Does the ARTCOOL Deluxe really heat at −35°C?
Yes: LG publishes a heating range from −35°C to 18.3°C, and the NEEP list gives a maximum output at −35°C of 7,700 BTU/h for the 9,000 and 9,100 BTU/h for the 12,000.
Do I still need backup heat with a Deluxe?
It depends on the room’s heat loss. Down to −25°C the Deluxe delivers its rated output (11,000 BTU/h or 13,000 BTU/h); at −35°C, 70% of it. We work it out during the visit.
Why does the Deluxe 9,000 get no LogisVert amount?
Hydro-Québec requires at least 12,000 BTU/h of rated cooling capacity. The 9,000 is Cold Climate certified but too small for the program.
Where does the $1,008 for the 12,000 come from?
From its certified rated output at −8°C: 8,400 BTU/h, at $120 per 1,000 BTU/h. Hydro-Québec does not count how the unit holds up below −8°C.
Is a 20 m line set enough?
For a head mounted close to the outdoor unit, yes. If the room is far from an outside wall, the Mirror and DUALCOOL take 25 m at 9,000 and 12,000; we measure the run during the visit.
Deluxe or R-410A DUALCOOL PRESTIGE: which one?
Their certified SEER2, EER2 and HSPF2 (region IV) are identical at the same capacity. The Deluxe heats down to −35°C instead of −25°C, and keeps 13,000 BTU/h at −25°C on the 12,000, versus 9,640 BTU/h.