually live
Mounted on the wall, the thermostat reads the room temperature and runs the unit over a wire.
- Zoneline heat pump PTACs, with electric heat as second stage
- Zoneline cooling PTACs with electric heat
- Hotel rooms, residences and apartments that need a simple wall control
- Replacing an existing GE wall thermostat
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- GE states that all Zoneline applications are B-type heat pumps (O/B terminal).
- The thermostat wires to the unit’s R, C, Y, W, O/B, GL and GH terminals.
- Low voltage only: anything above 30 V damages the thermostat.
- The PTAC must be set for wall thermostat control: follow the unit’s manual.
You may also need
LCDI Power Cord for GE Zoneline PTAC (RAK315P, RAK320P)
14/4 Communication Cable for Heat Pumps
Aluminum Exterior Grille for PTAC
PTAC Drain Kit
Power Cord for Gree 230 V PTAC
Gree TP-N-631 Wired Wall Thermostat for PTACPTAC partsSee all
Frequently asked questions
Will it work with my PTAC?
GE presents it for Zoneline applications, heat pump or cooling with electric heat. Send us your unit’s full model number and we confirm before ordering.
Is it programmable?
No. You set the temperature, mode and fan speed at the thermostat, with no schedule.
Do I need the C wire?
The C (24 V common) terminal is on the base. Among other things, it lets the display light stay on all the time.
Can you install it?
Yes. We mount the thermostat, run the wire to the unit and set up the PTAC, everywhere in Greater Montréal.
A genuine wall thermostat for your GE PTAC
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.