AirGreenLENNOX
LENNOX · MERIT · VARIX · VARIX EXTREME · VARIX MINIThe LENNOX space at AirGreenSold and installed by AirGreen in Montréal, Laval, Longueuil, on the South Shore and the North Shore.
All of LENNOX
R-410A · earlier generationUpdated October 28, 2026
MPBLENNOX wall unit · R-410A

The MPB and the MLA take the same wall head. Here is what the outdoor unit changes.

Same MWMA head, two LENNOX outdoor units on R-410A. At all four sizes, the MPB has the better HSPF rating; the MLA gives more heat in the cold and heats down to -30 °C, the MPB to -25 °C. Pick a size: we put both LENNOX tables side by side.

4sizes in our catalogue9,000 → 24,000 BTU/h
-25 °CLENNOX heating range (-13 °F)Bulletin 210863, Dec. 2020
MWMAthe same head as the MLA, at all four sizesLENNOX bulletins 210863 and 210861
12 yearsparts and compressor in QuébecEW900011-01, installed since March 1, 2017
The shop

The 4 MPB sizes, right below

From 9,000 to 24,000 BTU/h, in 208/230 V, with an MWMA wall head. Open a product page for the AHRI number and dimensions.

AirGreenLENNOX
01 · Same head, another outdoor unit

The same MWMA head on the wall: MPB or MLA outside

LENNOX publishes an AHRI rating for each outdoor unit with the same head, and a heating table for each (21 °C indoors). Pick a size, and everything compares.

Size

Table: total heat printed by LENNOX at 21 °C indoors, bulletins 210863 (MPB, December 2020) and 210861 (MLA, May 2021). The MPB has no row below -25 °C: that is the limit of its heating range. AHRI rating: standard test, at 8.3 and -8.3 °C.

Below the panel: the full sheet of both, line by line, at the same size.

MPB 12,000 or MLA 12,000, on the same head

MPB012S4S-1P or MLA012S4S-1P · head MWMA012S4-3P

MPB 12,000 · -15 °C9,130BTU/hLENNOX table 210863
MLA 12,000 · -15 °C12,100BTU/hLENNOX table 210861

At -15 °C, the MLA gives 2,970 BTU/h more, 33% more, with the same head on the wall.

MPB, LENNOX tableMLA, LENNOX table

AHRI ratings at -8.3 °C: 7,700 for the MPB, 7,800 for the MLA, almost the same: it is in the tables, in the cold, that the MLA pulls ahead.

The MPB heats down to -25 °C (-13 °F), the MLA to -30 °C (-22 °F). At Montréal-Trudeau, about 12 nights a year drop below -20 °C.

Open the MPB 12,000 page · The MLA page

MPB 12,0002nd generation · R-410A
MLA 12,000Low ambient · R-410A
Indoor headMWMA012S4-3P
Indoor headMWMA012S4-3P
Generation (letter in the number)2nd (B)
Generation (letter in the number)1st (A)
Heats down to-25 °C (-13 °F)
Heats down to-30 °C (-22 °F)
Cools down to (outdoors)-25 °C (-13 °F)
Cools down to (outdoors)-30 °C (-22 °F)
Rated cooling (AHRI)12,000 BTU/h
Rated cooling (AHRI)12,000 BTU/h
Rated heating 8.3 · -8.3 °C12,000 · 7,700
Rated heating 8.3 · -8.3 °C12,000 · 7,800
SEER · EER · HSPF22.7 · 13.7 · 11
SEER · EER · HSPF22 · 12.5 · 10
Outdoor sound55 dB(A), cooling and heating
Outdoor sound52 dB(A) cooling · 57 heating
Max. piping · height82 ft · 33 ft
Max. piping · height82 ft · 33 ft
Circuit: MCA · MOCP12 · 15 A
Circuit: MCA · MOCP9 · 15 A
Outdoor weight (net)77 lb
Outdoor weight (net)88 lb
Factory R-410A charge2 lb 9 oz
Factory R-410A charge3 lb 3 oz
LENNOX warranty in Québec12 years parts and compressor
LENNOX warranty in Québec12 years parts and compressor
AHRI201796631
AHRI201796633

Pink rows are the differences. LENNOX bulletins 210863 (December 2020) and 210861 (May 2021); warranty: EW900011-01, for an installation on or after March 1, 2017. Both series are rated in SEER and HSPF: these numbers compare with each other. The MLA page.

02 · Did you know

Three things the LENNOX documents say about the MPB

2022

LENNOX filed the MPB under “old” in July 2022

In its “Old to New Mini-Split Models” table, LENNOX sets each MPB against an MPC, a 3rd generation: the MPB012S4S-1P against the MPC012S4S-1P, for example. The B in the number means 2nd generation.

LENNOX, bulletin 211020 (July 2022); bulletins 210863, p. 2, and 211038.
4 heads

One MPB 12,000, four possible heads

The LENNOX bulletin pairs the same outdoor unit with an MWMA wall head, an M22A cassette, an MFMA console or an MMDB ducted unit, each with its own AHRI rating.

LENNOX, bulletin 210863 (December 2020).
46%

At -25 °C, the MPB 12,000 still heats

Its table gives 6,320 BTU/h at -25 °C (-13 °F), 46% of what it gives at 8.3 °C (13,660). It is the coldest row LENNOX publishes for it.

LENNOX, bulletin 210863, p. 27.
03 · Warranty and LogisVert

Your MPB: what LENNOX covers, and LogisVert

The warranty is read in the LENNOX certificates; the LogisVert amount, on Hydro-Québec’s list, as carried on our product pages.

What LENNOX covers on an MPB

  • 12 years on parts and 12 years on the compressor in Québec, for an installation on or after March 1, 2017.
  • No registration needed: the certificate names Québec.
  • The MWMA head also gets 12 years on parts.
  • The extension stays with the original owner; the basic warranty (7 years compressor, 5 years parts) follows subsequent owners.
  • Labour is not covered by LENNOX.

LENNOX, Extended Limited Warranty EW900011-01 (January 1, 2026); Basic Limited Warranty W900004-02 (November 11, 2025); bulletin 210863, p. 5.

Why no amount: the LogisVert guide requires an ENERGY STAR certified unit, and none of the four MPB AHRI numbers is in the ENERGY STAR registry checked on October 28, 2026. Amounts read from our product pages (Hydro-Québec list of Oct. 6, 2026, latest check); indicative amounts: only Hydro-Québec confirms the assistance granted. Our LogisVert page.

04 · The technician’s corner

The pairings LENNOX prints

Your MPB doesn’t necessarily have a wall head. Here is every pairing in bulletin 210863, with its AHRI rating: handy to find the number of a system already in place.

OutdoorHeadTypeCoolingSEER · EER · HSPFHeating 8.3 · -8.3 °CAHRI
MPB009S4S-1PMWMA009S4-2P · -3PWall9,000 BTU/h23.5 · 14.9 · 10.89,800 · 5,80010056170 · 201796630
MPB009S4S-1PM22A009S4-1P2 × 2 cassette9,000 BTU/h20 · 13 · 10.510,000 · 5,80010058830
MPB009S4S-1PMMDB009S4-2PDucted9,000 BTU/h20.5 · 13.5 · 11.510,000 · 6,80010528563
MPB012S4S-1PMWMA012S4-2P · -3PWall12,000 BTU/h22.7 · 13.7 · 1112,000 · 7,70010056172 · 201796631
MPB012S4S-1PM22A012S4-1P2 × 2 cassette12,000 BTU/h21.5 · 14 · 10.512,000 · 7,50010058832
MPB012S4S-1PMFMA012S4Floor console12,000 BTU/h20.5 · 13 · 1012,000 · 7,200206188242
MPB012S4S-1PMMDB012S4-2PDucted12,000 BTU/h21.5 · 12.5 · 11.512,000 · 7,20010528564
MPB018S4S-1PMWMA018S4-2PWall18,000 BTU/h21 · 13 · 10.418,000 · 11,40010056174
MPB018S4S-1PM22A018S4-1P2 × 2 cassette18,000 BTU/h20 · 12.5 · 10.318,000 · 12,00010058834
MPB018S4S-1PMMDB018S4-2PDucted18,000 BTU/h19 · 12.5 · 10.518,000 · 12,00010528565
MPB024S4S-1PMWMA024S4-2PWall24,000 BTU/h20.7 · 13.7 · 11.525,000 · 15,30010056176
MPB024S4S-1PM33A024S4-1P3 × 3 cassette24,000 BTU/h20 · 12.5 · 10.524,400 · 15,80010058836
MPB024S4S-1PMMDB024S4-2PDucted24,000 BTU/h21.5 · 12.5 · 1124,400 · 16,00010528566

LENNOX bulletin 210863 (December 2020). The wall units on our product pages use the MWMA -3P at 9,000 and 12,000. Factory charge covers 25 ft of line; beyond that, 0.16 oz of R-410A per foot (0.32 oz for the 24,000).

05 · Questions

What people ask us about the MPB

MPB or MLA: which heats more in the cold?

The MLA, at all four sizes, according to the LENNOX tables: at -15 °C, the 12,000 gives 12,100 BTU/h against 9,130 for the MPB. It also heats lower: down to -30 °C, against -25 °C for the MPB. The MPB has the better HSPF rating at all four sizes.

Does my MWMA head go with an MPB as with an MLA?

Yes: LENNOX publishes an AHRI rating for each series with the same head, at each size. At 9,000 and 12,000, our product pages use the MWMA -3P; at 18,000 and 24,000, the -2P. We check your head’s number on site.

What is the MPB’s SEER2?

LENNOX doesn’t publish one: the December 2020 bulletin rates the MPB in SEER, EER and HSPF. We don’t convert these numbers to SEER2, and we don’t compare them with the SEER2 of the R-32 wall units.

How cold does the MPB heat?

LENNOX gives it a heating range of -13 to 86 °F, i.e. -25 to 30 °C, and its table stops at -25 °C. At Montréal-Trudeau, about 12 nights a year drop below -20 °C, and the 1991-2020 low is -31.8 °C: keep your existing heating for those nights.

My MPB has a cassette or a ducted unit: is that normal?

Yes. The LENNOX bulletin pairs the same outdoor unit with M22A and M33A cassettes, an MFMA console and MMDB ducted units. The technician’s corner, below, gives the AHRI rating of each pairing.

Do I need to register the warranty in Québec?

No. LENNOX extended warranty EW900011-01 names Québec among the places where registration is not required: an MPB installed on or after March 1, 2017 gets 12 years on parts and 12 years on the compressor. Labour is not covered by LENNOX, and the extension stays with the original owner.

Does the MPB qualify for LogisVert?

No. The LogisVert guide requires an ENERGY STAR certified unit, and none of the four AHRI numbers of our MPB is in the ENERGY STAR registry (checked October 28, 2026). Only Hydro-Québec confirms the assistance granted.

Do you repair MPB units?

Yes. See our LENNOX repair page, or send us a photo of the outdoor unit’s nameplate.

Sold and installed by AirGreen

Your MPB, or the one you are considering: AirGreen comes and looks.

We look at the room, the head already on your wall and where the outdoor unit goes, then give you a clear quote, with the unit’s AHRI number.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil: a licensed partner.
Free estimateAt your home, no obligation.
LogisVert on the quoteAHRI number and indicative amount when the unit qualifies.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.

Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.

AirGreenLENNOX

Sources checked October 28, 2026

  1. LENNOX, MPB bulletin 210863, “Single Zone Heat Pump Systems”, December 2020: legend, operating ranges, AHRI ratings and pairings, heating tables, sound, weights, charge, piping, electrical data, warranty.
  2. LENNOX, MLA/MLB bulletin 210861, May 2021: MLA AHRI ratings, heating tables, sound, weights, charge, piping and electrical data (comparison).
  3. LENNOX, “Old to New Mini-Split Models” table, bulletin 211020, July 2022; MPC bulletin 211038, April 2024 (3rd generation).
  4. LENNOX, Basic Limited Warranty W900004-02 (November 11, 2025) and Extended Limited Warranty EW900011-01 (January 1, 2026).
  5. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), updated October 28, 2026, and NEEP, Cold Climate Air Source Heat Pump List, checked October 28, 2026: AHRI 201796630, 201796631, 10056174 and 10056176 absent from both.
  6. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026; eligible heat pump list of October 6, 2026 (latest check).
  7. Environment and Climate Change Canada, Canadian Climate Normals 1991-2020, Montréal-Trudeau (7025250).

LogisVert amounts are indicative: only Hydro-Québec confirms the assistance granted. Price on quote. Free in-home estimate.