AirGreenARCOAIRE
AirGreen × ARCOAIRE · Floor-ceilingOne unit for a large open roomSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full ARCOAIRE range
  1. Home
  2. ARCOAIRE
  3. Floor-ceiling
ARCOAIRE floor-ceiling unit · Updated October 29, 2026

On the floor or the ceiling: one unit for a large open space.

The manufacturer prints a 39 ft (12 m) air throw for the 48,000 and the 58,000. Pick the size and the room length: you see whether the jet reaches the far end, and the maximum heat listed by NEEP at -15 °C.

3sizes: 36,000, 48,000 and 58,000 BTU/h
9.25 inthick (235 mm), all three
-30 °Cheating limit printed for the DLCLRC outdoor unit
1 to 1one indoor unit per outdoor unit, never multi-zone
01 · The size

Which size, and how far does the air carry?

Heat comes from NEEP; the air throw from the manufacturer’s 2024 catalogue (p. 63).

Unit size

Room length

Air throw printed by the manufacturer

36,000 BTU/hprinted air throw
33 ft (10 m)
48,000 BTU/hprinted air throw
39 ft (12 m)
58,000 BTU/hprinted air throw
39 ft (12 m)

The air throw says how far the jet carries, not the room size the unit heats. The size is decided at the visit, from the room, the windows and the insulation.

48,000 BTU/h · DLFLFAH48XAK + DLCLRCH48AAK
35,000BTU/h max. at -15 °C

The jet carries 39 ft (12 m): it reaches the far end of a 33 ft room.

Rated heat at -8 °C29,000 BTU/h
Maximum at -25 °C19,000 BTU/h
SEER2 · HSPF218.9 · 10.0
Indicative LogisVert$3,480

Values as listed by NEEP (record 405418). LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.

The shop

All 3 ARCOAIRE floor-ceiling units, right below.

Each product gives the indoor unit, the DLCLRC outdoor unit, the AHRI number and, when there is one, the indicative LogisVert amount. Pricing by quote.

ARCOAIRE
02 · Dimensions

Slim throughout: 9.25 in thick, from the 36,000 to the 58,000.

The values the manufacturer prints for the DLFLFA indoor unit. The 48,000 and the 58,000 share the same cabinet.

Indoor unitSize (W × H × D)Net weightAirflow (low / med / high)Sound (low / med / high)Air throw
DLFLFA · R-410A
36,000 BTU/h
DLFLFAH36XAK
50.59 × 9.25 × 26.57 in
1,285 × 235 × 675 mm
69 lb (31.3 kg)638 / 917 / 1,037 CFM43 / 49 / 54 dB(A)33 ft (10 m)
48,000 BTU/h
DLFLFAH48XAK
64.96 × 9.25 × 26.57 in
1,650 × 235 × 675 mm
83.78 lb (38 kg)1,000 / 1,120 / 1,350 CFM52 / 54 / 57 dB(A)39 ft (12 m)
58,000 BTU/h
DLFLFAH58XAK
64.96 × 9.25 × 26.57 in
1,650 × 235 × 675 mm
110 lb (50 kg)796 / 1,029 / 1,385 CFM46 / 49 / 55 dB(A)39 ft (12 m)

Ductless catalogue DLS-001-AR-01 (March 2024), p. 63. A 1 in (25.4 mm) drain on all three sizes; the catalogue mentions no condensate pump for this unit.

03 · The outdoor unit

A dedicated DLCLRC outdoor unit, heating printed down to -30 °C.

Each floor-ceiling unit connects to its own DLCLRC outdoor unit of the same size, never to a multi-zone outdoor unit.

Outdoor unitHeating rangeTotal piping · liftSuction lineMinimum circuit ampacity (MCA)Outdoor sound
DLCLRC · R-410A
36,000 BTU/h
DLCLRCH36AAK
-22 to 86 °F
-30 to 30 °C
213 ft (65 m) · 98 ft (30 m)5/8 in (16 mm)30 A63.0 dB(A)
48,000 BTU/h
DLCLRCH48AAK
-22 to 86 °F
-30 to 30 °C
213 ft (65 m) · 98 ft (30 m)5/8 in (16 mm)35 A62.5 dB(A)
58,000 BTU/h
DLCLRCH58AAK
-22 to 86 °F
-30 to 30 °C
213 ft (65 m) · 98 ft (30 m)7/8 in (22 mm)35 A61.2 dB(A)

Catalogue DLS-001-AR-01, p. 53 (outdoor unit) and p. 63 (pairing). For the 58,000, the suction line is printed 7/8 in on the outdoor side (p. 53) and 5/8 in on the indoor side (p. 63): we confirm it at the visit. In NEEP, the coldest point listed for these three systems is -13 °F (-25 °C): that is the value shown in the tool. For the 48,000 and the 58,000, the catalogue (p. 55) prints 28,000 and 30,000 BTU/h maximum at -15 °C, below NEEP’s 35,000 and 34,400: we show NEEP.

Did you know

Three details of the floor-ceiling unit, as the manufacturer prints them.

39 ft

The 48,000 and the 58,000 throw air 39 ft.

That is the throw the manufacturer prints; the 36,000 reaches 33 ft (10 m).

Catalogue DLS-001-AR-01, 03/2024, p. 63
9.25 in

Only 9.25 in thick, whatever the size.

All three are the same 235 mm thick (the manufacturer’s H dimension); only the width changes, from 50.59 to 64.96 in.

Catalogue DLS-001-AR-01, 03/2024, p. 63
“L”

The L in DLFLFA stands for “light commercial”.

In the manufacturer’s code, the 4th letter gives the series: L for Light Commercial. These units come from the light-commercial range, installed here in homes and shops.

Catalogue DLS-001-AR-01, 03/2024, p. 71 (model decoder)
04 · Questions

What people ask us about floor-ceiling units.

Floor or ceiling: what difference does it make?

The manufacturer allows both for the same unit. On the ceiling it frees the floor; on the floor it sits under a window. We choose from the room and the line-set route, at the visit.

Can it connect to a multi-zone outdoor unit?

No. The catalogue pairs it only with the DLCLRC outdoor unit of the same size: 36 with 36, 48 with 48, 58 with 58.

Does it need a condensate pump?

The catalogue mentions no built-in pump for this unit; the drain is 1 in. If the water cannot drain by gravity, we include a pump in the quote.

Is it loud?

The manufacturer prints 43 to 54 dB(A) for the 36,000, 52 to 57 for the 48,000 and 46 to 55 for the 58,000, from low to high fan speed. It is a unit for a large volume: it blows harder than a bedroom wall head.

What about LogisVert?

Only the 48,000 carries one on our sheets: $3,480, indicative. It is the only one of the three that is ENERGY STAR cold-climate certified. Only Hydro-Québec confirms the amount granted.

How do you choose the size?

At the visit: floor area, ceiling height, windows, insulation and how the room is used. The air throw then helps place the unit so the jet covers the room.

AirGreen × ARCOAIRE

A large space, one unit in the right place.

We measure the room, choose the size and the mounting, floor or ceiling, then give you a quote with the system and its AHRI number.

RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
Free on-site estimateSize and mounting are decided at your home, once we have seen the room, the ceiling and the electrical panel.
Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.

Sources checked on October 29, 2026

  1. ARCOAIRE, ductless catalogue DLS-001-AR-01 (March 2024), pp. 53, 55, 62, 63 and 71: DLCLRC, DLFLFA, ratings and model decoder.
  2. NEEP cold-climate heat pump list, records 405421, 405418, 404565, modified August 24, 2026, read October 28, 2026.
  3. ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market (DLFLFAH48XAK 2416054), read October 28, 2026.
  4. airgreen.ca product sheets (indicative LogisVert amount), re-read October 29, 2026.

LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.