Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
A slim ducted unit, concealed in the ceiling or at floor level.
The 9,000 and 12,000 BTU/h DLFSDA body is only 7.87 in (200 mm) thick. Pick the model and the mounting: you see the space it takes, its static pressure and its heat at -15 °C.
Where does the ducted unit hide, and how much room does it take?
Tap your model and the mounting. Measurements come from the manufacturer’s catalogue; heat from ENERGY STAR, NEEP or the catalogue, as shown under each result.
Your ducted unit
Mounting
Body thickness printed by the manufacturer
The three D5FSDA (R-454B) have no printed dimensions in our documents. Size and location are decided at the visit, with the existing or new ductwork.
Horizontal mounting, concealed in the ceiling: the body is 7.87 in (200 mm) thick, on 27.56 × 19.92 in.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410433); maximum at -30 °C listed by NEEP (record 406550). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Vertical mounting allowed by the manufacturer: a built-in secondary drain pan lets the unit stand upright, concealed at floor or ceiling level depending on the space.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410433); maximum at -30 °C listed by NEEP (record 406550). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Horizontal mounting, concealed in the ceiling: the body is 7.87 in (200 mm) thick, on 27.56 × 19.92 in.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410431); maximum at -30 °C listed by NEEP (record 406548). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Vertical mounting allowed by the manufacturer: a built-in secondary drain pan lets the unit stand upright, concealed at floor or ceiling level depending on the space.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410431); maximum at -30 °C listed by NEEP (record 406548). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Horizontal mounting, concealed in the ceiling: the body is 8.27 in (210 mm) thick, on 34.65 × 26.54 in.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410428); maximum at -30 °C listed by NEEP (record 406545). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Vertical mounting allowed by the manufacturer: a built-in secondary drain pan lets the unit stand upright, concealed at floor or ceiling level depending on the space.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410428); maximum at -30 °C listed by NEEP (record 406545). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Horizontal mounting, concealed in the ceiling: the body is 9.8 in (249 mm) thick, on 43.31 × 30.47 in.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410426 / 3996283); maximum at -30 °C listed by NEEP (record 406543). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Vertical mounting allowed by the manufacturer: a built-in secondary drain pan lets the unit stand upright, concealed at floor or ceiling level depending on the space.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 2410426 / 3996283); maximum at -30 °C listed by NEEP (record 406543). LogisVert amount to be confirmed: only Hydro-Québec confirms the amount granted.
Horizontal mounting, concealed in the ceiling: the body is 9.80 in (249 mm) thick, on 53.54 × 30.47 in.
Its outdoor unit, the DLCLRBH36AAK, is in neither of the manufacturer’s two catalogues: we confirm the pairing and its ratings before the quote. No LogisVert amount on our product sheet. Only Hydro-Québec confirms the amount granted.
Vertical mounting allowed by the manufacturer: a built-in secondary drain pan lets the unit stand upright, concealed at floor or ceiling level depending on the space.
Its outdoor unit, the DLCLRBH36AAK, is in neither of the manufacturer’s two catalogues: we confirm the pairing and its ratings before the quote. No LogisVert amount on our product sheet. Only Hydro-Québec confirms the amount granted.
Horizontal mounting, concealed in the ceiling: the body is 11.81 in (300 mm) thick, on 47.24 × 34.41 in.
Values printed in the 2018 catalogue (p. 52) for this pairing, which it lists as not ENERGY STAR certified. It is not on the NEEP list. No LogisVert amount on our product sheet. Only Hydro-Québec confirms the amount granted.
Vertical mounting allowed by the manufacturer: a built-in secondary drain pan lets the unit stand upright, concealed at floor or ceiling level depending on the space.
Values printed in the 2018 catalogue (p. 52) for this pairing, which it lists as not ENERGY STAR certified. It is not on the NEEP list. No LogisVert amount on our product sheet. Only Hydro-Québec confirms the amount granted.
Horizontal mounting, concealed in the ceiling: the body is 17.32 in (440 mm) thick, on 55.12 × 33.78 in.
Values printed in the 2018 catalogue (p. 52) for this pairing, which it lists as not ENERGY STAR certified. It is not on the NEEP list. No LogisVert amount on our product sheet. Only Hydro-Québec confirms the amount granted.
The manufacturer does not allow vertical mounting for the 58,000: horizontal only.
Values printed in the 2018 catalogue (p. 52) for this pairing, which it lists as not ENERGY STAR certified. It is not on the NEEP list. No LogisVert amount on our product sheet. Only Hydro-Québec confirms the amount granted.
The documents we hold list the D5FSDA as a slim ducted unit for the manufacturer’s R-454B heat pumps, without printing its dimensions or the allowed mountings: we confirm them before the quote.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 3556055); maximum at -30 °C listed by NEEP (record 391053). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.
The documents we hold list the D5FSDA as a slim ducted unit for the manufacturer’s R-454B heat pumps, without printing its dimensions or the allowed mountings: we confirm them before the quote.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 3556055); maximum at -30 °C listed by NEEP (record 391053). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.
The documents we hold list the D5FSDA as a slim ducted unit for the manufacturer’s R-454B heat pumps, without printing its dimensions or the allowed mountings: we confirm them before the quote.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 3556062); maximum at -30 °C listed by NEEP (record 391046). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.
The documents we hold list the D5FSDA as a slim ducted unit for the manufacturer’s R-454B heat pumps, without printing its dimensions or the allowed mountings: we confirm them before the quote.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 3556062); maximum at -30 °C listed by NEEP (record 391046). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.
The documents we hold list the D5FSDA as a slim ducted unit for the manufacturer’s R-454B heat pumps, without printing its dimensions or the allowed mountings: we confirm them before the quote.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 3556067); maximum at -30 °C listed by NEEP (record 391041). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.
The documents we hold list the D5FSDA as a slim ducted unit for the manufacturer’s R-454B heat pumps, without printing its dimensions or the allowed mountings: we confirm them before the quote.
Heat at -8 and -15 °C, SEER2 and HSPF2 certified by ENERGY STAR (no. 3556067); maximum at -30 °C listed by NEEP (record 391041). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.
All 10 ARCOAIRE ducted units, right below.
Each product gives the indoor unit, its outdoor unit, the AHRI number and, when there is one, the indicative LogisVert amount. Pricing by quote.
Ten ducted units, two formats: slim up to 24,000, light commercial above.
The measurements the manufacturer prints for each indoor unit. Static pressure says how hard the unit can push air through the ducts.
| Indoor unit | Size (W × H × D) | Net weight | Max. static pressure | Airflow (low / med / high) | Sound (low / med / high) | |
|---|---|---|---|---|---|---|
| DLFSDA · R-410A | ||||||
| 9,000 BTU/h DLFSDAH09XAK + DLCSRBH09AAK | 27.56 × 7.87 × 19.92 in 700 × 200 × 506 mm | 43.56 lb (19.8 kg) | 0.20 in W.C. | 147 / 211 / 264 CFM | 30 / 34 / 38 dB(A) | |
| 12,000 BTU/h DLFSDAH12XAK + DLCSRBH12AAK | 27.56 × 7.87 × 19.92 in 700 × 200 × 506 mm | 43.56 lb (19.8 kg) | 0.20 in W.C. | 176 / 282 / 353 CFM | 35 / 37 / 39 dB(A) | |
| 18,000 BTU/h DLFSDAH18XAK + DLCSRBH18AAK | 34.65 × 8.27 × 26.54 in 880 × 210 × 674 mm | 54 lb (24.5 kg) | 0.40 in W.C. | 300 / 400 / 480 CFM | 35 / 37 / 39 dB(A) | |
| 24,000 BTU/h DLFSDAH24XAK + DLCSRBH24AAK | 43.31 × 9.8 × 30.47 in 1,100 × 249 × 774 mm | 86.86 lb (39.4 kg) | 0.64 in W.C. | 440 / 700 / 780 CFM | 35.5 / 40 / 44 dB(A) | |
| DLFLDA · R-410A · light commercial | ||||||
| 36,000 BTU/h DLFLDAH36XAK + DLCLRBH36AAK | 53.54 × 9.80 × 30.47 in 1,360 × 249 × 774 mm | 106.48 lb (48.3 kg) | 0.64 in W.C. | 700 / 910 / 1,080 CFM | 38.5 / 42 / 45.5 dB(A) | |
| 48,000 BTU/h DLFLDAH48XAK + DLCLRAH48AAK | 47.24 × 11.81 × 34.41 in 1,200 × 300 × 874 mm | 119.71 lb (54.3 kg) | 0.64 in W.C. | 720 / 1,030 / 1,230 CFM | 46 / 49.5 / 50.5 dB(A) | |
| 58,000 BTU/h DLFLDAH58XAK + DLCLRAH58AAK | 55.12 × 17.32 × 33.78 in 1,400 × 440 × 858 mm | 163 lb (74 kg) | 0.80 in W.C. | 1,260 / 1,710 / 2,150 CFM | 51 / 54 / 57 dB(A) | |
| D5FSDA · R-454B | ||||||
| D5FSDA 12,000, 18,000 and 24,000 | not published | not published | not published | not published | not published | |
DLFSDA: catalogue DLS-001-AR-01 (March 2024), p. 29. DLFLDA: same catalogue, p. 59; the exact models are DLFLDAH36XAK, DLFLDAH48XAK and DLFLDAH58XAK. The 2018 catalogue (328-32-0499-00, p. 58) prints the same values. A 1 in (25.4 mm) drain on every printed size. Static pressure in inches of water column.
Seven ENERGY STAR cold-climate certified systems; the three DLFLDA are not.
The heat certified by ENERGY STAR Canada and the coldest point listed by NEEP, for each system sold on this page.
| System | Max. at -15 °C | Coldest listed point | SEER2 | HSPF2 (region IV) | AHRI | ENERGY STAR Canada | Indicative LogisVert | |
|---|---|---|---|---|---|---|---|---|
| DLFSDA · R-410A | ||||||||
| 9,000 BTU/h DLFSDAH09XAK + DLCSRBH09AAK | 10,800 BTU/h | 5,000 BTU/h at -30 °C | 20.2 | 12.0 | 206350383 | 2410433 | to be confirmed | |
| 12,000 BTU/h DLFSDAH12XAK + DLCSRBH12AAK | 12,100 BTU/h | 5,500 BTU/h at -30 °C | 19.5 | 10.0 | 206350385 | 2410431 | to be confirmed | |
| 18,000 BTU/h DLFSDAH18XAK + DLCSRBH18AAK | 17,700 BTU/h | 9,000 BTU/h at -30 °C | 18.0 | 9.5 | 206350388 | 2410428 | to be confirmed | |
| 24,000 BTU/h DLFSDAH24XAK + DLCSRBH24AAK | 27,000 BTU/h | 11,000 BTU/h at -30 °C | 19.2 | 10.5 | 206350391 | 2410426 / 3996283 | to be confirmed | |
| D5FSDA · R-454B | ||||||||
| 12,000 BTU/h D5FSDAH12XAK + D5CSHAH12AAK | 11,800 BTU/h | 6,400 BTU/h at -30 °C | 20.0 | 10.2 | 215324115 | 3556055 | $1,152 | |
| 18,000 BTU/h D5FSDAH18XAK + D5CSHAH18AAK | 18,000 BTU/h | 9,000 BTU/h at -30 °C | 18.0 | 10.8 | 215324122 | 3556062 | $1,800 | |
| 24,000 BTU/h D5FSDAH24XHK + D5CSHAH24AAK | 24,000 BTU/h | 10,200 BTU/h at -30 °C | 19.2 | 11.7 | 215324127 | 3556067 | $2,592 | |
| DLFLDA · R-410A | ||||||||
| 36,000 BTU/h DLFLDAH36XAK + DLCLRBH36AAK | not listed | not listed | not listed | not listed | 208685657 | not certified | none on our sheets | |
| 48,000 BTU/h DLFLDAH48XAK + DLCLRAH48AAK | not listed | not listed | not listed | not listed | 201835522 | not certified | none on our sheets | |
| 58,000 BTU/h DLFLDAH58XAK + DLCLRAH58AAK | not listed | not listed | not listed | not listed | 201835523 | not certified | none on our sheets | |
The 48,000 and 58,000 DLFLDA are paired with DLCLRA outdoor units: the 2018 catalogue (p. 52) lists them as not ENERGY STAR certified and prints 34,000 and 35,000 BTU/h maximum at -15 °C, SEER 17.4 and 18.0 (older ratings). The 36,000 DLFLDA is paired with the DLCLRBH36AAK, which is in neither catalogue. The four DLFSDA, ENERGY STAR cold-climate certified, carry no LogisVert amount on our sheets: amounts to be confirmed.
Three ways the ducted unit adapts to your home.
A secondary drain pan lets the unit stand vertically.
Thanks to its built-in secondary drain pan, the DLFSDA can be mounted upright, concealed at floor or ceiling level depending on the space. So can the DLFLDA, in 36,000 and 48,000.
Catalogue DLS-001-AR-01, 03/2024, pp. 28 and 58A programmable wall controller comes in the box.
With the DLFSDA, the manufacturer supplies the KSACN0701AAA wired wall controller, 7-day programmable, on top of the wireless remote.
Catalogue DLS-001-AR-01, 03/2024, p. 28The return air connects at the rear or from below.
On the DLFSDA, and on the 36,000 and 48,000 DLFLDA, the manufacturer allows both return-air positions: we choose from the duct route.
Catalogue DLS-001-AR-01, 03/2024, pp. 28 and 58What people ask us about ducted units.
Ducted unit or central heat pump?
A ducted unit serves one or a few rooms through short ducts; its maximum static pressure runs from 0.20 to 0.80 in W.C. depending on the size. A central heat pump connects to a full duct system. We look at your ducts and rooms at the visit before choosing.
Is the condensate pump included?
Yes on the DLFSDA and the DLFLDA: a built-in pump lifts the water up to 29.5 in (750 mm) above the unit. For the D5FSDA, our documents do not say: we check before the quote.
Is it quiet?
The manufacturer prints 30 to 38 dB(A) for the 9,000 DLFSDA, from low to high fan speed, and 51 to 57 dB(A) for the 58,000 DLFLDA.
Is Wi-Fi possible?
Yes, with the optional KSAIF0401AAA kit, made for ducted units of every size. A 24 V interface for another brand’s thermostat disables the Wi-Fi module.
What about LogisVert?
It is indicative and taken from our product sheets: $1,152, $1,800 and $2,592 for the 12,000, 18,000 and 24,000 D5FSDA. The DLFSDA amounts are to be confirmed; the DLFLDA carry none. Only Hydro-Québec confirms the amount granted.
How do you choose the size?
At the visit: the rooms to serve, their windows and insulation, then the route and length of the ducts. The unit’s static pressure has to be enough for that duct run.
A hidden unit, ducts checked before the quote.
We find the spot for the unit, the route of the ducts and grilles, then choose the size. You get a quote with the system and its AHRI number.
Sources checked on October 29, 2026
- ARCOAIRE, ductless catalogue DLS-001-AR-01 (March 2024), pp. 28, 29, 58, 59 and 69: DLFSDA, DLFLDA, Wi-Fi kit.
- ARCOAIRE, ductless catalogue 328-32-0499-00 (May 2018), pp. 52 and 58 (printed page numbers): DLFLDA with DLCLRA.
- ARCOAIRE, Deluxe Series brochure DLS-030-AR-02 (June 2026), p. 4: compatible indoor units, including the D5FSDA.
- NEEP cold-climate heat pump list, records 406550, 406548, 406545, 406543, 391053, 391046, 391041, modified August 24, 2026, read October 28, 2026.
- ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market (DLFSDAH09XAK 2410433, DLFSDAH12XAK 2410431, DLFSDAH18XAK 2410428, DLFSDAH24XAK 2410426/3996283, D5FSDAH12XAK 3556055, D5FSDAH18XAK 3556062, D5FSDAH24XHK 3556067), read October 28, 2026.
- airgreen.ca product sheets (indicative LogisVert amounts), re-read October 29, 2026.
LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.