The MWLD has a base pan heater against ice
LENNOX fits it to stop ice building up in the base of the outdoor unit while heating. NEEP lists it at 150 W.
LENNOX, form 211080, p. 5; NEEP record 382727.LENNOX gives the MWLD a heating range down to -30 °C. At that temperature the 12,000 still has 6,200 to 6,800 BTU/h, depending on the LENNOX source. And at -15 °C its certified rating is 9,000 BTU/h, not the 14,400 in its technical table. We show you both, size by size.
From 9,000 to 24,000 BTU/h. Open a product page for the AHRI number, dimensions and the indicative LogisVert amount.
Two LENNOX sources side by side: the certified rating (standard test, the one ENERGY STAR and Hydro-Québec use) and the technical table in form 211080. Frequencies come from the Montréal-Trudeau climate normals.
Certified rating: measured under the AHRI standard test at 17 °F and 5 °F. Technical table: LENNOX form 211080, 21 °C indoors, compressor speed not stated. Below -15 °C there is no certified rating.
Certified rating (ENERGY STAR) at -15 °C (5 °F), i.e. 75% of its 12,000 BTU/h rating at 8.3 °C.
The LENNOX technical table gives 14,400 BTU/h at the same temperature; it does not state the compressor speed. At the visit, we start from the certified rating.
Certified or registry-declared valueLENNOX technical tableRating at 8.3 °C
January average low at Montréal-Trudeau: -13.5 °C.
Same MWMD indoor head, same certified ratings. LENNOX stops the MWPD at -5 °F (-20.6 °C), and its sheet does not mention a base pan heater.
Pink rows are the differences. Tables: LENNOX forms 211080 and 211081; certified ratings: ENERGY STAR (Oct. 28, 2026). At Montréal-Trudeau, about 12 nights a year drop below -20 °C, and about one night every five years below -30 °C (1991-2020 normals).
LENNOX fits it to stop ice building up in the base of the outdoor unit while heating. NEEP lists it at 150 W.
LENNOX, form 211080, p. 5; NEEP record 382727.Lennox.com advertises 100% capacity at 5 °F (-15 °C). The LENNOX table confirms it from the 9,000 to the 18,000. The certified rating gives the 12,000 9,000 BTU/h: 75% of its rating at 8.3 °C.
LENNOX, MWLD page and form 211080, p. 12-18; ENERGY STAR 3891262.Defrost starts on its own when frost covers the outdoor coil. Meanwhile the outdoor fan stops and the indoor head drops to its lowest speed.
LENNOX, form 211080, p. 5.Amounts from our product pages, matching Hydro-Québec’s list at our last check (list of October 6, 2026). Indicative amounts: only Hydro-Québec confirms the assistance granted.
LogisVert residential participation guide, version 1.10, September 15, 2026. Our LogisVert page.
LENNOX form 211080 (Aug. 2025). Sound is the outdoor unit in cooling mode; LENNOX does not publish heating sound.
| Size | AHRI | Outdoor sound | Max. piping | Max. height | Liquid · gas | MCA / MOCP |
|---|---|---|---|---|---|---|
| 9,000 | 216411305 | 45 dB(A) | 66 ft | 49 ft | 1/4 · 3/8 in. | 12 / 20 A |
| 12,000 | 216411306 | 46 dB(A) | 66 ft | 49 ft | 1/4 · 3/8 in. | 12.5 / 20 A |
| 15,000 | 216411307 | 48 dB(A) | 98 ft | 66 ft | 1/4 · 1/2 in. | 21 / 30 A |
| 18,000 | 216411308 | 51 dB(A) | 98 ft | 66 ft | 1/4 · 1/2 in. | 21 / 30 A |
| 24,000 | 216411309 | 54 dB(A) | 98 ft | 66 ft | 1/4 · 5/8 in. | 21 / 30 A |
Minimum line: 9.8 ft. Factory charge covers 24.6 ft of line; beyond that, 0.16 oz of R-32 per foot (LENNOX installation manual, December 2024).
Reference points from the Québec.ca scale (“Noise measurement”, 2022). Order of magnitude only: distance and place change the reading.
Yes: LENNOX gives it a heating range of -22 to 75 °F (-30 to 24 °C). At -30 °C, the 12,000 delivers 6,200 BTU/h according to the LENNOX table and 6,800 BTU/h according to what LENNOX declares to NEEP, a little over half its rating at 8.3 °C. Keep your baseboards as backup for those nights.
Both come from LENNOX. The certified rating (9,000 BTU/h for the 12,000) comes from the standard test; it is the one ENERGY STAR and Hydro-Québec use. The technical table (14,400 BTU/h) does not state the compressor speed. At the visit, we start from the certified rating.
At the same size they share the indoor head and the certified ratings. The MWPD stops at -20.6 °C (-5 °F); the MWLD keeps going to -30 °C and has a base pan heater. At Montréal-Trudeau, about 12 nights a year drop below -20 °C (1991-2020 normals).
No. LENNOX extended warranty EW900011-01 names Québec among the places where registration is not required: the MWLD gets 12 years on parts and 12 years on the compressor in total. Labour is not covered by LENNOX, and the extended warranty stays with the original owner.
No. The LogisVert guide (version 1.10, September 15, 2026) requires an outdoor unit of at least 12,000 BTU/h nominal. The 12,000 to 24,000 MWLD carried an indicative amount on Hydro-Québec’s list at our last check.
Yes. The MWMD indoor head has built-in Wi-Fi and comes with a wireless remote. Wired wall controls are available as options.
The LENNOX sheet allows up to 98 ft of piping and 66 ft of height difference for the 15,000 to 24,000, 66 ft and 49 ft for the 9,000 and 12,000. Placement is decided on site, with your city’s rules.
We don’t guess it over the phone. We come and look at the room, the insulation, the windows and the heating in place, then we suggest the size. The estimate is free.
We come and see the room, choose the size with you and give you a clear quote, with the AHRI number and the indicative LogisVert amount when the unit qualifies.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.
LogisVert amounts are indicative: only Hydro-Québec confirms the assistance granted. Price on quote. Free in-home estimate.